Automated detection of choroid boundary and vessels in optical coherence tomography images

Structural changes in the choroid, a layer located between the retina and sclera, could indicate various vision impairments. Consequently, ophthalmologists inspect optical coherence tomography (OCT) scans of the posterior section of the eye towards making diagnosis. With a view to assist diagnosis, we propose an automated technique for segmentation of the choroid layer. Specifically, we detect the upper and lower boundaries of the choroid using structural similarity and adaptive Hessian analysis. Subsequently, we detect choroid vessels within those boundaries using a level set method. Experimental results are presented using spectral domain (SD) OCT images.

[1]  Sumohana S. Channappayya,et al.  An automated algorithm for blood vessel count and area measurement in 2-D choroidal scan images , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  Josh Wallman,et al.  The multifunctional choroid , 2010, Progress in Retinal and Eye Research.

[3]  Martin F. Kraus,et al.  Automated three-dimensional choroidal vessel segmentation of 3D 1060 nm OCT retinal data , 2012, Biomedical optics express.

[4]  J. Sethian,et al.  Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations , 1988 .

[5]  Chunming Li,et al.  Distance Regularized Level Set Evolution and Its Application to Image Segmentation , 2010, IEEE Transactions on Image Processing.

[6]  W. Marsden I and J , 2012 .

[7]  Alan L. Yuille,et al.  Region Competition: Unifying Snakes, Region Growing, and Bayes/MDL for Multiband Image Segmentation , 1996, IEEE Trans. Pattern Anal. Mach. Intell..

[8]  Xiaodong Wu,et al.  Semiautomated segmentation of the choroid in spectral-domain optical coherence tomography volume scans. , 2013, Investigative ophthalmology & visual science.

[9]  Alejandro F. Frangi,et al.  Muliscale Vessel Enhancement Filtering , 1998, MICCAI.

[10]  Guido Gerig,et al.  Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images , 1998, Medical Image Anal..

[11]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[12]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[13]  T. Ritesh Chandra,et al.  3D visualization and mapping of choroid thickness based on optical coherence tomography: A step-by-step geometric approach , 2013, 2013 International Conference on 3D Imaging.

[14]  E. Parzen On Estimation of a Probability Density Function and Mode , 1962 .

[15]  Lihteh Wu,et al.  Choroidal imaging by spectral domain-optical coherence tomography , 2013 .

[16]  M. Sonka,et al.  Automated segmentation of the choroid from clinical SD-OCT. , 2012, Investigative ophthalmology & visual science.

[17]  John W. Fisher,et al.  Submitted to Ieee Transactions on Image Processing a Nonparametric Statistical Method for Image Segmentation Using Information Theory and Curve Evolution , 2022 .

[18]  Alessandro Foi,et al.  Image Denoising by Sparse 3-D Transform-Domain Collaborative Filtering , 2007, IEEE Transactions on Image Processing.