Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples.

The single-run resolving power of current 10 μm id porous-layer open-tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene-co-divinylbenzene) porous layer (~0.75 μm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set-ups, SPE-PLOT-LC-MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combinations was undertaken. Maximum resolution for <400 bar was achieved using a 40 nL/min flow rate, a 400 min gradient and an 8 m long column. We obtained a 2.3-fold increase in peak capacity compared to previous PLOT studies (950 versus previously obtained 400, when using peak width = 2σ definition). Our system also meets or surpasses peak capacities obtained in recent reports using nano-ultra-performance LC conditions or long silica monolith nanocolumns. Nearly 500 proteins (1958 peptides) could be identified in just one single injection of an extract corresponding to 1000 BxPC3 beta catenin (-/-) cells, and ~1200 and 2500 proteins in extracts of 10,000 and 100,000 cells, respectively, allowing detection of central members and regulators of the Wnt signaling pathway.

[1]  Marc W. Kirschner,et al.  Tankyrase inhibition stabilizes axin and antagonizes Wnt signalling , 2009, Nature.

[2]  B. Paull,et al.  In-process phase growth measurement technique in the fabrication of monolithic porous layer open tubular (monoPLOT) columns using capacitively coupled contactless conductivity. , 2013, The Analyst.

[3]  T. Greibrokk,et al.  High efficiency, high temperature separations on silica based monolithic columns. , 2011, Journal of chromatography. A.

[4]  A. Shchukarev,et al.  A study of surface modification and anchoring techniques used in the preparation of monolithic microcolumns in fused silica capillaries. , 2006, Journal of separation science.

[5]  P. Carr,et al.  A practical approach to maximizing peak capacity by using long columns packed with pellicular stationary phases for proteomic research. , 2006, Journal of chromatography. A.

[6]  T. Köcher,et al.  Ultra-high-pressure RPLC hyphenated to an LTQ-Orbitrap Velos reveals a linear relation between peak capacity and number of identified peptides. , 2011, Analytical chemistry.

[7]  T. Rejtar,et al.  Ultrasensitive characterization of site-specific glycosylation of affinity-purified haptoglobin from lung cancer patient plasma using 10 μm i.d. porous layer open tubular liquid chromatography-linear ion trap collision-induced dissociation/electron transfer dissociation mass spectrometry. , 2011, Analytical chemistry.

[8]  E. Fogelqvist,et al.  Coupling of open tubular liquid chromatography to electrospray mass spectrometry with a nanospray interface , 1999 .

[9]  T. Greibrokk,et al.  Separation of intact proteins on porous layer open tubular (PLOT) columns. , 2010, Journal of chromatography. A.

[10]  A. Jaiswal,et al.  Adenomatous polyposis coli interacts with flap endonuclease 1 to block its nuclear entry and function. , 2012, Neoplasia.

[11]  Dwight R Stoll,et al.  Peak capacity optimization of peptide separations in reversed-phase gradient elution chromatography: fixed column format. , 2006, Analytical chemistry.

[12]  R. Aebersold,et al.  Large-scale quantitative assessment of different in-solution protein digestion protocols reveals superior cleavage efficiency of tandem Lys-C/trypsin proteolysis over trypsin digestion. , 2012, Journal of proteome research.

[13]  G. Guiochon The limits of the separation power of unidimensional column liquid chromatography. , 2006, Journal of chromatography. A.

[14]  Ronald J. Moore,et al.  Automated 20 kpsi RPLC-MS and MS/MS with chromatographic peak capacities of 1000-1500 and capabilities in proteomics and metabolomics. , 2005, Analytical chemistry.

[15]  L. Deterding,et al.  Optimization of a Coaxial Continuous Flow Fast Atom Bombardment Interface between Capillary Liquid Chromatography and Magnetic Sector Mass Spectrometry for the Analysis of Biomolecules , 1989 .

[16]  G. Desmet,et al.  Parameters affecting the separation of intact proteins in gradient-elution reversed-phase chromatography using poly(styrene-co-divinylbenzene) monolithic capillary columns. , 2010, Journal of chromatography. A.

[17]  Richard D. Smith,et al.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics. , 2002, Analytical chemistry.

[18]  Gerard J. M. Bruin,et al.  Optimization and evaluation of the performance of arrangements for UV detection in high-resolution separations using fused-silica capillaries , 1991 .

[19]  P. Schoenmakers,et al.  Fabrication of columns for open-tubular liquid chromatography using photopolymerization of acrylates , 1990 .

[20]  S. Mohammed,et al.  In-house construction of a UHPLC system enabling the identification of over 4000 protein groups in a single analysis. , 2012, The Analyst.

