Three-dimensional volumetric human meibomian gland investigation using polarization-sensitive optical coherence tomography

Abstract. In this study, polarization-sensitive optical coherence tomography (PS-OCT) capable of providing polarization contrasts such as phase retardation and degree of polarization uniformity (DOPU) was used for visualizing human meibomian glands (MGs) and investigating morphological characteristics of them. Especially, with the help of the DOPU contrast, MGs were exclusively extracted from the volumetric OCT image. In vivo PS-OCT measurements were performed on the upper eyelids of different age groups. From these measurements, different age-dependent aspects of the MG structure were also observed. Based on these observations, it can be inferred that the PS-OCT system has the potential for clinical diagnosis and investigation of MG-related dry eye diseases like MG dysfunction (MGD) and acinar atrophy.

[1]  U. Schmidt-Erfurth,et al.  Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography. , 2008, Optics express.

[2]  Yoshiaki Yasuno,et al.  Birefringence measurement of cornea and anterior segment by office-based polarization-sensitive optical coherence tomography , 2011, Biomedical optics express.

[3]  Kostadinka Bizheva,et al.  In vivo volumetric imaging of the human upper eyelid with ultrahigh-resolution optical coherence tomography. , 2010, Journal of biomedical optics.

[4]  R E Smith,et al.  Meibomian gland studies: comparison of steer and human lipids. , 1981, Investigative ophthalmology & visual science.

[5]  Barry Cense,et al.  Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components. , 2004, Optics letters.

[6]  Lyndon Jones,et al.  Historical overview of imaging the meibomian glands , 2013 .

[7]  Kazuhiro Kurokawa,et al.  Advanced multi-contrast Jones matrix optical coherence tomography for Doppler and polarization sensitive imaging. , 2013, Optics express.

[8]  T. Yatagai,et al.  Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method. , 2006, Optics express.

[9]  Y. Yasuno,et al.  Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation. , 2008, Optics express.

[10]  A J Bron,et al.  Functional aspects of the tear film lipid layer. , 2004, Experimental eye research.

[11]  D R Korb,et al.  Volume of the human and rabbit meibomian gland system. , 1998, Advances in experimental medicine and biology.

[12]  Tae Joong Eom,et al.  In Vivo 3D Meibography of the Human Eyelid Using Real Time Imaging Fourier-Domain OCT , 2013, PloS one.