EFFECTS OF DENTAL IMPLANT LENGTH AND BONE QUALITY ON BIOMECHANICAL RESPONSES IN BONE AROUND IMPLANTS: A 3-D NON-LINEAR FINITE ELEMENT ANALYSIS

The aim of this study was to evaluate the influence of implant length and bone quality on the biomechanical aspects in alveolar bone and dental implant using non-linear finite element analysis. Two fixture lengths (8 and 13mm) of Frialit-2 root-form titanium implants were buried in 4 types of bone modeled by varying the elastic modulus for cancellous bone. Contact elements were used to simulate the realistic interface fixation within the implant system. Axial and lateral (buccolingual) loadings were applied at the top of the abutment to simulate the occlusal forces. The simulated results indicated that the maximum strain values of cortical and cancellous bone increased with lower bone density. In addition, the variations of cortical bony strains between 13mm and 8mm long implants were not significantly as a results of the same contact areas between implant fixture and cortical bone were found for different implant lengths. Lateral occlusal forces significantly increased the bone strain values when compared with axial occlusal forces regardless of the implant lengths and bone qualities. Loading conditions were found as the most important factor than bone qualities and implant lengths affecting the biomechanical aspects for alveolar bone and implant systems. The simulated results implied that further understanding of the role of occlusal adjustment influencing the loading directions are needed and might affect the long-term success of an implant system.

[1]  M. Çehreli,et al.  The influence of functional forces on the biomechanics of implant-supported prostheses--a review. , 2002, Journal of dentistry.

[2]  F. Bosman,et al.  A comparison of three finite element models of an edentulous mandible provided with implants. , 1993, Journal of oral rehabilitation.

[3]  A Versluis,et al.  Why do Shear Bond Tests Pull Out Dentin? , 1997, Journal of dental research.

[4]  T Jemt,et al.  A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. , 1996, Clinical oral implants research.

[5]  Y Akagawa,et al.  A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. , 1998, Journal of oral rehabilitation.

[6]  T. Albrektsson,et al.  Biological aspects of implant dentistry: osseointegration. , 1994, Periodontology 2000.

[7]  R. B. Ashman,et al.  Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. , 1993, Journal of biomechanics.

[8]  G E Carlsson,et al.  Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. , 1988, The Journal of prosthetic dentistry.

[9]  C H Chang,et al.  Automatic finite element mesh generation for maxillary second premolar. , 1999, Computer methods and programs in biomedicine.

[10]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[11]  J. Kent,et al.  Hydroxyapatite-coated cylindrical implants in the posterior mandible: 10-year observations. , 1996, The International journal of oral & maxillofacial implants.

[12]  G L Kinzel,et al.  A finite element survey of eleven endosseous implants. , 1990, The Journal of prosthetic dentistry.

[13]  Chun-Li Lin,et al.  Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces. , 2003, The International journal of oral & maxillofacial implants.

[14]  C. L. Lin,et al.  Multifactorial analysis of an MOD restored human premolar using auto-mesh finite element approach. , 2001, Journal of oral rehabilitation.

[15]  U. Lekholm,et al.  Patient selection and preparation , 1985 .

[16]  H. Iplikçioğlu,et al.  Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant. , 2003, The International journal of oral & maxillofacial implants.

[17]  F. Isidor,et al.  Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. , 1996, Clinical oral implants research.

[18]  George A. Zarb,et al.  Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .

[19]  M. C. Lee,et al.  Effects of posts on dentin stress distribution in pulpless teeth. , 1992, The Journal of prosthetic dentistry.

[20]  U. Belser,et al.  Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. , 2000, The International journal of oral & maxillofacial implants.

[21]  Holmes Dc,et al.  Influence of bone quality on stress distribution for endosseous implants. , 1997, The Journal of oral implantology.