The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty
暂无分享,去创建一个
R Baker | D. Beverland | R. Baker | D Bennett | D E Beverland | J F Orr | D. Bennett | J. Orr
[1] Duncan Dowson,et al. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints , 1985 .
[2] J. Fisher,et al. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[3] H B Skinner,et al. Pathokinesiology and Total Joint Arthroplasty , 1993, Clinical orthopaedics and related research.
[4] D. Tabor,et al. Friction and molecular structure: the behaviour of some thermoplastics , 1972, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.
[5] B. Morrey,et al. Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.
[6] Martin Bland,et al. An Introduction to Medical Statistics , 1987 .
[7] J H Dumbleton,et al. Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement Prostheses , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[8] M P Kadaba,et al. Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[9] Brian J. Edwards,et al. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene , 1997 .
[10] S. Smith,et al. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[11] J. Archard. Contact and Rubbing of Flat Surfaces , 1953 .
[12] J. Fisher,et al. Biological reactions to wear debris in total joint replacement , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[13] D. Howie,et al. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. , 1988, The Journal of bone and joint surgery. American volume.
[14] W H Harris,et al. Loci of movement of selected points on the femoral head during normal gait. Three-dimensional computer simulation. , 1996, The Journal of arthroplasty.
[15] W. Capello,et al. Periprosthetic Bone Loss in Total Hip Arthroplasty (THA) , 1998 .
[16] R Baker,et al. Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation. , 2000, The Journal of arthroplasty.
[17] M. Ritter,et al. Measurement of polyethylene thickness in total hip arthroplasty. A technique analysis. , 1994, The Journal of arthroplasty.
[18] M. Semlitsch,et al. Reactions of the articular capsule to wear products of artificial joint prostheses. , 1977, Journal of biomedical materials research.
[19] J Fisher,et al. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[20] J. Fisher,et al. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements , 1999, Journal of materials science. Materials in medicine.
[21] J. K. Lancaster,et al. MATERIAL-SPECIFIC WEAR MECHANISMS : RELEVANCE TO WEAR MODELLING , 1990 .
[22] V. Saikko,et al. Type of motion and lubricant in wear simulation of polyethylene acetabular cup , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[23] C. Bragdon,et al. The Importance of Multidirectional Motion on the Wear of Polyethylene , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[24] R. Brooks,et al. The effects of the concentration of high-density polyethylene particles on the bone-implant interface. , 2000, The Journal of bone and joint surgery. British volume.
[25] A. Wang,et al. The significance of nonlinear motion in the wear screening of orthopaedic implant materials , 1997 .