Comparative performance of disposable soft contact lenses.

A short-term clinical study was undertaken to compare and evaluate the fit and clinical behaviour of eight disposable hydrogel contact lenses. Thirty subjects were enrolled in a 1-day, randomised, double-masked study. The lenses compared were Vistakon Acuvue (8.80), Vistakon Surevue (8.80), Aspect Frequency-55, Bausch & Lomb Medalist (SeeQuence 2), Ciba Focus (8.90), Lunelle Rythmic, Pilkington Barnes Hind Precision-Wand Wesley Jessen Freshlook. Three of the eight designs, Acuvue (86.7%), Precision-UV (86.7%) and Frequency-55 (90%), achieved relatively high levels of fitting success. The Rythmic lenses achieved the lowest success rate (70%) showing significantly greater downward decentration than the other designs. Although all the lenses were designed to fit a wide variety of eyes, they exhibited widely varying fitting characteristics. Some were more successful than others. The study shows that it is necessary for practitioners to utilise a range of lens designs in order to fit satisfactorily the typical contact lens population.

[1]  M Guillon,et al.  CORNEAL TOPOGRAPHY: A CLINICAL MODEL , 1986, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[2]  B. Long,et al.  High water content versus low water content—Does monthly replacement affect the difference? , 1995 .

[3]  B. Holden,et al.  Influence of Soft Contact Lens Design on Clinical Performance , 1993, Optometry and vision science : official publication of the American Academy of Optometry.

[4]  R. T. Kame,et al.  Clinical Comparison of Corneal Diameter and Curvature in Asian Eyes with Those of Caucasian Eyes , 1992, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  D. Loran,et al.  DESIGNING CONTACT LENSES FOR ORIENTAL EYES , 1991 .

[6]  M. Guillon,et al.  Soft Contact Lens Visual Performance: A Multicenter Study , 1991, Optometry and vision science : official publication of the American Academy of Optometry.

[7]  B. Holden,et al.  A new method for measuring the diameter of the in vivo human cornea. , 1982, American journal of optometry and physiological optics.

[8]  N. Efron,et al.  Determinants of the Initial Comfort of Hydrogel Contact Lenses , 1986, American journal of optometry and physiological optics.

[9]  P. Herse,et al.  Problem of between-eye correlation for statistical hypothesis testing: rabbit corneal thickness. , 1991, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  M. Guillon,et al.  Visual performance stability of disposable contact lenses , 1993 .

[11]  M. Guillon,et al.  Clinical management of regular replacement: Part I. Selection of replacement frequency , 1992 .

[12]  John Boulos,et al.  A Unifying Parameter to Describe the Clinical Mechanics of Hydrogel Contact Lenses , 1989, Optometry and vision science : official publication of the American Academy of Optometry.

[13]  Dipti S. Shah,et al.  Influence of contact lens material surface characteristics on replacement frequency , 1994 .

[14]  I. Fatt A predictive model for dehydration of a hydrogel contact lens in the eye , 1989 .