A study on multi-nozzle arrangement for spray cooling system in natural draft dry cooling tower
暂无分享,去创建一个
Xiaoxiao Li | Hal Gurgenci | Kamel Hooman | Yubiao Sun | Zhiqiang Guan | Z. Guan | Yubiao Sun | K. Hooman | H. Gurgenci | Xiaoxiao Li
[1] W. Sirignano,et al. Fluid Dynamics and Transport of Droplets and Sprays , 1999 .
[2] C. Crowe,et al. The Particle-Source-In Cell (PSI-CELL) Model for Gas-Droplet Flows , 1977 .
[3] Boyin Zhang,et al. A study of the unfavorable effects of wind on the cooling efficiency of dry cooling towers , 1995 .
[4] Mustapha Chaker. Key Parameters for the Performance of Impaction-Pin Nozzles Used in Inlet Fogging of Gas Turbine Engines , 2007 .
[5] Junjie Yan,et al. Droplet dispersion characteristics of the hollow cone sprays in crossflow , 2013 .
[6] Yan Li,et al. Numerical study on the cooling performance of natural draft dry cooling tower with vertical delta radiators under constant heat load , 2015 .
[7] Ingo Jahn,et al. Nozzle arrangement effect on cooling performance of saline water spray cooling , 2016 .
[8] Xi Jiang,et al. Physical modelling and advanced simulations of gas―liquid two-phase jet flows in atomization and sprays , 2010 .
[9] H. Montazeri,et al. Evaporative cooling by water spray systems: CFD simulation, experimental validation and sensitivity analysis , 2015 .
[10] S. W. Park,et al. Rainfall characteristics and their relation to splash erosion , 1983 .
[11] Said Elgobashi,et al. An Updated Classification Map of Particle-Laden Turbulent Flows , 2006 .
[12] Antonio Sánchez Kaiser,et al. NUMERICAL MODEL OF EVAPORATIVE COOLING PROCESSES IN A NEW TYPE OF COOLING TOWER , 2005 .
[13] J. D. Sartor,et al. Prediction and Measurement of the Accelerated Motion of Water Drops in Air , 1975 .
[14] Bjarne Husted,et al. Comparison of PIV and PDA droplet velocity measurement techniques on two high-pressure water mist nozzles , 2009 .
[15] W. M. Robertson,et al. The effects of spray-chilling carcasses on the shrinkage and quality of beef. , 1988, Meat science.
[16] Hal Gurgenci,et al. CFD analysis of pre-cooling water spray system in natural draft dry cooling towers , 2016 .
[17] Suoying He,et al. Numerical simulation of water spray for pre-cooling of inlet air in natural draft dry cooling towers , 2013 .
[18] W. E. Ranz,et al. Evaporation from drops , 1952 .
[19] Mehmet Kanoglu,et al. Improving the performance of an existing air-cooled binary geothermal power plant : A case study , 1999 .
[20] S. A. Morsi,et al. An investigation of particle trajectories in two-phase flow systems , 1972, Journal of Fluid Mechanics.
[21] Cyrus B. Meher-Homji,et al. Inlet Fogging of Gas Turbine Engines—Part I: Fog Droplet Thermodynamics, Heat Transfer, and Practical Considerations , 2004 .
[22] M. D. Su,et al. Numerical simulation of fluid flow and thermal performance of a dry-cooling tower under cross wind condition , 1999 .
[23] Ingo Jahn,et al. An investigation on spray cooling using saline water with experimental verification , 2016 .
[24] A. Stilgoe,et al. A theoretical model with experimental verification for heat and mass transfer of saline water droplets , 2015 .
[25] Z. Guan,et al. Investigation on the influence of injection direction on the spray cooling performance in natural draft dry cooling tower , 2017 .
[26] W. Sirignano,et al. Fluid Dynamics and Transport of Droplets and Sprays: Index , 2010 .
[27] Detlev G. Kröger,et al. Performance evaluation of dry-cooling systems for power plant applications , 1996 .
[28] Antonio Peretto,et al. CFD Simulation of Water Injection in GT Inlet Duct Using Spray Experimentally Tuned Data: Nozzle Spray Simulation Model and Results for an Application to a Heavy-Duty Gas Turbine , 2007 .
[29] A. Lefebvre. Atomization and Sprays , 1988 .
[30] Antonio Sánchez Kaiser,et al. On the influence of psychrometric ambient conditions on cooling tower drift deposition , 2010 .
[31] B. Launder,et al. Lectures in mathematical models of turbulence , 1972 .
[32] Xiaoze Du,et al. Dimensional characteristics of wind effects on the performance of indirect dry cooling system with vertically arranged heat exchanger bundles , 2013 .
[33] Suoying He,et al. Water spray for pre-cooling of inlet air for Natural Draft Dry Cooling Towers – Experimental study , 2015 .
[34] Suoying He,et al. Pre-cooling with Munters media to improve the performance of Natural Draft Dry Cooling Towers , 2013 .
[35] D. Costenaro,et al. Assessment of Evaporative Cooling Enhancement Methods for Air-Cooled Geothermal Power Plants , 2002 .
[36] Cyrus B. Meher-Homji,et al. Inlet Fogging of Gas Turbine Engines—Part III: Fog Behavior in Inlet Ducts, Computational Fluid Dynamics Analysis, and Wind Tunnel Experiments , 2004 .
[37] Cyrus B. Meher-Homji,et al. Inlet fogging of gas turbine engines. Part II: Fog droplet sizing analysis, nozzle types, measurement, and testing , 2004 .
[38] Yan Li,et al. Numerical study on the cooling performance of dry cooling tower with vertical two-pass column radiators under crosswind , 2015 .
[39] Detlev G. Kröger,et al. Performance optimization of dry-cooling systems for power plants through SQP methods , 1998 .
[40] Ting Wang,et al. Simulation of Mist Transport for Gas Turbine Inlet Air Cooling , 2004 .
[41] P. Boulet,et al. Air cooling by evaporating droplets in the upward flow of a condenser , 2011 .
[42] T. S. Dhanasekaran,et al. Calibration of a Computational Model to Predict Mist/Steam Impinging Jets Cooling With an Application to Gas Turbine Blades , 2010 .
[43] Ebrahim Rezaei,et al. Reducing water consumption of an industrial plant cooling unit using hybrid cooling tower , 2010 .