Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: comparison of echo-planar, HASTE, and spin-echo sequences.

PURPOSE The purpose of this study was to evaluate the accuracy of T2 calculation from single shot imaging sequences such as echo-planar imaging (EPI) and half-Fourier single shot turbo spin-echo (HASTE) imaging. MATERIALS AND METHODS For the phantom study, we prepared vials containing different concentrations of agarose, copper sulfate, and nickel chloride. The temperature of the phantom was kept at 22 degrees C. MR images were obtained with a 1.5-Tesla superconductive magnet. Spin-echo (SE) -type EPI and HASTE sequences with different TEs were obtained for T2 calculation, and the T2 values were compared with those obtained from the Carr-Purcell-Meiborm-Gill (CPMG) sequence. The clinical study group consisted of 30 consecutive patients referred for MR imaging to characterize focal liver lesions. A total of 40 focal liver lesions were evaluated, including 25 primary or metastatic solid masses and 15 non-solid lesions. Single shot SE-type EPI and HASTE were both performed with TEs of 64 and 90 msec. RESULTS In the phantom study, the T2 values obtained from both single shot sequences showed significant correlations with those from the CPMG sequence (T2 on EPI vs. T2 on CPMG: r=0.98, p<0.01; T2 on HASTE vs. T2 on CPMG: r=0.99, p<0.01). In the clinical study, mean T2 values for liver calculated from EPI (42 msec) were significantly shorter than those calculated from the HASTE sequence (58 msec) (p<0.001). Mean T2 values for solid tumors were 95 msec with HASTE and 72 msec with EPI, and mean T2 values for non-solid lesions were 128 msec with HASTE and 159 msec with EPI. Although mean T2 values between solid and non-solid lesions were significantly different for both EPI and HASTE sequences (p=0.01 for HASTE, p<0.001 for EPI), the overlap of solid and non-solid lesions was less frequent in EPI than in HASTE. CONCLUSION With single shot sequences, it is possible to obtain the T2 values that show excellent correlation with the CPMG sequence. Although both HASTE and EPI are useful to calculate T2 values, EPI appears to be more accurate in characterizing focal liver lesions.

[1]  K. Ohtomo,et al.  Hepatic tumors: differentiation by transverse relaxation time (T2) of magnetic resonance imaging. , 1985, Radiology.

[2]  N L Kelekis,et al.  HASTE MR imaging: Description of technique and preliminary results in the abdomen , 1996, Journal of magnetic resonance imaging : JMRI.

[3]  K. Ohtomo,et al.  MR differentiation of hepatocellular carcinoma from cavernous hemangioma: complementary roles of FLASH and T2 values. , 1989, AJR. American journal of roentgenology.

[4]  F. Regan,et al.  MR urography using HASTE imaging in the assessment of ureteric obstruction. , 1996, AJR. American journal of roentgenology.

[5]  D. Mitchell,et al.  Motion artifact reduction in MR imaging of the abdomen: gradient moment nulling versus respiratory-sorted phase encoding. , 1988, Radiology.

[6]  M Takahashi,et al.  The value of MR urography that uses HASTE sequences to reveal urinary tract disorders. , 1996, AJR. American journal of roentgenology.

[7]  R. Edelman,et al.  Magnetic resonance imaging of cavernous hemangioma of the liver: tissue-specific characterization. , 1985, AJR. American journal of roentgenology.

[8]  M Takahashi,et al.  MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences. , 1996, AJR. American journal of roentgenology.

[9]  H. Hricak,et al.  Relative Intensity of Abdominal Organs in MR Images , 1985, Journal of computer assisted tomography.

[10]  T. Egglin,et al.  Differentiation between hemangiomas and metastases of the liver with ultrafast MR imaging: preliminary results with T2 calculations. , 1991, AJR. American journal of roentgenology.

[11]  M. Cohen,et al.  Value of T1 and T2 relaxation times from echoplanar MR imaging in the characterization of focal hepatic lesions. , 1993, AJR. American journal of roentgenology.