Fire performance of metal-free timber connections

The fire performance of heavy timber frame structures is often limited by the poor fire performance of its connections. Conventional timber connections, dowelled or toothed plate connections typically use steel as a connector material. In a fire, the steel parts rapidly conduct heat into the timber, leading to reduced fire performance. Replacing metallic connectors with alternative non-metallic, low thermal conductivity connector materials can, therefore, lead to improved connection performance in fire. This paper presents an experimental study into the fire performance of metal-free timber connections comprising a hot-pressed plywood flitch plate and glass-fibre-reinforced polymer dowels. The thermal behaviour of the connections at elevated temperatures is studied using a standard cone calorimeter apparatus and a novel heat transfer rate inducing system. The latter is a fire testing system developed at the University of Edinburgh. The mechanical behaviour of the connection during severe heating was also ...

[1]  Birgit Östman,et al.  Fire safety in timber buildings - Technical guideline for Europe. , 2010 .

[2]  T Harmathy,et al.  Fire Test Standard in the Light of Fire Research , 1970 .

[3]  Massimo Fragiacomo,et al.  Fire performance of bolted connections in laminated veneer lumber , 2009 .

[4]  M. Fan,et al.  Fire resistance characterisation of hemp fibre reinforced polyester composites for use in the construction industry , 2014 .

[5]  Roza Aseeva,et al.  Fire Behavior and Fire Protection in Timber Buildings , 2013, Springer Series in Wood Science.

[6]  L. Damkilde,et al.  Dowel Type Timber Connections Strength modelling , 2001 .

[7]  P. Walker,et al.  Modelling of Non-metallic Timber Connections at Elevated Temperatures , 2014 .

[8]  G. M. Newman Structural design for fire , 1991 .

[9]  Birgit Östman,et al.  Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 1 - Literature Review , 2016 .

[10]  Andrea Frangi Brandverhalten von Holz-Beton-Verbunddecken , 2001 .

[11]  Robert J. Ross,et al.  Wood handbook : wood as an engineering material , 2010 .

[12]  Frank Lam,et al.  Reversed-cyclic behavior of a novel heavy timber tube connection , 2006 .

[13]  Peter Walker,et al.  Experimental performance of non-metallic mechanically fastened timber connections , 2010 .

[14]  C. Arya Eurocode 5: Design of timber structures , 2009 .

[15]  Guillermo Rein,et al.  Structural Engineering and Fire Dynamics: Advances at the Interface , 2011 .

[16]  Luke Bisby,et al.  A contemporary review of large-scale non-standard structural fire testing , 2013 .

[17]  George Hadjisophocleous,et al.  Fire resistance performance of unprotected wood–wood–wood and wood–steel–wood connections: A literature review and new data correlations , 2010 .

[18]  Guillermo Rein,et al.  Structural Engineering and Fire Dynamics: Advances at the Interface and Buchanan's Challenge , 2011 .

[19]  Lazaros Tsantaridis,et al.  Correlation between cone calorimeter data and time to flashover in the room fire test , 1994 .

[20]  Andrew H. Buchanan,et al.  Structural Design for Fire Safety , 2001 .

[21]  L. Bank Composites for Construction: Structural Design with FRP Materials , 2006 .

[22]  Andrea Frangi,et al.  Experimental fire analysis of steel‐to‐timber connections using dowels and nails , 2009 .

[23]  Luke Bisby,et al.  Experimental review of the homogeneous temperature assumption in post-flashover compartment fires , 2010 .

[24]  J. Torero,et al.  A Heat-Transfer Rate Inducing System (H-TRIS) Test Method , 2016, Fire Safety Journal.

[25]  C. Maluk,et al.  Development and application of a novel test method for studying the fire behaviour of CFRP prestressed concrete structural elements , 2014 .

[26]  Andrea Frangi,et al.  FIRE RESISTANCE TESTS ON BEAM-TO-COLUMN SHEAR CONNECTIONS , 2014 .