Realignment strategies for awake-monkey fMRI data.

Functional magnetic resonance imaging (fMRI) experiments with awake nonhuman primates (NHPs) have recently seen a surge of applications. However, the standard fMRI analysis tools designed for human experiments are not optimal for NHP data collected at high fields. One major difference is the experimental setup. Although real head movement is impossible for NHPs, MRI image series often contain visible motion artifacts. Animal body movement results in image position changes and geometric distortions. Since conventional realignment methods are not appropriate to address such differences, algorithms tailored specifically for animal scanning become essential. We have implemented a series of high-field NHP specific methods in a software toolbox, fMRI Sandbox (http://kyb.tuebingen.mpg.de/~stoewer/), which allows us to use different realignment strategies. Here we demonstrate the effect of different realignment strategies on the analysis of awake-monkey fMRI data acquired at high field (7 T). We show that the advantage of using a nonstandard realignment algorithm depends on the amount of distortion in the dataset. While the benefits for less distorted datasets are minor, the improvement of statistical maps for heavily distorted datasets is significant.

[1]  A M Blamire,et al.  Dynamic shim updating: A new approach towards optimized whole brain shimming , 1996, Magnetic resonance in medicine.

[2]  Amir Shmuel,et al.  Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies. , 2007, Magnetic resonance imaging.

[3]  Nikos K. Logothetis,et al.  Spin-echo fMRI of the temporal lobe in awake, behaving monkeys at 7T , 2007 .

[4]  P. Reber,et al.  Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps , 1998, Magnetic resonance in medicine.

[5]  Karl J. Friston,et al.  Spatial registration and normalization of images , 1995 .

[6]  R W Cox,et al.  Magnetic field changes in the human brain due to swallowing or speaking , 1998, Magnetic resonance in medicine.

[7]  R. S. Hinks,et al.  Real‐time shimming to compensate for respiration‐induced B0 fluctuations , 2007, Magnetic resonance in medicine.

[8]  Franck Lamberton,et al.  A new EPI‐based dynamic field mapping method: Application to retrospective geometrical distortion corrections , 2007, Journal of magnetic resonance imaging : JMRI.

[9]  G. Glover,et al.  Respiration‐induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla , 2002, Magnetic resonance in medicine.

[10]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited , 1995, NeuroImage.

[11]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[12]  Saikat Sengupta,et al.  Dynamic B0 shimming at 7 T. , 2011, Magnetic resonance imaging.

[13]  N. Logothetis,et al.  Functional imaging of the monkey brain , 1999, Nature Neuroscience.

[14]  Kevin Whittingstall,et al.  Functional magnetic resonance imaging of awake behaving macaques. , 2010, Methods.

[15]  John Duncan,et al.  Frontoparietal activity with minimal decision and control in the awake macaque at 7 T. , 2009, Magnetic resonance imaging.

[16]  Amir Shmuel,et al.  Robust controlled functional MRI in alert monkeys at high magnetic field: Effects of jaw and body movements , 2007, NeuroImage.

[17]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[18]  P. Jezzard,et al.  Sources of distortion in functional MRI data , 1999, Human brain mapping.

[19]  Nikos K. Logothetis,et al.  fMRI of the temporal lobe of the awake monkey at 7 T , 2008, NeuroImage.

[20]  Manuel Guizar-Sicairos,et al.  Efficient subpixel image registration algorithms. , 2008, Optics letters.