Thickness characteristics and improved surface adhesion of a polypyrrole actuator by analysis of polymerization process

Characterizing electrochemical polymerization of polypyrrole film on a substrate depends on many parameters. Among them, potential difference and cumulative charges play important role. The level of potential difference affects the quality of the polypyrrole. On the contrary, cumulative charge affects the thickness of the polypyrrole. The substrate surface is adjusted physically and chemically by treating with sandblasting and the addition of thiol for surface adhesion improvement. Experimental results show that the sandblasted and thiol treated substrate provides better adhesion than non-sandblasted and non-thiol treated substrate.

[1]  Ingemar Lundström,et al.  Perpendicular Actuation with Individually Controlled Polymer Microactuators , 2001 .

[2]  Ingemar Lundström,et al.  The Cell Clinic: Closable Microvials for Single Cell Studies , 2002 .

[3]  Şahin Yildirim,et al.  Design of neural networks model for transmission angle of a modified mechanism , 2005 .

[4]  E. Smela Microfabrication of PPy microactuators and other conjugated polymer devices , 1999 .

[5]  E. Smela,et al.  Microfabricating conjugated polymer actuators. , 2000, Science.

[6]  Shang Hyon Shin,et al.  FEM analysis of plasticity-induced error on measurement of welding residual stress by the contour method , 2005 .

[7]  I. Lundström,et al.  Microrobots for micrometer-size objects in aqueous media: potential tools for single-cell manipulation. , 2000, Science.

[8]  Shuxiang Guo,et al.  Micro active guide wire catheter system-Characteristic evaluation, electrical model and operability evaluation of micro active catheter , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[9]  Elisabeth Smela,et al.  Surprising Volume Change in PPy(DBS): An Atomic Force Microscopy Study , 1999 .

[10]  Ingemar Lundström,et al.  Polypyrrole micro actuators , 1999 .

[11]  Elisabeth Smela,et al.  ON-CHIP MICROELECTRODES FOR ELECTROCHEMISTRY WITH MOVEABLE PPY BILAYER ACTUATORS AS WORKING ELECTRODES , 1999 .

[12]  Shuxiang Guo,et al.  Development of a new type of capsule micropump , 1999, Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C).

[13]  Seunghak Lee,et al.  Design and fabrication of the Locomotive Mechanism for Capsule Endoscopes Using Shape Memory Alloys (SMA) , 2003 .