[21]  G. Guiochon,et al.  Correlation between peak capacity and protein sequence coverage in proteomics analysis by liquid chromatography-mass spectrometry/mass spectrometry. , 2010, Journal of chromatography. A.

[22]  M. Macka,et al.  Monolithic porous layer open tubular (monoPLOT) columns for low pressure liquid chromatography of proteins. , 2011, Analytical methods : advancing methods and applications.

[23]  T. Tsuda,et al.  Studies of open-tubular micro-capillary liquid chromatography: II. Chemically bonded octadecylsilane stationary phase , 1978 .

[24]  H. Kolmar,et al.  Performance evaluation of thick film open tubular silica capillary by reversed phase liquid chromatography. , 2013, Journal of chromatography. A.

[25]  Jian Zhang,et al.  Ultratrace LC/MS proteomic analysis using 10-microm-i.d. Porous layer open tubular poly(styrene-divinylbenzene) capillary columns. , 2007, Analytical chemistry.

[26]  Masaru Tomita,et al.  One-dimensional capillary liquid chromatographic separation coupled with tandem mass spectrometry unveils the Escherichia coli proteome on a microarray scale. , 2010, Analytical chemistry.

[27]  F. Švec Preparation and HPLC applications of rigid macroporous organic polymer monoliths. , 2004, Journal of separation science.

[28]  M. Pelzing,et al.  Investigation of carryover of peptides in nano-liquid chromatography/mass spectrometry using packed and monolithic capillary columns. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[29]  G. Guiochon,et al.  Use of open-tubular columns in liquid chromatography , 1984 .

[30]  K. Nakanishi,et al.  Performance evaluation of long monolithic silica capillary columns in gradient liquid chromatography using peptide mixtures. , 2011, Journal of chromatography. A.

[31]  G. Baron,et al.  General rules for the optimal external porosity of LC supports. , 2004, Analytical chemistry.

[32]  Peter Dirks,et al.  Cancer stem cells: an evolving concept , 2012, Nature Reviews Cancer.

[33]  E. Hilder,et al.  Kinetic optimisation of open-tubular liquid-chromatography capillaries coated with thick porous layers for increased loadability. , 2011, Journal of chromatography. A.

[34]  Soga,et al.  Performance of a monolithic silica column in a capillary under pressure-driven and electrodriven conditions , 2000, Analytical chemistry.

[35]  D. DeVoe,et al.  Proteome analysis of microdissected tumor tissue using a capillary isoelectric focusing-based multidimensional separation platform coupled with ESI-tandem MS. , 2005, Analytical chemistry.

[36]  Keqi Tang,et al.  Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes. , 2004, Accounts of chemical research.

[37]  G. Desmet,et al.  High-resolution separations of tryptic digest mixtures using core-shell particulate columns operated at 1,200 bar. , 2012, Journal of chromatography. A.

[38]  R. Swart,et al.  RECENT PROGRESS IN OPEN TUBULAR LIQUID CHROMATOGRAPHY , 1997 .

[39]  James W. Jorgenson,et al.  Liquid chromatography in open-tubular columns : Theory of column optimization with limited pressure and analysis time, and fabrication of chemically bonded reversed-phase columns on etched borosilicate glass capillaries , 1983 .

[40]  F. Švec,et al.  Stability and repeatability of capillary columns based on porous monoliths of poly(butyl methacrylate-co-ethylene dimethacrylate). , 2007, Journal of chromatography. A.

[41]  Dipak Thakur,et al.  Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry. , 2011, Journal of chromatography. A.

[42]  H. Kolmar,et al.  Synthesis and characterization of new generation open tubular silica capillaries for liquid chromatography. , 2012, Journal of chromatography. A.

[43]  G. J. Jong,et al.  Potential of long capillary monolithic columns for the analysis of protein digests. , 2009 .

[44]  M. Georgescu,et al.  Moesin is a glioma progression marker that induces proliferation and Wnt/β-catenin pathway activation via interaction with CD44. , 2013, Cancer research.

[45]  K. Prydz,et al.  N-Glycan synthesis in the apical and basolateral secretory pathway of epithelial MDCK cells and the influence of a glycosaminoglycan domain. , 2011, Glycobiology.

[46]  Guihua Yue,et al.  On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-microm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis. , 2007, Analytical chemistry.

[47]  Naoyuki Sugiyama,et al.  Human proteome analysis by using reversed phase monolithic silica capillary columns with enhanced sensitivity. , 2012, Journal of chromatography. A.

[48]  Richard D. Smith,et al.  MicroSPE-nanoLC-ESI-MS/MS using 10-microm-i.d. silica-based monolithic columns for proteomics. , 2007, Analytical chemistry.