Time resolved X-ray emission diagnostics in an axis-symmetric simple mirror trap

Time resolved characterization of plasma X-ray emission represents an innovative technique to characterize non-equilibrium phases in Electron Cyclotron Resonance Ion Sources (ECRIS). Indeed, although ECRIS plasmas are usually in dynamical equilibrium, many relevant phenomena are characterized by fast transients and require a dedicated diagnostics to be fully investigated. In particular, time resolved diagnostics can be applied to characterize the X ray emission during the plasma turn on and off and during the turbulence phenomena induced by Cyclotron-Maser instability. This paper presents the experimental set-up used during the last campaign at measurement carried out at the Istituto Nazionale Fisica Nucleare -Laboratori Nazionali del Sud (INFN-LNS), together with the main achieved results. Particular relevance will be given to the characterization of the afterglow phase, which highlighted the existence of two electron populations characterized by different mean lifetime. Evidences of X-ray bursts emission in the afterglow phase, compatible with Cyclotron Maser instability, will be also shown.

[1]  M. Giarrusso,et al.  Multidiagnostics setups for magnetoplasmas devoted to astrophysics and nuclear astrophysics research in compact traps , 2019, Journal of Instrumentation.

[2]  D. Mascali,et al.  Multidiagnostics investigation of the role of the magnetic field profile in a simple mirror trap , 2019, Physical Review Accelerators and Beams.

[3]  G. Torrisi,et al.  Characterization of ECR plasma by means of radial and axial X-ray diagnostics , 2019, Journal of Instrumentation.

[4]  Santo Gammino,et al.  The Flexible Plasma Trap (FPT) for the production of overdense plasmas , 2017, 2201.01570.

[5]  D. Mascali,et al.  PANDORA, a new facility for interdisciplinary in-plasma physics , 2017, 1703.00479.

[6]  D. Mansfeld,et al.  Cyclotron instability in the afterglow mode of minimum-B ECRIS. , 2016, The Review of scientific instruments.

[7]  J. Pálinkás,et al.  Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging. , 2016, The Review of scientific instruments.

[8]  Hannu Koivisto,et al.  Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating , 2015 .

[9]  D. Mansfeld,et al.  Microwave emission related to cyclotron instabilities in a minimum-B electron cyclotron resonance ion source plasma , 2015 .

[10]  D. Mansfeld,et al.  Beam current oscillations driven by cyclotron instabilities in a minimum-B electron cyclotron resonance ion source plasma , 2014 .

[11]  Tao Zhang,et al.  High current H2(+) and H3(+) beam generation by pulsed 2.45 GHz electron cyclotron resonance ion source. , 2014, The Review of scientific instruments.

[12]  J. Isac,et al.  Electronic temperatures, densities, and plasma x-ray emission of a 14.5 GHz electron-cyclotron resonance ion source. , 2010, The Review of scientific instruments.

[13]  S. Golubev,et al.  Cyclotron-resonance maser driven by magnetic compression of rarefied plasma. , 2007, Physical review letters.

[14]  R Geller,et al.  Electron Cyclotron Resonance Ion Sources and ECR Plasmas , 2018 .

[15]  K. Langbein EXPERIMENTAL INVESTIGATION OF THE AFTERGLOW OF THE PULSED ELECTRON CYCLOTRON RESONANCE DISCHARGE , 1996 .