Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers.

Compact analyzers suited to near-patient testing estimate hematocrit by measuring the conductivity of undiluted blood. We evaluated the accuracy of hematocrit determination of one such analyzer (Instrumentation Laboratory BGE analyzer) against an automated cell counter (EPC) and packed cell volume (PCV) microhematocrit. When specimens (n = 34) from outpatient and ward patients were analyzed with all three methods, the BGE analyzer correlated well with both EPC and PCV hematocrit determinations (BGE = 1.00 PCV + 0.3%, S(y)/x = 2.0%), suggesting that all three methods are similar in performance for most patients. However, a patient with increased plasma osmolality showed significant decreases in BGE and PCV hematocrits relative to the EPC method. The differences in hematocrit measurements could be reproduced by adding solutes to blood in vitro or by modifying the plasma osmolality of rats in vivo. Samples from patients undergoing cardiac surgery, whose blood had large changes in protein concentration, showed discrepancies between hematocrits by conductivity and other methods; similar effects could be produced by changes in protein concentration or in vitro addition of polyethylene glycol. We conclude that conductivity measurements provide accurate hematocrit results for physiologically normal subjects but not for some intensive-care and surgical patients.

[1]  R. Rosenthal,et al.  Measurement of the electric resistance of human blood; use in coagulation studies and cell volume determinations. , 1948, The Journal of laboratory and clinical medicine.

[2]  H. Fricke,et al.  A Mathematical Treatment of the Electric Conductivity and Capacity of Disperse Systems ii. The Capacity of a Suspension of Conducting Spheroids Surrounded by a Non-Conducting Membrane for a Current of Low Frequency , 1925 .

[3]  G. Bashein,et al.  Evaluation of a blood gas and chemistry monitor for use during surgery. , 1989, Anesthesiology.

[4]  T. Bills,et al.  Letter: Osmotic error in measurements of red-cell volume. , 1974, Lancet.

[5]  E. Cotlove Simple tail vein infusion method for renal clearance measurements in the rat. , 1961, Journal of applied physiology.

[6]  R. Carpenter,et al.  A Comparison of Conductivity‐Based Hematocrit Determinations With Conventional Laboratory Methods in Autologous Blood Transfusions , 1990, Anesthesia and analgesia.

[7]  B. Chernow,et al.  Bedside diagnostic blood testing. Its accuracy, rapidity, and utility in blood conservation. , 1991, JAMA.

[8]  S. Burrows Bedside blood gas and electrolyte monitoring in critically ill patients. , 1990, Critical care medicine.

[9]  F. Gotch,et al.  Comparison of conductivity measured hematocrit to microhematocrit. , 1991, ASAIO transactions.

[10]  M. Fleisher,et al.  Two whole-blood multi-analyte analyzers evaluated. , 1989, Clinical chemistry.

[11]  P. Flute,et al.  The examination of the blood. , 1960, The Practitioner.

[12]  J. Maxwell A Treatise on Electricity and Magnetism , 1873, Nature.