Characteristics of rain penetration through a gravity ventilator used for natural ventilation.

Gravity ventilators rely simply on air buoyancy to extract air and are widely used to exhaust air contaminants and heat from workplaces using minimal energy. They are designed to maximize the exhaust flow rate, but the rain penetration sometimes causes malfunctioning. In this study, the characteristics of rain penetration through a ventilator were examined as a preliminary study to develop a ventilator with the maximum exhaust capacity while minimizing rain penetration. A model ventilator was built and exposed to artificial rain and wind. The paths, intensities and amounts of penetration through the ventilator were observed and measured in qualitative and quantitative fashions. In the first phase, the pathways and intensities of rain penetration were visually observed. In the second phase, the amounts of rain penetration were quantitatively measured under the different configurations of ventilator components that were installed based on the information obtained in the first-phase experiment. The effects of wind speed, grill direction, rain drainage width, outer wall height, neck height and leaning angle of the outer wall from the vertical position were analyzed. Wind speed significantly affected rain penetration. Under the low crosswind conditions, the rain penetration intensities were under the limit of detection. Under the high crosswind conditions, grill direction and neck height were the most significant factors in reducing rain penetration. The installation of rain drainage was also important in reducing rain penetration. The experimental results suggest that, with proper configurations of its components, a gravity ventilator can be used for natural ventilation without significant rain penetration problems.

[1]  V. I. Hanby,et al.  CFD modelling of natural displacement ventilation in an enclosure connected to an atrium , 2007 .

[2]  Gary R. Hunt,et al.  Pollutant flushing with natural displacement ventilation , 2006 .

[3]  Thierry Boulard,et al.  Effect of Vent Openings and Insect Screens on Greenhouse Ventilation , 2006 .

[4]  Hsin Yu,et al.  SE—Structures and Environment: Scale Model Analysis of Opening Effectiveness for Wind-induced Natural Ventilation Openings , 2002 .

[5]  S. Sanquer,et al.  Full size, model and numerical evaluations of the smoke ventilator aerodynamic efficiency:development and qualification , 2002 .

[6]  Gary R. Hunt,et al.  The fluid mechanics of natural ventilation—displacement ventilation by buoyancy-driven flows assisted by wind , 1999 .

[7]  Kjeld Svidt,et al.  Measurement and Simulation of Three-Dimensional Airflow in a Livestock Test Room with Two-Dimensional Boundary Conditions , 1999 .

[8]  Constantinos Kittas,et al.  Natural ventilation performance of six greenhouse and tunnel types , 1997 .

[9]  B. K. Ghosh Some effects of crosswind on ventilators , 1993 .

[10]  H. J. Gerhardt,et al.  Aerodynamic efficiency of smoke ventilators — comparison of measurements on full scale and model ventilators , 1993 .

[11]  H. J. Gerhardt,et al.  Ventilation and heat and smoke extraction from industrial buildings , 1988 .

[12]  L. J. Cralley,et al.  Industrial Ventilation. A Manual of Recommended Practice (3rd ed.) , 1955 .

[13]  Kim Tae Hyeung,et al.  Estimation of Ventilation rates for General Gravity Ventilator , 2002 .

[14]  Yuguo Li,et al.  Natural ventilation induced by combined wind and thermal forces , 2001 .

[15]  Howard D. Goodfellow,et al.  Advanced Design of Ventilation Systems for Contaminant Control , 1986 .