A complex‐difference phase‐contrast technique for measurement of volume flow rates

Magnetic resonance (MR) phase‐difference methods work well for measuring volumetric flow rates when the vessel diameter is large compared with the in‐plane voxel dimensions. For small vessels (eg, coronary arteries), partial‐volume effects introduce substantial errors in the measured volume flow rate. To correctly measure flow rates through a voxel, both the fraction of the voxel containing moving spins and the phase shift imparted to those spins must be known. The authors propose a flow measurement method that combines information obtained with both the complex‐difference and phase‐difference processing techniques and thereby provides the fractional volume occupied by the moving spins and the phase of those spins. The complex‐difference flow map method proposed results in improved accuracy of MR phase‐contrast flow measurements in the presence of partial‐volume effects.

[1]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[2]  T E Conturo,et al.  Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets , 1990, Magnetic resonance in medicine.

[3]  E. Hahn,et al.  Detection of sea‐water motion by nuclear precession , 1960 .

[4]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[5]  F. Korosec,et al.  Quantitative velocity images from thick slab 2D phase contrast , 1993, Magnetic resonance in medicine.

[6]  R L Ehman,et al.  Analysis of systematic and random error in MR volumetric flow measurements , 1993, Magnetic resonance in medicine.

[7]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[8]  E M Haacke,et al.  Optimizing blood vessel contrast in fast three‐dimensional MRI , 1990, Magnetic resonance in medicine.

[9]  D. Parker,et al.  Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effects , 1993, Journal of magnetic resonance imaging : JMRI.

[10]  N J Pelc,et al.  Arterial and venous blood flow: noninvasive quantitation with MR imaging. , 1992, Radiology.

[11]  T. Scalea,et al.  Blunt splenic injuries: nonsurgical treatment with CT, arteriography, and transcatheter arterial embolization of the splenic artery. , 1991, Radiology.

[12]  C. Dumoulin,et al.  Magnetic resonance angiography. , 1986, Radiology.

[13]  N J Pelc,et al.  Minimizing TE in moment‐nulled or flow‐encoded two‐and three‐dimensional gradient‐echo imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[14]  G H Glover,et al.  Vascular morphology by three-dimensional magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[15]  S K Holland,et al.  Nuclear magnetic resonance signal from flowing nuclei in rapid imaging using gradient echoes. , 1988, Medical physics.