A Modified Surface on Titanium Deposited by a Blasting Process

Hydroxyapatite (HA) coating of hard tissue implants is widely employed for its biocompatible and osteoconductive properties as well as its improved mechanical properties. Plasma technology is the principal deposition process for coating HA on bioactive metals for this application. However, thermal decomposition of HA can occur during the plasma deposition process, resulting in coating variability in terms of purity, uniformity and crystallinity, which can lead to implant failure caused by aseptic loosening. In this study, CoBlastTM, a novel blasting process has been used to successfully modify a titanium (V) substrate with a HA treatment using a dopant/abrasive regime. The impact of a series of apatitic abrasives under the trade name MCD, was investigated to determine the effect of abrasive particle size on the surface properties of both microblast (abrasive only) and CoBlast (HA/abrasive) treatments. The resultant HA treated substrates were compared to substrates treated with abrasive only (microblasted) and an untreated Ti. The HA powder, apatitic abrasives and the treated substrates were characterized for chemical composition, coating coverage, crystallinity and topography including surface roughness. The results show that the surface roughness of the HA blasted modification was affected by the particle size of the apatitic abrasives used. The CoBlast process did not alter the chemistry of the crystalline HA during deposition. Cell proliferation on the HA surface was also assessed, which demonstrated enhanced osteo-viability compared to the microblast and blank Ti. This study demonstrates the ability of the CoBlast process to deposit HA coatings with a range of surface properties onto Ti substrates. The ability of the CoBlast technology to offer diversity in modifying surface topography offers exciting new prospects in tailoring the properties of medical devices for applications ranging from dental to orthopedic settings.

[1]  A. Crean,et al.  Deposition of substituted apatites with anticolonizing properties onto titanium surfaces using a novel blasting process. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[2]  B. Meenan,et al.  Biological responses to hydroxyapatite surfaces deposited via a co-incident microblasting technique. , 2010, Biomaterials.

[3]  L. Sexton,et al.  Deposition of substituted apatites onto titanium surfaces using a novel blasting process , 2009 .

[4]  Hong Li,et al.  Characterization of plasma sprayed hydroxyapatite/ZrO2 graded coating , 2009 .

[5]  M. Fathi,et al.  Preparation and bioactivity evaluation of bone-like hydroxyapatite nanopowder , 2008 .

[6]  T. Webster,et al.  Nano rough micron patterned titanium for directing osteoblast morphology and adhesion , 2008, International journal of nanomedicine.

[7]  R. Legeros,et al.  Early Tissue Response to Modified Implant Surfaces Using Back Scattered Imaging , 2007, Implant dentistry.

[8]  Se-Bum Paik,et al.  Crystalline hydroxyapatite thin films produced at room temperature - An opposing radio frequency magnetron sputtering approach , 2007 .

[9]  Josep A Planell,et al.  The effect of shot blasting and heat treatment on the fatigue behavior of titanium for dental implant applications. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[10]  G. Monteil,et al.  Friction and wear behaviour of cp Ti and Ti6Al4V following nitric acid passivation , 2006 .

[11]  R. Heimann,et al.  Formation and transformation of amorphous calcium phosphates on titanium alloy surfaces during atmospheric plasma spraying and their subsequent in vitro performance. , 2006, Biomaterials.

[12]  Maxence Bigerelle,et al.  A kinetic approach to osteoblast adhesion on biomaterial surface. , 2005, Journal of biomedical materials research. Part A.

[13]  L. Rimondini,et al.  Physical characterization of different-roughness titanium surfaces, with and without hydroxyapatite coating, and their effect on human osteoblast-like cells. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[14]  Takeshi Higashiguchi,et al.  Poly-crystallized hydroxyapatite coating deposited by pulsed laser deposition method at room temperature , 2005 .

[15]  N. Nomura,et al.  Microstructures and bond strengths of plasma-sprayed hydroxyapatite coatings on porous titanium substrates , 2005, Journal of materials science. Materials in medicine.

[16]  E. Długoń,et al.  Sol–gel derived hydroxyapatite coatings on titanium and its alloy Ti6Al4V , 2005 .

[17]  H. Varma,et al.  Synthesis of calcium phosphate bioceramics by citrate gel pyrolysis method , 2005 .

[18]  Maxence Bigerelle,et al.  Statistical correlation between cell adhesion and proliferation on biocompatible metallic materials. , 2005, Journal of biomedical materials research. Part A.

[19]  Yu-peng Lu,et al.  Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate. , 2004, Biomaterials.

[20]  U. Gbureck,et al.  Tribochemical structuring and coating of implant metal surfaces with titanium oxide and hydroxyapatite layers , 2003 .

[21]  真野 隆充 Initial tissue response to a titanium implant coated with apatite at room temperature using a blast coating method , 2002 .

[22]  A. Rakowska,et al.  Electrophoretic coating of hydroxyapatite on titanium implants , 2001 .

[23]  L. Cooper,et al.  Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model. , 2001, The Journal of prosthetic dentistry.

[24]  K A Gross,et al.  Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: a review. , 2001, Journal of biomedical materials research.

[25]  K. Anselme,et al.  Osteoblast adhesion on biomaterials. , 2000, Biomaterials.

[26]  D. Anderson Coatings. , 1999, Analytical chemistry.

[27]  K A Gross,et al.  Thermal processing of hydroxyapatite for coating production. , 1998, Journal of biomedical materials research.

[28]  C. Berndt,et al.  Amorphous phase formation in plasma-sprayed hydroxyapatite coatings. , 1998, Journal of biomedical materials research.

[29]  F. Cui,et al.  Antimicrobial effects of metal ions (Ag+, Cu2+, Zn2+) in hydroxyapatite , 1998, Journal of materials science. Materials in medicine.

[30]  J. Weng,et al.  Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluid. , 1997, Biomaterials.

[31]  T. Albrektsson,et al.  A 1-year follow-up of implants of differing surface roughness placed in rabbit bone. , 1997, The International journal of oral & maxillofacial implants.

[32]  K. Asaoka,et al.  Blast coating method: new method of coating titanium surface with hydroxyapatite at room temperature. , 1997, Journal of biomedical materials research.

[33]  K. de Groot,et al.  Microstructure and crystallinity in hydroxyapatite coatings. , 1994, Biomaterials.

[34]  R Mendelsohn,et al.  Novel infrared spectroscopic method for the determination of crystallinity of hydroxyapatite minerals. , 1991, Biophysical journal.

[35]  Racquel Z. LeGeros,et al.  7. Substrate Surface Dissolution and Interfacial Biological Mineralization , 1991 .

[36]  T. Mosmann Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. , 1983, Journal of immunological methods.