Microbial UV fluence-response assessment using a novel UV-LED collimated beam system.

A research study has been performed to determine the ultraviolet (UV) fluence-response of several target non-pathogenic microorganisms to UV light emitting diodes (UV-LEDs) by performing collimated beam tests. UV-LEDs do not contain toxic mercury, offer design flexibility due to their small size, and have a longer operational life than mercury lamps. Comsol Multiphysics was utilized to create an optimal UV-LED collimated beam design based on number and spacing of UV-LEDs and distance of the sample from the light source while minimizing the overall cost. The optimized UV-LED collimated beam apparatus and a low-pressure mercury lamp collimated beam apparatus were used to determine the UV fluence-response of three surrogate microorganisms (Escherichia coli, MS-2, T7) to 255 nm UV-LEDs, 275 nm UV-LEDs, and 254 nm low-pressure mercury lamps. Irradiation by low-pressure mercury lamps produced greater E. coli and MS-2 inactivation than 255 nm and 275 nm UV-LEDs and similar T7 inactivation to irradiation by 275 nm UV-LEDs. The 275 nm UV-LEDs produced more efficient T7 and E. coli inactivation than 255 nm UV-LEDs while both 255 nm and 275 nm UV-LEDs produced comparable microbial inactivation for MS-2. Differences may have been caused by a departure from the time-dose reciprocity law due to microbial repair mechanisms.

[1]  J. Bolton Calculation of ultraviolet fluence rate distributions in an annular reactor: significance of refraction and reflection , 2000 .

[2]  Regina Sommer,et al.  Spectral sensitivity of Bacillus subtilis spores and MS2 coliphage for validation testing of ultraviolet reactors for water disinfection. , 2005, Environmental science & technology.

[3]  Andrew A. Allerman,et al.  Final LDRD report :ultraviolet water purification systems for rural environments and mobile applications. , 2005 .

[4]  K. Linden,et al.  Comparative disinfection efficiency of pulsed and continuous-wave UV irradiation technologies. , 2008, Water research.

[5]  R. Rahn Potassium Iodide as a Chemical Actinometer for 254 nm Radiation: Use of lodate as an Electron Scavenger , 1997 .

[6]  J G Anderson,et al.  Pulsed ultra-violet inactivation spectrum of Escherichia coli. , 2005, Water research.

[7]  Mika Sillanpää,et al.  Ultraviolet light-emitting diodes in water disinfection , 2009, Environmental science and pollution research international.

[8]  K. Linden,et al.  Comparative Inactivation of Bacillus Subtilis Spores and MS-2 Coliphage in a UV Reactor: Implications for Validation , 2006 .

[9]  Karl G. Linden,et al.  Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments , 2003 .

[10]  W. Harm Biological effects of ultraviolet radiation , 1980 .

[11]  Michael S. Shur,et al.  III-nitride based deep ultraviolet light sources , 2008, SPIE OPTO.

[12]  K. Linden,et al.  Comparative effectiveness of UV wavelengths for the inactivation of Cryptosporidium parvum oocysts in water. , 2001, Water science and technology : a journal of the International Association on Water Pollution Research.

[13]  J. Bolton,et al.  Quantum Yield of the Iodide–Iodate Chemical Actinometer: Dependence on Wavelength and Concentration¶ , 2003, Photochemistry and photobiology.

[14]  A. Bérces,et al.  Phages T7 in biological UV dose measurements , 1992 .

[15]  B. F. Kalisvaart Re-use of wastewater: preventing the recovery of pathogens by using medium-pressure UV lamp technology. , 2004, Water science and technology : a journal of the International Association on Water Pollution Research.

[16]  A. Cabaj,et al.  Time dose reciprocity in UV disinfection of water , 1998 .

[17]  Harold Wright,et al.  Development and characterization of nonpathogenic surrogates for UV reactor validation , 2007 .

[18]  Masatake Akutagawa,et al.  Development of a new water sterilization device with a 365 nm UV-LED , 2007, Medical & Biological Engineering & Computing.