Effect of fiber orientation on the stress distribution within a leaflet of a polymer composite heart valve in the closed position.

Polymer trileaflet valves offer natural hemodynamics with the potential for better durability than commercially available tissue valves. Strength and durability of polymer-based valves may be increased through fiber reinforcement. A finite element analysis of the mechanics of a statically loaded polymer trileaflet aortic heart valve has been conducted. A parametric analysis was performed to determine the effects of fiber orientation and volume density in a single and double ply model. A maximum stress value of 1.02MPa was obtained in the non-reinforced model for a transvalvular load (downstream-upstream) of 120mmHg. The maximum stress on the downstream side of the leaflet was approximately twice the maximum stress on the upstream side, and always occurred on the interface with the valve stent. The single ply model reduced the stress on the polymer matrix, with the maximum reduction of at least 64% occurring when the fiber orientation was such that the fibers ran perpendicular to the stent edge. The double ply model further reduced the stress on the polymer matrix, with the maximum reduction of greater than 86% now occurring when the fibers are oriented most perpendicular to one another.

[1]  P. Schreurs,et al.  A three-dimensional mechanical analysis of a stentless fibre-reinforced aortic valve prosthesis. , 2000, Journal of biomechanics.

[2]  A A Sauren,et al.  Aortic valve histology and its relation with mechanics-preliminary report. , 1980, Journal of biomechanics.

[3]  Y. Missirlis,et al.  Aortic valve mechanics--Part I: material properties of natural porcine aortic valves. , 1978, Journal of bioengineering.

[4]  M. Thubrikar,et al.  Comparison of the in vivo and in vitro mechanical properties of aortic valve leaflets. , 1986, The Journal of thoracic and cardiovascular surgery.

[5]  M A Dokainish,et al.  Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents. , 1993, Journal of biomechanics.

[6]  Paul D. Stein,et al.  Comparison of finite element stress analysis of aortic valve leaflet using either membrane elements or solid elements , 1985 .

[7]  I. C. Howard,et al.  A three-dimensional analysis of a bioprosthetic heart valve. , 1991, Journal of biomechanics.

[8]  D. B. Smith,et al.  Effects of accelerated testing on porcine bioprosthetic heart valve fiber architecture. , 1998, Biomaterials.

[9]  J De Hart,et al.  A three-dimensional analysis of a fibre-reinforced aortic valve prosthesis. , 1998, Journal of biomechanics.

[10]  S. H. Kim,et al.  Stress distribution on the cusps of a polyurethane trileaflet heart valve prosthesis in the closed position. , 1991, Journal of biomechanics.

[11]  R Gutkowski,et al.  Optimal diameter of the stent for aortic valvular grafts. I. Studies on valve function and geometry. , 1976, The Journal of thoracic and cardiovascular surgery.

[12]  V. A. Kas'yanov,et al.  Structure and mechanical properties of the human aortic valve , 1985 .

[13]  R. E. Clark,et al.  Scanning and light microscopy of human aortic leaflets in stressed and relaxed states. , 1974, The Journal of thoracic and cardiovascular surgery.

[14]  D J Wheatley,et al.  Calcification and fatigue failure in a polyurethane heart value. , 1995, Biomaterials.

[15]  C J Burstone,et al.  Three-dimensional large displacement analysis of orthodontic appliances. , 1976, Journal of biomechanics.

[16]  G E Chetta,et al.  The design, fabrication and evaluation of a trileaflet prosthetic heart valve. , 1980, Journal of biomechanical engineering.

[17]  R E Clark,et al.  Stress analysis of aortic valve leaflets with smoothed geometrical data. , 1977, Journal of biomechanics.