Replacement of a tracheal segment by a mixed graft (aorta and prosthesis): an experimental study in rabbits.

OBJECTIVE To develop a new graft and to verify its technical feasibility, viability, and ability to reduce the risk of infection by interposition of an aortic segment between the airway and the prosthetic component of the graft. DESIGN Experimental study. SETTING Multicentre study, France. ANIMALS 38 New Zealand rabbits. INTRODUCTION A 1 cm aortic segment was obtained from the thoracic aorta of a rabbit and cryopreserved or stored at +4 degrees C. The aortic segment, surrounded by a ringed expanded polytetrafluoroethylene (ePTFE) prosthesis was used to replace 1 cm of cervical trachea in two groups of rabbits, either with cryopreserved or fresh aorta. MAIN OUTCOME MEASURES Macroscopic, microbiological, and histological studies four months later. RESULTS 12/20 animals in the cryopreserved group survived and 13/18 in those had had fresh aorta inserted. Partial or total necrosis of the aortic muscular layer was replaced by connective tissue, which was a guide for epithelialisation from the anastomoses. CONCLUSION This new graft is worthy of further investigation, as it is technically feasible and easy to insert.