Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique.

STATEMENT OF PROBLEM No consensus exists concerning the acceptable ranges of marginal fit for lithium disilicate crowns fabricated with either heat-pressing techniques or computer-aided design and computer-aided manufacturing (CAD/CAM) systems. PURPOSE The purpose of the study was to evaluate with micro-computed tomography the marginal fit of lithium disilicate crowns fabricated with different chairside CAD/CAM systems (Cerec or E4D) or the heat-pressing technique. MATERIAL AND METHODS Lithium disilicate crowns were fabricated to fit an in vitro cast of a single human premolar. Three fabrication techniques were used: digital impressions with Cerec 3D Bluecam scanner with titanium dioxide powder, followed by milling from IPS e.max CAD for Cerec; digital impressions with E4D Laser scanner without powder, followed by milling from IPS e.max CAD for E4D; and fabrication from IPS e.max Press by using the lost-wax and heat-pressing techniques. Each crown was fixed to the cast and scanned with micro-computed tomography to obtain 52 images for measuring the vertical and horizontal fit. Data were statistically analyzed by 1-way ANOVA, followed by the Tukey honestly significant difference test (α=.05). RESULTS The mean values of vertical misfit were 36.8 ±13.9 μm for the heat-pressing group and 39.2 ±8.7 μm for the Cerec group, which were significantly smaller values than for the E4D group at 66.9 ±31.9 μm (P=.046). The percentage of crowns with a vertical misfit <75 μm was 83.8% for Cerec and heat-pressing, whereas this value was 65% for E4D. Both types of horizontal misfit (underextended and overextended) were 49.2% for heat-pressing, 50.8% for Cerec, and 58.8% for E4D. CONCLUSIONS Lithium disilicate crowns fabricated by using the Cerec 3D Bluecam scanner CAD/CAM system or the heat-pressing technique exhibited a significantly smaller vertical misfit than crowns fabricated by using an E4D Laser scanner CAD/CAM system.

[1]  B. Lang,et al.  Precision of fit: the Procera AllCeram crown. , 1998, The Journal of prosthetic dentistry.

[2]  Li Lu 鲁 莉,et al.  An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software , 2011, Journal of Huazhong University of Science and Technology [Medical Sciences].

[3]  Mathieu Contrepois,et al.  Marginal adaptation of ceramic crowns: a systematic review. , 2013, The Journal of prosthetic dentistry.

[4]  A Ender,et al.  Accuracy testing of a new intraoral 3D camera. , 2009, International journal of computerized dentistry.

[5]  D R Davis,et al.  Comparison of fit of two types of all-ceramic crowns. , 1988, The Journal of prosthetic dentistry.

[6]  Raquel C. Oyagüe,et al.  Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles , 2010, Odontology.

[7]  J. Hodolic,et al.  Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns , 2012 .

[8]  R P Chappell,et al.  Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. , 1990, The Journal of prosthetic dentistry.

[9]  L Pröbster,et al.  Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. , 2000, The Journal of prosthetic dentistry.

[10]  J Robert Kelly,et al.  Two imaging techniques for 3D quantification of pre-cementation space for CAD/CAM crowns. , 2010, Journal of dentistry.

[11]  W. Mörmann The evolution of the CEREC system. , 2006, Journal of the American Dental Association.

[12]  Dennis J Fasbinder,et al.  A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report. , 2010, Journal of the American Dental Association.

[13]  Daniel Edelhoff,et al.  Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. , 2008, Dental materials journal.

[14]  Kyu-Bok Lee,et al.  Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. , 2008, Dental materials journal.

[15]  Werner H. Moörmann The evolution of the CEREC system , 2006 .

[16]  Stavros Pelekanos,et al.  X-ray microtomographic evaluation of the influence of two preparation types on marginal fit of CAD/CAM alumina copings: a pilot study. , 2012, The International journal of prosthodontics.

