Identification of appropriate source models for accurate diffusion modeling of radiative transfer in a non-absorbing foam layer

The diffusion approximation is used to model the propagation of radiation scattered from a pulsed laser beam incident on a non-absorbing foam layer. Various mathematical models for the source term are considered, and integral transforms are used to solve the differential equation. Comparison of the calculated reflectance profiles with the results of Monte Carlo simulations indicates that careful selection of the source model leads to improved results. Diffusion theory source models which provide accurate predictions for radiative transfer and the limits on their accuracy are identified.

[1]  R. Aronson,et al.  Photon diffusion coefficient in an absorbing medium. , 1999, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  R. Alcouffe,et al.  Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues. , 1998, Physics in medicine and biology.

[3]  Ashleyj . Welch,et al.  Optical-Thermal Response of Laser-Irradiated Tissue , 1995 .

[4]  G. C. Pomraning,et al.  Linear Transport Theory , 1967 .

[5]  Frank K. Tittel,et al.  The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissues , 1995, Physics in medicine and biology.

[6]  B. Wilson,et al.  Monte Carlo modeling of light propagation in highly scattering tissues. I. Model predictions and comparison with diffusion theory , 1989, IEEE Transactions on Biomedical Engineering.

[7]  Lihong V. Wang,et al.  Monte Carlo Modeling of Light Transport in Tissues , 1995 .

[8]  J. Duderstadt,et al.  Nuclear reactor analysis , 1976 .

[9]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[10]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[11]  M. N. Özişik Boundary value problems of heat conduction , 1989 .

[12]  L. O. Svaasand,et al.  Boundary conditions for the diffusion equation in radiative transfer. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[13]  Yamada,et al.  Diffusion approximation for a dissipative random medium and the applications. , 1994, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[14]  S R Arridge,et al.  The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysis. , 1992, Physics in medicine and biology.

[15]  Sunil Kumar,et al.  Transient Radiation Transport in Participating Media Within a Rectangular Enclosure , 1997 .

[16]  L. O. Svaasand,et al.  Collimated light sources in the diffusion approximation. , 2000, Applied optics.

[17]  J. W. Chamberlain,et al.  Light Scattering in Planetary Atmospheres , 1976 .

[18]  Alfred L. Crosbie,et al.  Dirac-delta function approximations to the scattering phase function , 1985 .

[19]  J. Joseph,et al.  The delta-Eddington approximation for radiative flux transfer , 1976 .

[20]  John C. Chai,et al.  ONE-DIMENSIONAL TRANSIENT RADIATION HEAT TRANSFER MODELING USING A FINITE-VOLUME METHOD , 2003 .

[21]  M. Sakami,et al.  Analysis of light pulse transport through two-dimensional scattering and absorbing media , 2002 .

[22]  W. Egan,et al.  Optical properties of inhomogeneous materials: applications to geology , 1979 .