In situ corrosion monitoring of PC structures with distributed hybrid carbon fiber reinforced polymer sensors

Firstly, the fabrication and sensing properties of hybrid carbon fiber reinforced polymer (HCFRP) composite sensors are addressed. In order to provide a distributed sensing manner, the HCFRP sensors were divided into multi-zones with electrodes, and each zone was regarded as a separate sensor. Secondly, their application is studied to monitor the steel corrosion of prestressed concrete (PC) beams. The HCFRP sensors with different gauge lengths were mounted on a PC tendon, steel bar and embedded in tensile and compressive sides of the PC beam. The experiment was carried out under an electric accelerated corrosion and a constant load of about 54 kN. The results reveal that the corrosion of the PC tendon can be monitored through measuring the electrical resistance (ER) change of the HCFRP sensors. For the sensors embedded in tensile side of the PC beam, their ER increases as the corrosion progresses, whereas for the sensors embedded in compressive side, their ER decreases with corrosion time. Moreover, the strains due to the corrosion can be obtained based on the ER change and calibration curves of HCFRP sensors. The strains measured with traditional strain gauges agree with the strains calculated from the ER changes of HCFRP sensors. The electrical behavior of the zones where the corrosion was performed is much different from those of the other zones. In these zones, either there exist jumps in ER, or the ER increases with a much larger rate than those of the other zones. Distributed corrosion monitoring for PC structures is thus demonstrated with the application of HCFRP sensors through a proper installation of multi-electrodes.

[1]  Zhishen Wu,et al.  Self-diagnosis of structures strengthened with hybrid carbon-fiber-reinforced polymer sheets , 2005 .

[2]  Karl Schulte,et al.  Non-destructive testing of FRP by d.c. and a.c. electrical methods , 2001 .

[3]  Joung-Man Park,et al.  Cure monitoring and residual stress sensing of single-carbon fiber reinforced epoxy composites using electrical resistivity measurement , 2005 .

[4]  Hiroaki Yanagida,et al.  Self-Diagnosing Performance for Fracture in CFGFRP-Reinforced Concrete , 1993 .

[5]  G. Giraud,et al.  In-situ monitoring of damage in CFRP laminates by means of AC and DC measurements , 2001 .

[6]  S. Yoda,et al.  Changes in mechanical properties of graphites parallel and perpendicular to compressive prestress , 1990 .

[7]  Keiji Ogi,et al.  Characterization of piezoresistance behavior in a CFRP unidirectional laminate , 2005 .

[8]  Nobuo Takeda,et al.  Electromechanical modeling of unidirectional CFRP composites under tensile loading condition , 2002 .

[9]  Caiqian Yang,et al.  Distributed sensing of RC beams with HCFRP sensors , 2005, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[10]  C. Hansson Comments on electrochemical measurements of the rate of corrosion of steel in concrete , 1984 .

[11]  F. P. Ijsseling Application of electrochemical methods of corrosion rate determination to systems involving corrosion product layers: Part 1: Linear polarization resistance measurement as an example of a simple method that can be performed with commercially available instruments , 1986 .

[12]  D.D.L. Chung,et al.  TECHNICAL NOTE: A piezoresistive carbon filament polymer-matrix composite strain sensor , 1996 .

[13]  Zhishen Wu,et al.  Self-Diagnosis of Hybrid CFRP Rods and As-Strengthened Concrete Structures , 2006 .

[14]  Zhishen Wu,et al.  Electrical and Mechanical Characterization of Hybrid CFRP Sheets , 2006 .

[15]  L. Vincent,et al.  Damage mechanisms characterisation of carbon fibre/epoxy composite laminates by both electrical resistance measurements and acoustic emission analysis , 1996 .

[16]  C. Owston,et al.  Electrical properties of single carbon fibres , 1970 .

[17]  Zhishen Wu,et al.  Self-structural Health Monitoring Function of RC Structures with HCFRP Sensors , 2006 .

[18]  Jose Gonzalez,et al.  Methods for studying corrosion in reinforced concrete , 1994 .