Vesicoureteral Reflux in Children: A Phantom Study of Microwave Heating and Radiometric Thermometry of Pediatric Bladder

We have investigated the use of microwave heating and radiometry to safely heat urine inside a pediatric bladder. The medical application for this research is to create a safe and reliable method to detect vesicoureteral reflux, a pediatric disorder, where urine flow is reversed and flows from the bladder back up into the kidney. Using fat and muscle tissue models, we have performed both experimental and numerical simulations of a pediatric bladder model using planar dual concentric conductor microstrip antennas at 915 MHz for microwave heating. A planar elliptical antenna connected to a 500 MHz bandwidth microwave radiometer centered at 3.5 GHz was used for noninvasive temperature measurement inside tissue. Temperatures were measured in the phantom models at points during the experiment with implanted fiberoptic sensors, and 2-D distributions in cut planes at depth in the phantom with an infrared camera at the end of the experiment. Cycling between 20 s with 20 Watts power for heating, and 10 s without power to allow for undisturbed microwave radiometry measurements, the experimental results show that the target tissue temperature inside the phantom increases fast and that the radiometer provides useful measurements of spatially averaged temperature of the illuminated volume. The presented numerical and experimental results show excellent concordance, which confirms that the proposed system for microwave heating and radiometry is applicable for safe and reliable heating of pediatric bladder.

[1]  Svein K. Jacobsen,et al.  Nonparametric 1-D temperature restoration in lossy media using Tikhonov regularization on sparse radiometry data , 2003, IEEE Transactions on Biomedical Engineering.

[2]  R. Taschereau,et al.  Combination applicator for simultaneous heat and radiation , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[4]  Kavitha Arunachalam,et al.  Size reduction and radiation pattern shaping of multi-fed DCC slot antennas used in conformal microwave array hyperthermia applicators , 2009, BiOS.

[5]  M. J. Richardson,et al.  New materials for dielectric simulation of tissues. , 1991, Physics in medicine and biology.

[6]  P. Staufer,et al.  Effect of complex bolus-tissue load configurations on SAR distributions from dual concentric conductor applicators , 1999, IEEE Transactions on Biomedical Engineering.

[7]  C J Schneider,et al.  SAR characteristics of three types of Contact Flexible Microstrip Applicators for superficial hyperthermia. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[8]  A D Edwards,et al.  Monitoring of deep brain temperature in infants using multi-frequency microwave radiometry and thermal modelling. , 2001, Physics in medicine and biology.

[9]  Kavitha Arunachalam,et al.  Modeling the detectability of vesicoureteral reflux using microwave radiometry , 2010, Physics in medicine and biology.

[10]  A. Tennant,et al.  A robot-controlled microwave antenna system for uniform hyperthermia treatment of superficial tumours with arbitrary shape. , 1990, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  O Klemetsen,et al.  Non-invasive vesicoureteral reflux detection: heating risk studies for a new device. , 2011, Journal of pediatric urology.

[12]  Kavitha Arunachalam,et al.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[13]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[14]  G C van Rhoon,et al.  A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[15]  B. Efron The jackknife, the bootstrap, and other resampling plans , 1987 .

[16]  A. W. Guy,et al.  Analyses of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom Models , 1971 .

[17]  Richard K. Moore,et al.  Microwave remote sensing fundamentals and radiometry , 1981 .

[18]  R. Dicke The measurement of thermal radiation at microwave frequencies. , 1946, The Review of scientific instruments.

[19]  Waldemar Wlodarczyk,et al.  A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom. , 2005, International journal of radiation oncology, biology, physics.

[20]  P. Stauffer,et al.  Radiation patterns of dual concentric conductor microstrip antennas for superficial hyperthermia , 1998, IEEE Transactions on Biomedical Engineering.

[21]  H. Paltiel,et al.  Enhanced detection of vesicoureteral reflux in infants and children with use of cyclic voiding cystourethrography. , 1992, Radiology.

[22]  R. Issels Hyperthermia Combined with Chemotherapy – Biological Rationale, Clinical Application, and Treatment Results , 1999, Oncology Research and Treatment.

[23]  Michael B. Taylor,et al.  Non-invasive vesicoureteral reflux imaging. , 2010, Journal of pediatric urology.

[24]  Toshifumi Sugiura,et al.  Recent Trends in Medical Microwave Radiometry , 1995 .

[25]  Sindre Holsbøe Brelum A numerical study of planar elliptical antennas applied to ultrawideband (UWB) imaging of breast tissue , 2008 .

[26]  Kavitha Arunachalam,et al.  Detection of Vesicoureteral Reflux Using Microwave Radiometry—System Characterization With Tissue Phantoms , 2011, IEEE Transactions on Biomedical Engineering.

[27]  J. Overgaard,et al.  Randomised trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma , 1995, The Lancet.

[28]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries , 2007, Physics in medicine and biology.

[29]  Harm H. Kampinga,et al.  Kadota Fund International Forum 2004. Application of thermal stress for the improvement of health, 15–18 June 2004, Awaji Yumebutai International Conference Center, Awaji Island, Hyogo, Japan. Final Report , 2008, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[30]  Paul R Stauffer,et al.  Can we settle with single-band radiometric temperature monitoring during hyperthermia treatment of chestwall recurrence of breast cancer using a dual-mode transceiving applicator? , 2007, Physics in medicine and biology.

[31]  Kung-Shan Cheng,et al.  Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. , 2009, Medical physics.

[32]  G C van Rhoon,et al.  Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[33]  Kavitha Arunachalam,et al.  Microwave radiometry for non-invasive detection of vesicoureteral reflux (VUR) following bladder warming , 2011, BiOS.

[34]  P. Stauffer,et al.  Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia , 2009, Physics in medicine and biology.

[35]  J. MacFall,et al.  Application of new technology in clinical hyperthermia. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[36]  O Klemetsen,et al.  DESIGN OF MEDICAL RADIOMETER FRONT-END FOR IMPROVED PERFORMANCE. , 2011, Progress in electromagnetics research B. Pier B.