Texture-preserving Bayesian image reconstruction for low-dose CT

Markov random field (MRF) model has been widely used in Bayesian image reconstruction to reconstruct piecewise smooth images in the presence of noise, such as in low-dose X-ray computed tomography (LdCT). While it can preserve edge sharpness via edge-preserving potential function, its regional smoothing may sacrifice tissue image textures, which have been recognized as useful imaging biomarkers, and thus it compromises clinical tasks such as differentiating malignant vs. benign lesions, e.g., lung nodule or colon polyp. This study aims to shift the edge preserving regional noise smoothing paradigm to texture-preserving framework for LdCT image reconstruction while retaining the advantage of MRF’s neighborhood system on edge preservation. Specifically, we adapted the MRF model to incorporate the image textures of lung, bone, fat, muscle, etc. from previous full-dose CT scan as a priori knowledge for texture-preserving Bayesian reconstruction of current LdCT images. To show the feasibility of proposed reconstruction framework, experiments using clinical patient scans (with lung nodule or colon polyp) were conducted. The experimental outcomes showed noticeable gain by the a priori knowledge for LdCT image reconstruction with the well-known Haralick texture measures. Thus, it is conjectured that texture-preserving LdCT reconstruction has advantages over edge-preserving regional smoothing paradigm for texture-specific clinical applications.

[1]  J H Siewerdsen,et al.  dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images , 2014, Physics in medicine and biology.

[2]  P. Lambin,et al.  Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach , 2014, Nature Communications.

[3]  Patrick J. La Rivière,et al.  Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing , 2005, IEEE Transactions on Medical Imaging.

[4]  Zhengrong Liang,et al.  Fast and Adaptive Detection of Pulmonary Nodules in Thoracic CT Images Using a Hierarchical Vector Quantization Scheme , 2015, IEEE Journal of Biomedical and Health Informatics.

[5]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[6]  Jianhua Ma,et al.  Extracting Information From Previous Full-Dose CT Scan for Knowledge-Based Bayesian Reconstruction of Current Low-Dose CT Images , 2016, IEEE Transactions on Medical Imaging.

[7]  V. Goh,et al.  Assessment of primary colorectal cancer heterogeneity by using whole-tumor texture analysis: contrast-enhanced CT texture as a biomarker of 5-year survival. , 2013, Radiology.

[8]  Jie Tang,et al.  Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitions , 2009, Medical Imaging.

[9]  Zhou Yu,et al.  Prediction coefficient estimation in Markov random fields for iterative x-ray CT reconstruction , 2012, Medical Imaging.

[10]  Jing Wang,et al.  Deriving adaptive MRF coefficients from previous normal-dose CT scan for low-dose image reconstruction via penalized weighted least-squares minimization. , 2014, Medical physics.

[11]  Robert M. Haralick,et al.  Textural Features for Image Classification , 1973, IEEE Trans. Syst. Man Cybern..