A visual odometry base-tracking system for intraoperative C-arm guidance

C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view images, with limited quantitative functionality. Various techniques have been proposed to improve positioning, reduce radiation exposure, and provide quantitative measuring tools, all of which require accurate C-arm position tracking. While external stereo camera systems can be used for this purpose, they are typically considered too obtrusive. This paper therefore presents the development and verification of a low-profile, real-time C-arm base-tracking system using computer vision techniques. The proposed tracking system, called OPTIX (On-board Position Tracking for Intraoperative X-rays), uses a single downward-facing camera mounted to the base of a C-arm. Relative motion tracking and absolute position recovery algorithms were implemented to track motion using the visual texture in operating room floors. The accuracy of the system was evaluated in a simulated operating room mounted on a real C-arm. The relative tracking algorithm measured relative translation position changes with errors of less than 0.75% of the total distance travelled, and orientation with errors below 5% of the cumulative rotation. With an error-correction step incorporated, OPTIX achieved C-arm repositioning with translation errors of less than 1.10±0.07\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ 1.10 \pm 0.07 $$\end{document} mm and rotation errors of less than 0.17±0.02∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ 0.17 \pm 0.02^\circ $$\end{document}. A display based on the OPTIX measurements enabled consistent C-arm repositioning within 5 mm of a previously stored reference position. The system achieved clinically relevant accuracies and could result in a reduced need for scout images when re-acquiring a previous position. We believe that, if implemented in an operating room, OPTIX has the potential to reduce both operating time and harmful radiation exposure to patients and surgical staff.

[1]  E Stindel,et al.  Can computer-assisted surgery help restore leg length and offset during THA? A continuous series of 321 cases. , 2015, Orthopaedics & traumatology, surgery & research : OTSR.

[2]  Carolyn Anglin,et al.  Single-camera visual odometry to track a surgical X-ray C-arm base , 2017, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  Tobias Rudolph,et al.  Comparison of three optical tracking systems in a complex navigation scenario , 2010, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[4]  Derek D. Lichti,et al.  A FAST, ACCURATE AND EASY TO IMPLEMENT METHOD FOR POSE RECOGNITION OF AN INTRAMEDULLARY NAIL USING A TRACKED C-ARM , 2014 .

[5]  Jacques Bejui-Hugues,et al.  Conventional versus computer-navigated TKA: a prospective randomized study , 2017, Knee Surgery, Sports Traumatology, Arthroscopy.

[6]  M. Amini A fluoroscopy-based intraoperative tool for measuring alignments in spinal deformity correction surgery , 2016 .

[7]  Roberto Manduchi,et al.  Bilateral filtering for gray and color images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[8]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[9]  P. Messmer,et al.  Navigating the Fluoroscope's C-Arm Back into Position: An Accurate and Practicable Solution to Cut Radiation and Optimize Intraoperative Workflow , 2007, Journal of orthopaedic trauma.

[10]  Felix Matthews,et al.  Navigating the fluoroscope's C-arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow. , 2007 .

[11]  F. Schwab,et al.  Adult Spinal Deformity—Postoperative Standing Imbalance: How Much Can You Tolerate? An Overview of Key Parameters in Assessing Alignment and Planning Corrective Surgery , 2010, Spine.

[12]  G LoweDavid,et al.  Distinctive Image Features from Scale-Invariant Keypoints , 2004 .

[13]  Peter Messmer,et al.  The MEPUC concept adapts the c-arm fluoroscope to image-guided surgery , 2003, CARS.

[14]  Gabor Fichtinger,et al.  Automatic C-arm pose estimation via 2D/3D hybrid registration of a radiographic fiducial , 2011, Medical Imaging.

[15]  Gary R. Bradski,et al.  ORB: An efficient alternative to SIFT or SURF , 2011, 2011 International Conference on Computer Vision.

[16]  Wei Tian,et al.  Accuracy and postoperative assessment of pedicle screw placement during scoliosis surgery with computer‐assisted navigation: a meta‐analysis , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[17]  P. Messmer,et al.  The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery. , 2004 .

[18]  Michèle Touchette Artificial X-ray imaging system (AXIS) – design and evaluation on C-arm performance in operating room and educational settings , 2017 .

[19]  Yoshito Otake,et al.  An electromagnetic “Tracker-in-Table” configuration for X-ray fluoroscopy and cone-beam CT-guided surgery , 2012, International Journal of Computer Assisted Radiology and Surgery.

[20]  Lejing Wang,et al.  Long Bone X-Ray Image Stitching Using Camera Augmented Mobile C-Arm , 2008, MICCAI.

[21]  Shahram Amiri,et al.  A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging , 2014, International Journal of Computer Assisted Radiology and Surgery.

[22]  V. M. Zat︠s︡iorskiĭ Kinematics of human motion , 1998 .

[23]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..