Volume Catheter Parallel Conductance Varies Between End-Systole and End-Diastole

In order for the conductance catheter system to accurately measure instantaneous cardiac blood volume, it is necessary to determine and remove the contribution from parallel myocardial tissue. In previous studies, the myocardium has been treated as either purely resistive or purely capacitive when developing methods to estimate the myocardial contribution. We propose that both the capacitive and the resistive properties of the myocardium are substantial, and neither should be ignored. Hence, the measured result should be labeled admittance rather than conductance. We have measured the admittance (magnitude and phase angle) of the left ventricle in the mouse, and have shown that it is measurable and increases with frequency. Further, this more accurate technique suggests that the myocardial contribution to measured admittance varies between end-systole and end-diastole, contrary to previous literature. We have tested these hypotheses both with numerical finite-element models for a mouse left ventricle constructed from magnetic resonance imaging images, and with in vivo admittance measurements in the murine left ventricle. Finally, we propose a new method to determine the instantaneous myocardial contribution to the measured left ventricular admittance that does not require saline injection or other intervention to calibrate.

[1]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[2]  D. Kass,et al.  Estimation of parallel conductance by dual-frequency conductance catheter in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[3]  Chia-Ling Wei,et al.  Design of instrumentation and data-acquisition system for complex admittance measurement. , 2004, Biomedical sciences instrumentation.

[4]  A A Shoukas,et al.  Does volume catheter parallel conductance vary during a cardiac cycle? , 1990, The American journal of physiology.

[5]  佐川 喜一,et al.  Cardiac contraction and the pressure-volume relationship , 1988 .

[6]  W L Maughan,et al.  Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man. , 1988, Catheterization and cardiovascular diagnosis.

[7]  B Buis,et al.  Continuous measurement of left ventricular volume in animals and humans by conductance catheter. , 1984, Circulation.

[8]  G L Freeman,et al.  Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals. , 2000, American journal of physiology. Heart and circulatory physiology.

[9]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[10]  T J Gawne,et al.  Estimating left ventricular offset volume using dual-frequency conductance catheters. , 1987, Journal of applied physiology.

[11]  C. H. Chen,et al.  Special Communication , 2004 .

[12]  Richard D. White,et al.  Estimation of current leakage in left and right ventricular conductance volumetry using a dynamic finite element model , 2000, IEEE Transactions on Biomedical Engineering.

[13]  D. Cheng Field and wave electromagnetics , 1983 .

[14]  Jan Baan,et al.  Computation of the Input Impedances of a Catheter for Cardiac Volumetry , 1984, IEEE Transactions on Biomedical Engineering.

[15]  Jonathan W. Valvano,et al.  3D finite element complex domain numerical models of electric fields in blood and myocardium , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[16]  H. P. Schwan,et al.  Electrical properties of blood and its constitutents: Alternating current spectroscopy , 1983, Blut: Zeitschrift für die Gesamte Blutforschung.

[17]  A. Redington,et al.  The effect of changing excitation frequency on parallel conductance in different sized hearts. , 1998, Cardiovascular research.

[18]  T. Skalak,et al.  Accuracy of the conductance catheter for measurement of ventricular volumes seen clinically: effects of electric field homogeneity and parallel conductance , 1997, IEEE Transactions on Biomedical Engineering.

[19]  J A Pearce,et al.  Development of a multifrequency conductance catheter-based system to determine LV function in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[20]  Sharon Thomsen,et al.  Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart. , 2006, American journal of physiology. Heart and circulatory physiology.

[21]  Jonathan W. Valvano,et al.  Nonlinear conductance-volume relationship for murine conductance catheter measurement system , 2005, IEEE Transactions on Biomedical Engineering.

[22]  Hong Cao,et al.  In-vivo measurement of swine myocardial resistivity , 2002, IEEE Transactions on Biomedical Engineering.

[23]  Chia-Ling Wei,et al.  Evidence of Time-Varying Myocardial Contribution by In Vivo Magnitude and Phase Measurement in Mice , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.