On the Measurement of Total Radiated Power in Uncalibrated Reverberation Chambers

A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.

[1]  Christopher L. Holloway,et al.  Total radiated power limits for emission measurements in a reverberation chamber , 2003, 2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446).

[2]  M. Hoijer,et al.  Maximum power available to stress onto the critical component in the equipment under test when performing a radiated susceptibility test in the reverberation chamber , 2006, IEEE Transactions on Electromagnetic Compatibility.

[3]  David A. Hill,et al.  Aperture coupling to a coaxial air line: theory and experiment , 1993 .

[4]  G. Latmiral,et al.  Performance and Analysis of a Reverberating Enclosure with Variable Geometry , 1980, IEEE Transactions on Electromagnetic Compatibility.

[5]  T RANSIENT FIELDS IN MODE-STIRRED CHAMBERS , 2002 .

[6]  C.L. Holloway,et al.  A review of dipole models for correlating emission measurements made at various EMC test facilities , 2004, 2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559).

[7]  D. Hill Plane wave integral representation for fields in reverberation chambers , 1998 .

[8]  L. R. Arnaut Statistics of the quality factor of a rectangular reverberation chamber , 2003 .

[9]  C. Papas,et al.  Electromagnetic Waveguides and Resonators , 1958 .

[10]  C. Holloway,et al.  Emission and immunity standards: replacing field-at-a-distance measurements with total-radiated-power measurements , 2001, 2001 IEEE EMC International Symposium. Symposium Record. International Symposium on Electromagnetic Compatibility (Cat. No.01CH37161).

[11]  Christopher L. Holloway,et al.  On determining the maximum emissions from electrically large sources , 2002 .

[12]  EFFECTS OF THE VARIATION OF THE EXCITATION AND BOUNDARY CONDITIONS OF MODE-STIRRED CHAMBERS AND CONSEQUENCES FOR CALIBRATION AND MEASUREMENTS , 2002 .

[13]  Galen H. Koepke,et al.  Directivity of the test device in EMC measurements , 2000, IEEE International Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.00CH37016).

[14]  Dennis G. Camell,et al.  Evaluation of the NASA Langley Research Center mode-stirred chamber facility , 1999 .