Design of Interactively Time-Pulsed Microfluidic Mixers in Microchips using Numerical Simulation

In this paper, we propose a novel technique in which driving voltages are applied interactively to the respective inlet fluid flows of three configurations of a microfluidic device, namely T-shaped, double-T-shaped, and double-cross-shaped configurations, to induce electroosmotic flow (EOF) velocity variations in such a way as to develop a rapid mixing effect in the microchannel. In these configurations a microfluidic mixer apply only one electrokinetic driving force, which drives the sample fluids and simultaneously produces a periodic switching frequency. It requires no other external driving force to induce perturbations to the flow field. The effects of the main applied electric field, the interactive frequency, and the pullback electric field on the mixing performance are thoroughly examined numerically. The optimal interactive frequency range for a given set of micromixer parameters is identified for each type of control mode. The numerical results confirm that micromixers operating at an optimal interactive frequency are capable of delivering a significantly enhanced mixing performance. Furthermore, it is shown that the optimal interactive frequency depends upon the magnitude of the main applied electric field. The interactively pulsed mixers developed in this study have a strong potential for use in lab-on-a-chip systems. They involve a simpler fabrication process than either passive or active on-chip mixers and require less human intervention in operation than their bulky external counterparts.

[1]  Gwo-Bin Lee,et al.  Electrokinetically driven micro flow cytometers with integrated fiber optics for on-line cell/particle detection , 2004 .

[2]  R. Wightman,et al.  Probing electric fields inside microfluidic channels during electroosmotic flow with fast-scan cyclic voltammetry. , 2004, Analytical chemistry.

[3]  Chien-Hsiung Tsai,et al.  Experimental and numerical analysis of the geometry effects of low-dispersion turns in microfluidic systems , 2005 .

[4]  High‐resolution DNA separation in microcapillary electrophoresis chips utilizing double‐L injection techniques , 2004, Electrophoresis.

[5]  Jr-Lung Lin,et al.  Numerical simulation of electrokinetic focusing in microfluidic chips , 2002 .

[6]  Gwo-Bin Lee,et al.  Multiple injection techniques for microfluidic sample handling , 2003, Electrophoresis.

[7]  G. Guiochon,et al.  Timescales of transient processes in capillary electrophoresis , 1993 .

[8]  Robin H. Liu,et al.  Passive mixing in a three-dimensional serpentine microchannel , 2000, Journal of Microelectromechanical Systems.

[9]  Chang-Hsien Tai,et al.  Double-L injection technique for high performance capillary electrophoresis detection in microfluidic chips , 2004 .

[10]  Dongqing Li,et al.  Analysis of electrokinetic flow in microfluidic networks , 2004 .

[11]  Ya Jin,et al.  Numerical calculation of the electroosmotic flow at the cross region in microfluidic chips , 2003, Electrophoresis.

[12]  Ruey-Jen Yang,et al.  Computational analysis of electrokinetically driven flow mixing in microchannels with patterned blocks , 2004 .

[13]  D. Erickson,et al.  Influence of Surface Heterogeneity on Electrokinetically Driven Microfluidic Mixing , 2002 .

[14]  L. Fu,et al.  Numerical simulation of electrokinetic injection techniques in capillary electrophoresis microchips , 2005, Electrophoresis.

[15]  K. Mogensen,et al.  Recent developments in detection for microfluidic systems , 2004, Electrophoresis.

[16]  Che-Hsin Lin,et al.  A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions , 2005 .

[17]  Che-Hsin Lin,et al.  A novel microfluidic mixer utilizing electrokinetic driving forces under low switching frequency , 2005, Electrophoresis.

[18]  T. Johnson,et al.  Rapid microfluidic mixing. , 2002, Analytical chemistry.

[19]  E. Biddiss,et al.  Heterogeneous Surface Charge Enhanced Micromixing for Electrokinetic Flows , 2004 .

[20]  M. Ishida,et al.  Characteristics of High-Resolution Hemoglobin Measurement Microchip Integrated with Signal Processing Circuit , 2004 .

[21]  Che-Hsin Lin,et al.  Numerical analysis and experimental estimation of a low-leakage injection technique for capillary electrophoresis. , 2003, Analytical chemistry.

[22]  Nadine Aubry,et al.  Enhancement of microfluidic mixing using time pulsing. , 2003, Lab on a chip.

[23]  Jörg P Kutter,et al.  Pure‐silica optical waveguides, fiber couplers, and high‐aspect ratio submicrometer channels for electrokinetic separation devices , 2004, Electrophoresis.

[24]  B. Finlayson,et al.  Quantitative analysis of molecular interaction in a microfluidic channel: the T-sensor. , 1999, Analytical chemistry.

[25]  Juan G. Santiago,et al.  A review of micropumps , 2004 .

[26]  Alan G. R. Evans,et al.  Two simple micromixers based on silicon , 1998 .

[27]  Che-Hsin Lin,et al.  Microfluidic T-form mixer utilizing switching electroosmotic flow. , 2004, Analytical chemistry.

[28]  R. Kane,et al.  Microfluidic separation of DNA. , 2003, Current opinion in biotechnology.

[29]  Chien-Hsiung Tsai,et al.  Optimal configuration of capillary electrophoresis microchip with expansion chamber in separation channel. , 2006, Journal of chromatography. A.

[30]  F. Regnier,et al.  Stopped-flow enzyme assays on a chip using a microfabricated mixer. , 2003, Analytical chemistry.

[31]  Hengzi Wang,et al.  Numerical investigation of mixing in microchannels with patterned grooves , 2003 .

[32]  Gwo-Bin Lee,et al.  Enhancement of Electrokinetically-Driven Flow Mixing in Microchannel with Added Side Channels , 2005 .

[33]  L. Fu,et al.  Low‐voltage driven control in electrophoresis microchips by traveling electric field , 2003, Electrophoresis.

[34]  Yi-Kuen Lee,et al.  Efficient spatial-temporal chaotic mixing in microchannels , 2003 .

[35]  Daniel T Chiu,et al.  High‐power blue/UV light‐emitting diodes as excitation sources for sensitive detection , 2004, Electrophoresis.