Ultrasound-mediated transdermal transport of insulin in vitro through human skin using novel transducer designs.

Recent studies have shown that ultrasound (US)-mediated transdermal drug delivery offers a promising potential for noninvasive drug administration. The purpose of this study was to improve low-frequency (20 kHz) US methods for enhancing the transport of insulin in vitro across human skin. The feasibility of using US produced by small, lightweight novel transducers was explored for enhancing the transport of insulin across skin. Previous investigators have used US devices such as large, heavy sonicators or commercially obtained transducers for this type of research. The experiments carried out in this study used two low-profile novel US transducer arrays, the stack and standard array, for improved transport of insulin. The stack array generated a spatial peak temporal peak intensity (I(SPTP)) of 15.4 +/- 0.6 mW/cm(2) and the standard array had an I(SPTP) of 173.7 +/- 1.2 mW/cm(2). Spectrophotometeric absorption techniques were used for determining insulin transport in vitro across human skin. Compared with passive transmission (4.1 +/- 0.5 U) over an exposure period of 1 h, the standard array facilitated over a sevenfold increase in the noninvasive transdermal transport of Humulin R insulin (45.9 +/- 12.9 U). Using Humalog insulin with the standard array, there was a fourfold increase in the US-facilitated transmission over that in the control. These promising results indicate that low-frequency US can be used in a practical device for enhanced transport across the stratum corneum.

[1]  S. Mitragotri,et al.  Synergistic effects of chemical enhancers and therapeutic ultrasound on transdermal drug delivery. , 1996, Journal of pharmaceutical sciences.

[2]  F. Patat,et al.  Transdermal delivery of insulin using low frequency ultrasound , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[3]  S. Mitragotri,et al.  Low-frequency sonophoresis: a review. , 2004, Advanced drug delivery reviews.

[4]  R.E. Newnham,et al.  Composite piezoelectric transducer with truncated conical endcaps "cymbal" , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  J. Chappelow,et al.  Defects generated in human stratum corneum specimens by ultrasound. , 1998, Ultrasound in medicine & biology.

[6]  J Kost,et al.  Low‐Frequency Sonophoresis: A Noninvasive Method of Drug Delivery and Diagnostics , 2000, Biotechnology progress.

[7]  N. Byl,et al.  The effects of phonophoresis with corticosteroids: a controlled pilot study. , 1993, The Journal of orthopaedic and sports physical therapy.

[8]  M. Takada,et al.  Effect of pulsed output ultrasound on the transdermal absorption of indomethacin from an ointment in rats. , 1997, Biological & pharmaceutical bulletin.

[9]  J Kost,et al.  Effect of ultrasound on transdermal drug delivery to rats and guinea pigs. , 1989, The Journal of clinical investigation.

[10]  K. Tachibana,et al.  Transdermal delivery of insulin by ultrasonic vibration , 1991, The Journal of pharmacy and pharmacology.

[11]  M. Prausnitz Reversible skin permeabilization for transdermal delivery of macromolecules. , 1997, Critical reviews in therapeutic drug carrier systems.

[12]  K. Tachibana Transdermal Delivery of Insulin to Alloxan-Diabetic Rabbits by Ultrasound Exposure , 1992, Pharmaceutical Research.

[13]  K. Alberti,et al.  World book of diabetes in practice , 1986 .

[14]  K. Tachibana,et al.  Application of Ultrasound Energy as a New Drug Delivery System , 1998, Nihon yakurigaku zasshi. Folia pharmacologica Japonica.

[15]  R. Guy,et al.  Sonophoresis. I. The Use of High-Frequency Ultrasound to Enhance Transdermal Drug Delivery , 1992, Pharmaceutical Research.

[16]  M. Takada,et al.  External control of drug release and penetration. VI. Enhancing effect of ultrasound on the transdermal absorption of indomethacin from an ointment in rats. , 1992, Chemical & pharmaceutical bulletin.

[17]  S. Mitragotri,et al.  Ultrasound-mediated transdermal protein delivery , 1995, Science.

[18]  K. Tachibana,et al.  Scanning electron microscopic evaluation of the skin surface after ultrasound exposure , 1997, The Anatomical record.

[19]  R.E. Newnham,et al.  Finite element analysis of the cymbal-type flextensional transducer , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  S. Mitragotri,et al.  An explanation for the variation of the sonophoretic transdermal transport enhancement from drug to drug. , 1997, Journal of pharmaceutical sciences.

[21]  R. Guy,et al.  Sonophoresis. II. Examination of the Mechanism(s) of Ultrasound-Enhanced Transdermal Drug Delivery , 1992, Pharmaceutical Research.

[22]  M. Hippius,et al.  In vitro investigations of drug release and penetration--enhancing effect of ultrasound on transmembrane transport of flufenamic acid. , 1998, Experimental and toxicologic pathology : official journal of the Gesellschaft fur Toxikologische Pathologie.

[23]  K. Shung,et al.  Hydrogels with enhanced mass transfer for transdermal drug delivery. , 1996, Journal of pharmaceutical sciences.

[24]  M. Prausnitz,et al.  A practical assessment of transdermal drug delivery by skin electroporation. , 1999, Advanced drug delivery reviews.

[25]  F. Montorsi,et al.  Transdermal electromotive multi-drug administration for Peyronie's disease: preliminary results. , 2000, Journal of andrology.