A front-end ASIC with receive sub-array beamforming integrated with a 32 × 32 PZT matrix transducer for 3-D transesophageal echocardiography

This paper presents a power- and area-efficient front-end ASIC that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable the next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm2 ASIC, implemented in a low-voltage 0.18 μm CMOS process, effectively reduces the number of cables required in the probe's narrow shaft by means of 96 sub-array beamformers, which have a compact element-matched layout and employ mismatch-scrambling to enhance the dynamic range. The ASIC consumes less than 230 mW while receiving and its functionality has been successfully demonstrated in a 3-D imaging experiment.

[1]  Youngcheol Chae,et al.  Low Voltage, Low Power, Inverter-Based Switched-Capacitor Delta-Sigma Modulator , 2009, IEEE Journal of Solid-State Circuits.

[2]  Chao Chen,et al.  A compact 0.135-mW/channel LNA array for piezoelectric ultrasound transducers , 2015, ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC).

[3]  Ivan S Salgo,et al.  Three-dimensional echocardiographic technology. , 2007, Cardiology clinics.

[4]  Hae-Seung Lee,et al.  Ultrasonic Imaging Transceiver Design for CMUT: A Three-Level 30-Vpp Pulse-Shaping Pulser With Improved Efficiency and a Noise-Optimized Receiver , 2013, IEEE Journal of Solid-State Circuits.

[5]  Morten Fischer Rasmussen,et al.  Row-column addressed 2-D CMUT arrays with integrated apodization , 2014, 2014 IEEE International Ultrasonics Symposium.

[6]  Michiel A. P. Pertijs,et al.  A mixed-signal multiplexing system for cable-count reduction in ultrasound probes , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[7]  Amin Nikoozadeh,et al.  Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[8]  Nico de Jong,et al.  A Front-End ASIC With Receive Sub-array Beamforming Integrated With a $32 \times 32$ PZT Matrix Transducer for 3-D Transesophageal Echocardiography , 2017, IEEE Journal of Solid-State Circuits.

[9]  Nico de Jong,et al.  A new transesophageal probe for newborns. , 2009, Ultrasound in medicine & biology.

[10]  N. de Jong,et al.  Design of a miniature ultrasound probe for 3D transesophageal echocardiography , 2014, 2014 IEEE International Ultrasonics Symposium.

[11]  Nico de Jong,et al.  Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Christian Prins,et al.  Low-power receive electronics for a miniature real-time 3D ultrasound probe , 2015, 2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI).

[13]  R. Cobbold Foundations of Biomedical Ultrasound , 2006 .

[14]  Frank M. L. van der Goes,et al.  A 66 dB SNDR pipelined split-ADC using class-AB residue amplifier with analog gain correction , 2015, ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC).

[15]  Jae-Yoon Sim,et al.  A single-chip time-interleaved 32-channel analog beamformer for ultrasound medical imaging , 2012, 2012 IEEE Asian Solid State Circuits Conference (A-SSCC).

[16]  N de Jong,et al.  Design of a micro-beamformer for a 2D piezoelectric ultrasound transducer , 2009, 2009 IEEE International Ultrasonics Symposium.

[17]  Byungsub Kim,et al.  24.8 An analog-digital-hybrid single-chip RX beamformer with non-uniform sampling for 2D-CMUT ultrasound imaging to achieve wide dynamic range of delay and small chip area , 2014, 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC).

[18]  Jaime Ramirez-Angulo,et al.  Power-efficient class AB CMOS buffer , 2009 .

[19]  B. Savord,et al.  Fully sampled matrix transducer for real time 3D ultrasonic imaging , 2003, IEEE Symposium on Ultrasonics, 2003.

[20]  Nico de Jong,et al.  A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[21]  Hae-Seung Lee,et al.  A Column-Row-Parallel ASIC Architecture for 3-D Portable Medical Ultrasonic Imaging , 2016, IEEE Journal of Solid-State Circuits.

[22]  I. Wygant A comparison of CMUTs and piezoelectric transducer elements for 2D medical imaging based on conventional simulation models , 2011, 2011 IEEE International Ultrasonics Symposium.

[23]  Andrea Mazzanti,et al.  A CMUT transceiver front-end with 100-V TX driver and 1-mW low-noise capacitive feedback RX amplifier in BCD-SOI technology , 2014, ESSCIRC 2014 - 40th European Solid State Circuits Conference (ESSCIRC).

[24]  O. Oralkan,et al.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Taeik Kim,et al.  A 0.004mm2 250μW ΔΣ TDC with time-difference accumulator and a 0.012mm2 2.5mW bang-bang digital PLL using PRNG for low-power SoC applications , 2012, 2012 IEEE International Solid-State Circuits Conference.

[26]  R. Phillips Guidance for Industry and FDA Staff Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers , 2008 .

[27]  송인성 A Ultrasound Probe , 2014 .

[28]  Amin Nikoozadeh,et al.  3D volumetric ultrasound imaging with a 32×32 CMUT array integrated with front-end ICs using flip-chip bonding technology , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[29]  Maysam Ghovanloo,et al.  Direct Digital Demultiplexing of Analog TDM Signals for Cable Reduction in Ultrasound Imaging Catheters , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[30]  Luca Lo Coco,et al.  Wide-band variable-gain LNA in 65 nm CMOS with inverter based amplifier for multi-tuners cable TV reception , 2009, 2009 Proceedings of ESSCIRC.