In vitro and in vivo effects within the coronary sinus of nonarcing and arcing shocks using a new system of low-energy DC ablation.

DC shocks within the coronary sinus have been abandoned because of the risk of cardiac rupture and tamponade. Catheter ablation using DC energy to electrodes straddling the ostium of the coronary sinus, when used clinically, has been reported to result in cardiac tamponade in as many as 16% of patients. A new system of energy delivery maximizes voltage while decreasing the undesirable effects caused by barotrauma. This system includes 1) a low-energy ablation power supply with a brief time-constant capacitive discharge that delivers up to 40 J and 3,000 V and 2) a low-energy ablation catheter with a contoured distal electrode. We performed in vitro and in vivo studies of this new system and compared arcing shocks with nonarcing shocks. Ablations were performed using unipolar distal shocks (D) and unipolar shocks to both electrodes made electrically common (P-D). In vitro studies were done in a large tank filled with physiological saline while recording voltage, current, and pressure. High-speed cinematography (32,000 frames/sec) of shocks of 10-40 J permitted detailed analysis of the vapor globe. Anodal shocks of less than 20 J showed no arcing or only minimal vapor globe formation. For D and P-D anodal shocks of 40 J, the diameters of the vapor globe were 31 and 22 mm, respectively, corresponding to pressure recordings of 11 and 4.9 atm. The pressure rise lasted less than 50 mu sec. In vivo studies involved 18 dogs that received nonarcing shocks (one to six shocks of 15 J) and 18 dogs that received arcing shocks (one to three shocks of 40 J). Each group was divided between D and P-D shocks; catheter ablation was performed at a mean +/- SEM distance of 2.94 +/- 0.92 cm within the coronary sinus. All dogs tolerated the procedure without cardiac rupture or tamponade. When killed 2-4 days later, the dogs had edema and hyperemia or hemorrhage in the area of the coronary sinus. We compared the effects of multiple (three to six) nonarcing shocks with the effects of one to three arcing shocks. Disruption or rupture of the coronary sinus within the epicardial fat space occurred in two of 12 dogs (17%) with multiple nonarcing shocks but in 13 of 18 dogs (72%) with arcing shocks (p less than 0.003). Occlusion of the coronary sinus occurred in two of 12 dogs (17%) with multiple nonarcing shocks and in nine of 18 dogs (50%) with arcing shocks (p less than 0.06).(ABSTRACT TRUNCATED AT 400 WORDS)

[1]  M. Silver,et al.  The functional anatomy of the human coronary sinus. , 1988, American heart journal.

[2]  R. Winkle,et al.  Transvenous catheter ablation of extranodal accessory pathways. , 1988, Journal of the American College of Cardiology.

[3]  S. Huang,et al.  Short- and long-term effects of transcatheter ablation of the coronary sinus by radiofrequency energy. , 1988, Circulation.

[4]  F. Morady Catheter ablation of accessory pathways. , 1990, Cardiology clinics.

[5]  R. Lazzara,et al.  Localization of Left Free‐Wall and Posteroseptal Accessory Atrioventricular Pathways by Direct Recording of Accessory Pathway Activation , 1989, Pacing and clinical electrophysiology : PACE.

[6]  H. Greene,et al.  Catheter-mediated electrical ablation of the posterior septum via the coronary sinus: electrophysiologic and histologic observations in dogs. , 1985, Circulation.

[7]  R. Lazzara,et al.  New catheter technique for recording left free-wall accessory atrioventricular pathway activation. Identification of pathway fiber orientation. , 1988, Circulation.

[8]  J. Fisher,et al.  Attempted nonsurgical electrical ablation of accessory pathways via the coronary sinus in the Wolff-Parkinson-White syndrome. , 1984, Journal of the American College of Cardiology.

[9]  W C Sealy,et al.  The preexcitation syndromes. , 1978, Progress in cardiovascular diseases.

[10]  J. Fisher,et al.  Evaluation of a Catheter Technique for Ablation of Accessory Pathways Near the Coronary Sinus Using a Canine Model , 1983, Circulation.

[11]  H. Wellens,et al.  The Anatomical Substrates of Wolff-Parkinson-White Syndrome , 1978, Circulation.

[12]  T. Ryan,et al.  Coronary sinus occlusion pressure and its relation to intracardiac pressure. , 1985, The American journal of cardiology.

[13]  L. Giorgi,et al.  Right coronary spasm complicating electrode catheter ablation of a right lateral accessory pathway. , 1985, Journal of the American College of Cardiology.

[14]  K. Kuck,et al.  Radiofrequency current directed across the mitral anulus with a bipolar epicardial-endocardial catheter electrode configuration in dogs. , 1988, Circulation.

[15]  J. Gallagher,et al.  The surgical anatomy of Kent bundles based on electrophysiological mapping and surgical exploration. , 1978, The Journal of thoracic and cardiovascular surgery.

[16]  George A. Johnson,et al.  Developments, complications and limitations of catheter-mediated electrical ablation of posterior accessory atrioventricular pathways. , 1988, The American journal of cardiology.

[17]  G. Guiraudon,et al.  Surgical repair of Wolff-Parkinson-White syndrome: a new closed-heart technique. , 1984, The Annals of thoracic surgery.

[18]  M. Haissaguerre,et al.  Closed-chest ablation of left lateral atrioventricular accessory pathways. , 1989, European heart journal.

[19]  M. Chin,et al.  Catheter ablation of accessory pathways using radiofrequency energy in the canine coronary sinus. , 1989, Journal of the American College of Cardiology.

[20]  R. Hauer,et al.  Electrical catheter ablation in the left and right ventricular wall in dogs: relation between delivered energy and histopathologic changes. , 1986, Journal of the American College of Cardiology.

[21]  E. Rowland,et al.  Catheter Ablation Without Fulguration: Design and Performance of a New System , 1989, Pacing and clinical electrophysiology : PACE.

[22]  A. Becker,et al.  The wolff‐parkinson‐white syndrome and its anatomical substrates , 1981, The Anatomical record.

[23]  M. Haissaguerre,et al.  Catheter ablation of accessory pathways with a direct approach. Results in 35 patients. , 1988, Circulation.

[24]  E. Rowland,et al.  Impedance Changes During Catheter Ablation and Their Relationship to Electrical Arcing and Clinical Efficacy , 1989, Pacing and clinical electrophysiology : PACE.

[25]  J. Mazzara,et al.  Angiographic demonstration of coronary sinus thrombosis: a potential consequence of trauma to the coronary sinus. , 1982, Catheterization and cardiovascular diagnosis.

[26]  F.A.C.S. F.R.C.S Eng. F.R.C.S. ED. Wallace A. McAlpine M.D. Heart and Coronary Arteries , 1975, Springer Berlin Heidelberg.

[27]  A. Kadish,et al.  Long-term results of catheter ablation of a posteroseptal accessory atrioventricular connection in 48 patients. , 1989, Circulation.