Sensitivity and specificity of single-nucleotide polymorphism scanning by high-resolution melting analysis.

BACKGROUND Screening for heterozygous sequence changes in PCR products, also known as "mutation scanning", is an important tool for genetic research and clinical applications. Conventional methods require a separation step. METHODS We evaluated the sensitivity and specificity of homogeneous scanning, using a saturating DNA dye and high-resolution melting. Heterozygous single-nucleotide polymorphism (SNP) detection was studied in three different sequence backgrounds of 40%, 50%, and 60% GC content. PCR products of 50-1000 bp were generated in the presence of LCGreen I. After fluorescence normalization and temperature overlay, melting curve shape was used to judge the presence or absence of heterozygotes among 1632 cases. RESULTS For PCR products of 300 bp or less, all 280 heterozygous and 296 wild-type cases were correctly called without error. In 672 cases between 400 and 1000 bp with the mutation centered, the sensitivity and specificity were 96.1% and 99.4%, respectively. When the sequence background and product size with the greatest error rate were used, the sensitivity of off-center SNPs (384 cases) was 95.6% with a specificity of 99.4%. Most false negatives occurred with SNPs that were compared with an A or T wild type sequence. CONCLUSIONS High-resolution melting analysis with the dye LCGreen I identifies heterozygous single-base changes in PCR products with a sensitivity and specificity comparable or superior to nonhomogeneous techniques. The error rate of scanning depends on the PCR product size and the type of base change, but not on the position of the SNP. The technique requires only PCR reagents, the dye LCGreen I, and 1-2 min of closed-tube, post-PCR analysis.

[1]  C. N. Gundry,et al.  Amplicon melting analysis with labeled primers: a closed-tube method for differentiating homozygotes and heterozygotes. , 2003, Clinical chemistry.

[2]  P. Green,et al.  Base-calling of automated sequencer traces using phred. I. Accuracy assessment. , 1998, Genome research.

[3]  Elaine Lyon,et al.  Genotyping of single-nucleotide polymorphisms by high-resolution melting of small amplicons. , 2004, Clinical chemistry.

[4]  A. Nataraj,et al.  Use of DNA toolbox for the characterization of mutation scanning methods. II: Evaluation of single‐strand conformation polymorphism analysis , 1999, Electrophoresis.

[5]  S. Tripp,et al.  Detection of c-kit-activating mutations in gastrointestinal stromal tumors by high-resolution amplicon melting analysis. , 2004, American journal of clinical pathology.

[6]  N. Longo,et al.  Rapid, comprehensive screening of the human medium chain acyl-CoA dehydrogenase gene. , 2004, Molecular genetics and metabolism.

[7]  Carl T Wittwer,et al.  High-resolution genotyping by amplicon melting analysis using LCGreen. , 2003, Clinical chemistry.

[8]  T. Sekiya,et al.  Detection of polymorphisms of human DNA by gel electrophoresis as single-strand conformation polymorphisms. , 1989, Proceedings of the National Academy of Sciences of the United States of America.

[9]  P. Oefner,et al.  Denaturing high‐performance liquid chromatography: A review , 2001, Human mutation.

[10]  Stephen A. Bustin,et al.  Real-Time PCR , 2005 .

[11]  L. Lerman,et al.  Computational simulation of DNA melting and its application to denaturing gradient gel electrophoresis. , 1987, Methods in enzymology.

[12]  Zhaowei Liu,et al.  Integrated platform for detection of DNA sequence variants using capillary array electrophoresis , 2002, Electrophoresis.

[13]  V. Burland,et al.  Use of a DNA toolbox for the characterization of mutation scanning methods. I: Construction of the toolbox and evaluation of heteroduplex analysis , 1999, Electrophoresis.

[14]  C. Wittwer,et al.  Fluorescein-labeled oligonucleotides for real-time pcr: using the inherent quenching of deoxyguanosine nucleotides. , 2001, Analytical biochemistry.

[15]  C. Wittwer,et al.  High-resolution DNA melting curve analysis to establish HLA genotypic identity. , 2004, Tissue antigens.

[16]  C. Wittwer,et al.  Closed-tube genotyping with unlabeled oligonucleotide probes and a saturating DNA dye. , 2004, Clinical chemistry.

[17]  C. Wittwer,et al.  Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR. , 1997, Clinical chemistry.

[18]  Edward R. Ashwood,et al.  Tietz Textbook of Clinical Chemistry and Molecular Diagnostics , 2005 .