Characteristics of baseband digital signal transmission for intrabody communications

Intrabody communications (IBC) is a new physical layer outlined in the recently ratified IEEE 802.15.6 Wireless Body Area Network (WBAN) standard. This data communication method uses the human body itself as the signal propagation medium. It is significant to investigate the signal characteristics for baseband digital data transceiver design in IBC. In this paper, we present preliminary channel attenuation characteristics of a time division multiple access (TDMA) scheme implemented based on baseband digital signal transmission. A digital block implemented on a field-programmable gate array (FPGA) board as well as a digital Pulse Generator are employed as the IBC transmitters. The timeslot occupancy is simulated by adjusting the duty cycle of a square wave of varying frequencies. The measurements using FPGA indicate the signal attenuation of 32.76 and 27.82 dB at frequency of 10 and 25 MHz, respectively, for digital signals with 50% duty cycle. In addition, the attenuation of signal with 20% and 50% duty cycle at 50 MHz are 32.76 and 30.63 dB when Pulse Generator is used as the IBC transmitter. The variation of duty cycle in pulses was then used to simulate a time division multiplexed transmission scheme. It was observed that the attenuation decreases around 4.0 dB when data pulses are increasingly present from 1 to 5 timeslots. Therefore, digital baseband signals deployed in a time division multiplexed mode with higher timeslot occupancy leads to lower attenuation for IBC transmissions.

[1]  Koji Ishibashi,et al.  An Analysis of Interference Mitigation Capability of Low Duty-Cycle UWB Communications in the Presence of Wideband OFDM System , 2010, Wirel. Pers. Commun..

[2]  Yo-Sheng Lin,et al.  A 0.5-V Biomedical System-on-a-Chip for Intrabody Communication System , 2011, IEEE Transactions on Industrial Electronics.

[3]  Duck Gun Park,et al.  A novel system for intrabody communication: touch-and-play , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[4]  Wolfgang Fichtner,et al.  Signal Transmission by Galvanic Coupling Through the Human Body , 2010, IEEE Transactions on Instrumentation and Measurement.

[5]  Javier Reina-Tosina,et al.  A Comprehensive Study Into Intrabody Communication Measurements , 2013, IEEE Transactions on Instrumentation and Measurement.

[6]  Michael Faulkner,et al.  A Survey on Intrabody Communications for Body Area Network Applications , 2013, IEEE Transactions on Biomedical Engineering.

[7]  Hoi-Jun Yoo,et al.  A Low-Energy Crystal-Less Double-FSK Sensor Node Transceiver for Wireless Body-Area Network , 2012, IEEE Journal of Solid-State Circuits.

[8]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[9]  冷腾飞 A Human Body Communication Transceiver Based on On-Off Keying Modulation , 2011 .

[10]  Thoams Guthrie Zimmerman Personal area networks (PAN) : near-field intra-body communication , 1995 .

[11]  Akira Maeki,et al.  1-cc computer using UWB-IR for wireless sensor network , 2008, 2008 Asia and South Pacific Design Automation Conference.

[12]  Zhao Xu,et al.  Energy-Constrained Duty-Cycle Optimization for Wireless Implanted Communication Devices , 2012 .

[13]  Hoi-Jun Yoo,et al.  The Signal Transmission Mechanism on the Surface of Human Body for Body Channel Communication , 2012, IEEE Transactions on Microwave Theory and Techniques.

[14]  Yuichi Kado,et al.  Noise analysis for near-field intra-body communication systems , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[15]  Michael Oberle,et al.  Low power systems-on-chip for biomedical applications , 2002 .

[16]  Muhammad Irfan Kazim,et al.  An analog receiver front-end for capacitive body-coupled communication , 2012, NORCHIP 2012.