Single‐loop coil concepts for intravascular magnetic resonance imaging

Compared with other coil designs that have been investigated for intravascular use, the single‐loop coil can be designed with a very small diameter for insertion into small vessels and with a longitudinal extent over several centimeters for multislice imaging. If it designed to be expandable inside the target vessel, then it combines these features with increased signal‐to‐noise ratio (SNR) and penetration depth. Expandable single‐loop coils that are capable of meeting these requirements were developed and integrated into two different commercial catheter‐based delivery systems: a self‐expandable, single‐loop made from NiTinol and a single‐loop coil mounted on an inflatable balloon. The influence of a small‐diameter coaxial cable for remote tuning and matching on the coil performance was investigated. Calculations showed the dependence of the signal on the separation between the conductors. The comparison of both catheter approaches in in vitro flow experiments and in an in vivo pig experiment revealed the influence of pulsatile flow on image quality during intravascular imaging with these designs. Magn Reson Med 41:751–758, 1999. © 1999 Wiley‐Liss, Inc.

[1]  J. Debatin,et al.  Active MR visualization of a vascular guidewire in vivo , 1998, Journal of magnetic resonance imaging : JMRI.

[2]  J F Debatin,et al.  Intravascular MR imaging of atherosclerotic plaque: ex vivo analysis of human femoral arteries with histologic correlation. , 1997, Radiology.

[3]  Ogan Ocali,et al.  Intravascular magnetic resonance imaging using a loopless catheter antenna , 1997, Magnetic resonance in medicine.

[4]  P A Bottomley,et al.  High resolution intravascular MRI and MRS by using a catheter receiver coil , 1996, Magnetic resonance in medicine.

[5]  V. Fuster,et al.  Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. , 1996, Circulation.

[6]  A. Cribier,et al.  Effects of prolonged sequential balloon inflations on results of coronary angioplasty. , 1996, The American journal of cardiology.

[7]  R M Henkelman,et al.  Intravascular MR imaging in a porcine animal model , 1994, Magnetic resonance in medicine.

[8]  R. Erbel,et al.  Continuous coronary perfusion balloon catheters in coronary dissections after percutaneous transluminal coronary angioplasty. Acute clinical results and 6-months follow-up. , 1994, European heart journal.

[9]  F A Jolesz,et al.  Prototype miniature endoluminal MR imaging catheter. , 1993, Journal of vascular and interventional radiology : JVIR.

[10]  D B Plewes,et al.  MR imaging of blood vessels with an intravascular coil , 1992, Journal of magnetic resonance imaging : JMRI.

[11]  J L Duerk,et al.  Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging , 1992, Magnetic resonance in medicine.

[12]  D. Traficante Impedance: What it is, and why it must be matched , 1989 .

[13]  J. Martin,et al.  Inflatable surface coil for MR imaging of the prostate. , 1988, Radiology.

[14]  A. Koretsky,et al.  Loading characteristics of surface coils constructed from wire and foil , 1986 .

[15]  L Axel,et al.  Noise performance of surface coils for magnetic resonance imaging at 1.5 T. , 1985, Medical physics.

[16]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[17]  R. Balaban,et al.  In Vivo 31P Nuclear Magnetic Resonance Measurements in Canine Heart Using a Catheter‐Coil , 1984, Circulation research.

[18]  P. Lauterbur,et al.  The sensitivity of the zeugmatographic experiment involving human samples , 1979 .

[19]  David G. Gadian,et al.  Radiofrequency losses in NMR experiments on electrically conducting samples , 1979 .