[17]  R. Frankenberger,et al.  Adhesive luting revisited: influence of adhesive, temporary cement, cavity cleaning, and curing mode on internal dentin bond strength. , 2007, The journal of adhesive dentistry.

[18]  Shusheng Liu,et al.  An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software , 2011, Journal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban.

[19]  Ignace Naert,et al.  Precision of fit and clinical evaluation of all‐ceramic full restorations followed between 0·5 and 5 years , 2005 .

[20]  D. Seo,et al.  The effect of preparation designs on the marginal and internal gaps in Cerec3 partial ceramic crowns. , 2009, Journal of dentistry.

[21]  J Chai,et al.  A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. , 1997, The International journal of prosthodontics.

[22]  S C Bayne,et al.  Marginal fit of castable ceramic crowns. , 1992, The Journal of prosthetic dentistry.

[23]  Arndt Guentsch,et al.  Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility. , 2012, Dental materials : official publication of the Academy of Dental Materials.

[24]  Ignace Naert,et al.  Computer-aided designed/computer-assisted manufactured composite resin versus ceramic single-tooth restorations: a 3-year clinical study. , 2010, The International journal of prosthodontics.

[25]  Yijin Ren,et al.  Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology , 2012, PloS one.

[26]  A. Zaimoğlu,et al.  Influence of marginal fit and cement types on microleakage of all-ceramic crown systems. , 2011, Brazilian oral research.

[27]  Stefan Wolfart,et al.  Clinical results of lithium-disilicate crowns after up to 9 years of service , 2012, Clinical Oral Investigations.

[28]  J. Mclean,et al.  The estimation of cement film thickness by an in vivo technique , 1971, British Dental Journal.

[29]  Jack I Nicholls,et al.  Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. , 2010, The Journal of prosthetic dentistry.

[30]  Jack L Ferracane,et al.  Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D. , 2010, Operative dentistry.

[31]  Altay Uludamar,et al.  Internal and marginal adaptation of pressable and computer-aided design/computer-assisted manufacture onlay restorations. , 2012, The International journal of prosthodontics.

[32]  G. Tysowsky The science behind lithium disilicate: a metal-free alternative. , 2009, Dentistry today.

[33]  Jason A Griggs,et al.  Adaptation of all-ceramic fixed partial dentures. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[34]  O. Inan,et al.  Evaluation of marginal fit of two all-ceramic copings with two finish lines , 2012, European Journal of Dentistry.

[35]  T. Gerds,et al.  Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation. , 2006, Journal of the American Dental Association.

[36]  A. Keshvad,et al.  Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques. , 2011, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[37]  S. Reich,et al.  Marginal fit of heat-pressed vs. CAD/CAM processed all-ceramic onlays using a milling unit prototype. , 2008, Operative dentistry.

[38]  J A Sorensen,et al.  A rationale for comparison of plaque-retaining properties of crown systems. , 1989, The Journal of prosthetic dentistry.

[39]  Stavros Pelekanos,et al.  Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings. , 2009, The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry.

[40]  S. Ringer,et al.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[41]  Sunghuen Kim,et al.  Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns , 2010, The journal of advanced prosthodontics.

[42]  S A Aquilino,et al.  Tooth preparations for complete crowns: an art form based on scientific principles. , 2001, The Journal of prosthetic dentistry.

[43]  Alain Vanheusden,et al.  Fit of single tooth zirconia copings: comparison between various manufacturing processes. , 2011, The Journal of prosthetic dentistry.

[44]  Walter Renne,et al.  Predicting marginal fit of CAD/CAM crowns based on the presence or absence of common preparation errors. , 2012, The Journal of prosthetic dentistry.

[45]  Hesham A. Ezzat,et al.  Accuracy of ceramic restorations made with two CAD/CAM systems. , 2013, The Journal of prosthetic dentistry.

[46]  C. Wyatt,et al.  A comparison of the marginal fit of crowns fabricated with digital and conventional methods. , 2014, The Journal of prosthetic dentistry.