Effect of Experimental Design on the Prediction Performance of Calibration Models Based on Near-Infrared Spectroscopy for Pharmaceutical Applications

Near-infrared spectroscopy (NIRS) is a valuable tool in the pharmaceutical industry, presenting opportunities for online analyses to achieve real-time assessment of intermediates and finished dosage forms. The purpose of this work was to investigate the effect of experimental designs on prediction performance of quantitative models based on NIRS using a five-component formulation as a model system. The following experimental designs were evaluated: five-level, full factorial (5-L FF); three-level, full factorial (3-L FF); central composite; I-optimal; and D-optimal. The factors for all designs were acetaminophen content and the ratio of microcrystalline cellulose to lactose monohydrate. Other constituents included croscarmellose sodium and magnesium stearate (content remained constant). Partial least squares-based models were generated using data from individual experimental designs that related acetaminophen content to spectral data. The effect of each experimental design was evaluated by determining the statistical significance of the difference in bias and standard error of the prediction for that model's prediction performance. The calibration model derived from the I-optimal design had similar prediction performance as did the model derived from the 5-L FF design, despite containing 16 fewer design points. It also outperformed all other models estimated from designs with similar or fewer numbers of samples. This suggested that experimental-design selection for calibration-model development is critical, and optimum performance can be achieved with efficient experimental designs (i.e., optimal designs).

[1]  E. Pitman A NOTE ON NORMAL CORRELATION , 1939 .

[2]  G. Box,et al.  A Basis for the Selection of a Response Surface Design , 1959 .

[3]  G. Box,et al.  THE CHOICE OF A SECOND ORDER ROTATABLE DESIGN , 1963 .

[4]  J. Koenig,et al.  Least-Squares Curve-Fitting of Fourier Transform Infrared Spectra with Applications to Polymer Systems , 1977 .

[5]  David M. Haaland,et al.  Improved Sensitivity of Infrared Spectroscopy by the Application of Least Squares Methods , 1980 .

[6]  Chris W. Brown,et al.  Matrix representations and criteria for selecting analytical wavelengths for multicomponent spectroscopic analysis , 1982 .

[7]  Chris W. Brown,et al.  Nonlinear multicomponent analysis by infrared spectrophotometry , 1983 .

[8]  I. Jolliffe Principal Components in Regression Analysis , 1986 .

[9]  Tormod Næs,et al.  Selection of Samples for Calibration in Near-Infrared Spectroscopy. Part I: General Principles Illustrated by Example , 1989 .

[10]  Tormod Næs,et al.  Selection of Samples for Calibration in Near-Infrared Spectroscopy. Part II: Selection Based on Spectral Measurements , 1990 .

[11]  S. D. Jong SIMPLS: an alternative approach to partial least squares regression , 1993 .

[12]  Tom Fearn,et al.  Comparing Standard Deviations , 1996 .

[13]  P. L. DaviesFebruary THE ONE-WAY ANALYSIS OF VARIANCE , 1997 .

[14]  Mats Josefson,et al.  Quantification of an Active Substance in a Tablet by NIR and Raman Spectroscopy , 1998 .

[15]  Tormod Næs,et al.  A user-friendly guide to multivariate calibration and classification , 2002 .

[16]  A. ADoefaa,et al.  ? ? ? ? f ? ? ? ? ? , 2003 .

[17]  H. Mark Application of an improved procedure for testing the linearity of analytical methods to pharmaceutical analysis. , 2003, Journal of pharmaceutical and biomedical analysis.

[18]  Christopher D. Brown,et al.  Discordance between net analyte signal theory and practical multivariate calibration. , 2004, Analytical chemistry.

[19]  R. Reed,et al.  In-line monitoring of moisture content in fluid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy. , 2005, Analytical chemistry.

[20]  James K Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part I: D-optimal design for characterization of powder mixing and preliminary spectral data evaluation. , 2006, Journal of pharmaceutical sciences.

[21]  James K Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending: Part II: Qualitative near-infrared models for prediction of blend homogeneity. , 2006, Journal of pharmaceutical sciences.

[22]  Anthony Walmsley,et al.  Response-Surface Modeling and Experimental Design , 2006 .

[23]  James K. Drennen,et al.  The Financial Returns on Investments in Process Analytical Technology and Lean Manufacturing: Benchmarks and Case Study , 2007, Journal of Pharmaceutical Innovation.

[24]  James K. Drennen,et al.  Process analytical technology case study, part III: Calibration monitoring and transfer , 2005, AAPS PharmSciTech.

[25]  Zhenqi Shi,et al.  Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond. , 2008, Journal of pharmaceutical and biomedical analysis.

[26]  M. Blanco,et al.  API Determination by NIR Spectroscopy Across Pharmaceutical Production Process , 2008, AAPS PharmSciTech.

[27]  James K. Drennen,et al.  Process analytical technology case study part I: Feasibility studies for quantitative near-infrared method development , 2005, AAPS PharmSciTech.

[28]  C. Anderson,et al.  Figures of Merit Comparison of Reflectance and Transmittance Near-Infrared Methods for the Prediction of Constituent Concentrations in Pharmaceutical Compacts , 2008, Journal of Pharmaceutical Innovation.

[29]  J. Drennen,et al.  Process analytical technology case study: Part II. Development and validation of quantitative near-infrared calibrations in support of a process analytical technology application for real-time release , 2005, AAPS PharmSciTech.

[30]  D. Oelkrug,et al.  Using scattering and absorption spectra as MCR-hard model constraints for diffuse reflectance measurements of tablets. , 2009, Analytica chimica acta.

[31]  A near-infrared spectroscopic investigation of relative density and crushing strength in four-component compacts. , 2009, Journal of pharmaceutical sciences.

[32]  Robust calibration design in the pharmaceutical quantitative measurements with near-infrared (NIR) spectroscopy: Avoiding the chemometric pitfalls. , 2009, Journal of pharmaceutical sciences.

[33]  Manel Bautista,et al.  On-line monitoring of a granulation process by NIR spectroscopy. , 2010, Journal of pharmaceutical sciences.

[34]  R. Boddy,et al.  Central Composite Designs , 2010 .

[35]  M. Blanco,et al.  Influence of physical factors on the accuracy of calibration models for NIR spectroscopy. , 2010, Journal of pharmaceutical and biomedical analysis.

[36]  C. Huck,et al.  Near-infrared reflection spectroscopy (NIRS) as a successful tool for simultaneous identification and particle size determination of amoxicillin trihydrate. , 2011, Journal of pharmaceutical and biomedical analysis.

[37]  Douglas C. Montgomery,et al.  An Expository Paper on Optimal Design , 2011 .

[38]  Xinwei Deng,et al.  Experimental design , 2012, WIREs Data Mining Knowl. Discov..

[39]  Pharmaceutical Applications of Near-Infrared Spectroscopy , 2012 .

[40]  L. Kux OF HEALTH AND HUMAN SERVICES Food and Drug Administration , 2014 .