The point-spread function of fiber-coupled area detectors

The point-spread function (PSF) of a powdered-phosphor fiber-optic taper-coupled CCD area detector was measured, and an analytic expression for its functional form proposed. The ‘tails’ of this PSF were shown to be due almost entirely to the fiber-optic taper, with no contribution from the phosphor itself.

[1]  V. Vand,et al.  Analytical representation of atomic scattering factors , 1957 .

[2]  D. Cromer,et al.  Scattering factors computed from relativistic Dirac–Slater wave functions , 1965 .

[3]  W. H. McMaster,et al.  Compilation of x-ray cross sections UCRL-50174, sections I, II revision 1, III, IV* , 1970 .

[4]  良二 上田 J. Appl. Cryst.の発刊に際して , 1970 .

[5]  U. W. Arndt,et al.  The Rotation method in crystallography : data collection from macromolecular crystals , 1977 .

[6]  Ar Lang,et al.  International Tables for Crystallography, Vol C , 1992 .

[7]  D. Bourgeois,et al.  The point-spread function of X-ray image-intensifiers/CCD-camera and imaging-plate systems in crystallography: assessment and consequences for the dynamic range , 1994 .

[8]  D M Szebenyi,et al.  A system for integrated collection and analysis of crystallographic diffraction data. , 1997, Journal of synchrotron radiation.

[9]  A. Hald A history of mathematical statistics from 1750 to 1930 , 1998 .

[10]  E. Eikenberry,et al.  Charge-coupled device area x-ray detectors , 2002 .

[11]  SIBYLS — a SAXS and Protein Crystallography Beamline at the ALS , 2003 .

[12]  Tom Alber,et al.  Suite of three protein crystallography beamlines with single superconducting bend magnet as the source. , 2004, Journal of synchrotron radiation.

[13]  Ioannis S Kandarakis,et al.  Modeling granular phosphor screens by Monte Carlo methods. , 2006, Medical physics.

[14]  T.J. Madden,et al.  Lens-Coupled CCD Detector for X-ray Crystallography , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[15]  A. D. Moivre The Doctrine of Chances: Or a Method of Calculating the Probability of Events in Play , 2008 .

[16]  J. Holton There and back again: using simulated diffraction images to optimize data processing by ELVES , 2008 .

[17]  Robin L. Owen,et al.  Determination of X-ray flux using silicon pin diodes , 2009, Journal of synchrotron radiation.

[18]  Loes M. J. Kroon-Batenburg,et al.  EVAL15: a diffraction data integration method based on ab initio predicted profiles , 2010 .

[19]  Kenneth A. Frankel,et al.  The minimum crystal size needed for a complete diffraction data set , 2010, Acta crystallographica. Section D, Biological crystallography.