An adaptive beamforming method for ultrasound imaging based on the mean‐to‐standard‐deviation factor

HighlightsSignal mean‐to‐standard‐deviation factor (SMSF) is proposed as a weighting factor for ultrasound imaging.A robust SMSF is derived from the Fourier‐spectrum of aperture data.Square neighborhood average is applied to robust SMSF to enhance its performance.The proposed methods can reduce noise and reject clutter, thus achieve improvements in image resolution and contrast. ABSTRACT The beamforming performance has a large impact on image quality in ultrasound imaging. Previously, several adaptive weighting factors including coherence factor (CF) and generalized coherence factor (GCF) have been proposed to improved image resolution and contrast. In this paper, we propose a new adaptive weighting factor for ultrasound imaging, which is called signal mean‐to‐standard‐deviation factor (SMSF). SMSF is defined as the mean‐to‐standard‐deviation of the aperture data and is used to weight the output of delay‐and‐sum (DAS) beamformer before image formation. Moreover, we develop a robust SMSF (RSMSF) by extending the SMSF to the spatial frequency domain using an altered spectrum of the aperture data. In addition, a square neighborhood average is applied on the RSMSF to offer a more smoothed square neighborhood RSMSF (SN‐RSMSF) value. We compared our methods with DAS, CF, and GCF using simulated and experimental synthetic aperture data sets. The quantitative results show that SMSF results in an 82% lower full width at half‐maximum (FWHM) but a 12% lower contrast ratio (CR) compared with CF. Moreover, the SN‐RSMSF leads to 15% and 10% improvement, on average, in FWHM and CR compared with GCF while maintaining the speckle quality. This demonstrates that the proposed methods can effectively improve the image resolution and contrast.

[1]  Billy Y S Yiu,et al.  GPU-based minimum variance beamformer for synthetic aperture imaging of the eye. , 2015, Ultrasound in medicine & biology.

[2]  Jeremy Dahl,et al.  Short-lag spatial coherence weighted minimum variance beamformer for plane-wave images , 2016, 2016 IEEE International Ultrasonics Symposium (IUS).

[3]  Jørgen Arendt Jensen,et al.  Synthetic aperture ultrasound imaging. , 2006, Ultrasonics.

[4]  J. Ophir,et al.  Reduction of Image Noise in Elastography , 1993 .

[5]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Erwin J. Alles,et al.  Photoacoustic clutter reduction using short-lag spatial coherence weighted imaging , 2014, 2014 IEEE International Ultrasonics Symposium.

[7]  Douglas L. Jones,et al.  Overdetermined least-squares aberration estimates using common-midpoint signals , 2004, IEEE Transactions on Medical Imaging.

[8]  A. Mahloojifar,et al.  Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[10]  Giovanni Magenes,et al.  The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging , 2015, IEEE Transactions on Medical Imaging.

[11]  Tsuyoshi Murata,et al.  {m , 1934, ACML.

[12]  Dongwoon Hyun,et al.  In vivo demonstration of a real-time simultaneous B-mode/spatial coherence GPU-based beamformer , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[13]  G. Trahey,et al.  Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results. , 2013, Ultrasound in medicine & biology.

[14]  Piero Tortoli,et al.  High Frame-Rate, High Resolution Ultrasound Imaging With Multi-Line Transmission and Filtered-Delay Multiply And Sum Beamforming , 2017, IEEE Trans. Medical Imaging.

[15]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[16]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[17]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  J. Camacho,et al.  Phase Coherence Imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  B. Witek,et al.  Modular & scalable ultrasound platform with GPU processing , 2012, 2012 IEEE International Ultrasonics Symposium.

[20]  Gregg E Trahey,et al.  In vivo application of short-lag spatial coherence imaging in human liver. , 2013, Ultrasound in medicine & biology.

[21]  Hu Peng,et al.  Signal Eigenvalue Factor for Synthetic Transmit Aperture Ultrasound Imaging , 2018, IEEE Access.

[22]  Sverre Holm,et al.  Implementing capon beamforming on a GPU for real-time cardiac ultrasound imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[23]  Shun Zhang,et al.  Short-lag Spatial Coherence Ultrasound Imaging with Adaptive Synthetic Transmit Aperture Focusing , 2017, Ultrasonic imaging.

[24]  Ole Marius Hoel Rindal,et al.  The ultrasound toolbox , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[25]  Liang Zhou,et al.  Zero-Phase Filtered Delay Multiply and Sum in Ultrasound Computed Tomography , 2017 .

[26]  Eigil Samset,et al.  Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[27]  Purang Abolmaesumi,et al.  Accumulated Angle Factor-Based Beamforming to Improve the Visualization of Spinal Structures in Ultrasound Images , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[28]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging. , 2017, Ultrasound in medicine & biology.

[29]  Yong-Ping Zheng,et al.  Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging. , 2016, Ultrasonics.

[30]  Nick Bottenus,et al.  Acoustic reciprocity of spatial coherence in ultrasound imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[31]  Piero Tortoli,et al.  Architecture of an Ultrasound System for Continuous Real-Time High Frame Rate Imaging , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[32]  Piero Tortoli,et al.  Experimental evaluation of ultrasound higher‐order harmonic imaging with Filtered‐Delay Multiply And Sum (F‐DMAS) non‐linear beamforming , 2018, Ultrasonics.

[33]  B M Asl,et al.  Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Jinhua Yu,et al.  Coherence factor and Wiener postfilter in synthetic aperture ultrasound imaging. , 2017, The Journal of the Acoustical Society of America.

[35]  Dongwoon Hyun,et al.  Lesion Detectability in Diagnostic Ultrasound with Short-Lag Spatial Coherence Imaging , 2011, Ultrasonic imaging.

[36]  M. Lewandowski,et al.  GPU implementation of the STA algorithm on I/Q data , 2012, 2012 IEEE International Ultrasonics Symposium.

[37]  Gregg Trahey,et al.  In vivo performance evaluation of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[38]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[39]  Andreas Austeng,et al.  An Optimized GPU Implementation of the MVDR Beamformer for Active Sonar Imaging , 2015, IEEE Journal of Oceanic Engineering.

[40]  Dongwoon Hyun,et al.  Real-time high-framerate in vivo cardiac SLSC imaging with a GPU-based beamformer , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[41]  Yang Zhang,et al.  Ultrafast Ultrasound Imaging Using Combined Transmissions With Cross-Coherence-Based Reconstruction , 2018, IEEE Transactions on Medical Imaging.

[42]  Shi Zhang,et al.  An efficient subarray average delay multiply and sum beamformer algorithm in ultrasound imaging , 2018, Ultrasonics.

[43]  Xun Chen,et al.  Short-lag spatial coherence combined with eigenspace-based minimum variance beamformer for synthetic aperture ultrasound imaging , 2017, Comput. Biol. Medicine.

[44]  Sverre Holm,et al.  Wiener beamforming and the coherence factor in ultrasound imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[45]  Pai-Chi Li,et al.  Adaptive imaging using the generalized coherence factor. , 2003, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[46]  S. I. Nikolov,et al.  SARUS: A synthetic aperture real-time ultrasound system , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[47]  Bastien Denarie,et al.  The angular apodization in coherent plane-wave compounding [Correspondence] , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[48]  Vassilis Sboros,et al.  Experimental performance assessment of the sub‐band minimum variance beamformer for ultrasound imaging , 2017, Ultrasonics.

[49]  A. Austeng,et al.  Adaptive Beamforming Applied to Medical Ultrasound Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[50]  Lediju Bell,et al.  Improved Endocardial Border Definition with Short-Lag Spatial Coherence (SLSC) Imaging , 2012 .