A MEMS Device Capable of Measuring Near-Field Thermal Radiation between Membranes
暂无分享,去创建一个
Jun Yu | Chong Feng | Zhenan Tang | Changyu Sun | Jun Yu | Zhenan Tang | Changyu Sun | Chong Feng
[1] Gang Chen,et al. Near-field radiative heat transfer between a sphere and a substrate , 2008, 0909.0784.
[2] Gang Chen,et al. Surface phonon polaritons mediated energy transfer between nanoscale gaps. , 2009, Nano letters.
[3] Pasqualina M. Sarro,et al. A silicon-silicon nitride membrane fabrication process for smart thermal sensors , 1994 .
[4] Jean-Jacques Greffet,et al. ENHANCED RADIATIVE HEAT TRANSFER AT NANOMETRIC DISTANCES , 2002, Proceeding of Heat Transfer and Transport Phenomena in Microscale.
[5] Masafumi Kimata,et al. Low-cost 320x240 uncooled IRFPA using a conventional silicon IC process , 1999, Defense, Security, and Sensing.
[6] Shanhong Xia,et al. An ac microcalorimeter for measuring specific heat of thin films , 2004, Microelectron. J..
[7] Tang Zhen-an,et al. A Novel CMOS Device Capable of Measuring Near-Field Thermal Radiation , 2012 .
[8] Y. Çengel. Heat Transfer: A Practical Approach , 1997 .
[9] Jean-Jacques Greffet,et al. Thermal radiation scanning tunnelling microscopy , 2006, Nature.
[10] Ching-Liang Dai,et al. Fabrication and Characterization of CMOS-MEMS Thermoelectric Micro Generators , 2010, Sensors.
[11] Pierre Temple-Boyer,et al. Realization and performance of thin SiO2/SiNx membrane for microheater applications , 1998 .
[12] Zhenan Tang,et al. Measurement of the Heat Capacity of Copper Thin Films Using a Micropulse Calorimeter , 2010 .
[13] Euisik Yoon,et al. A high fill-factor infrared bolometer using micromachined multilevel electrothermal structures , 1999 .
[14] Frédérick Mailly,et al. Anemometer with hot platinum thin film , 2001 .
[15] J. Parisi,et al. Heat transfer in ultrahigh vacuum scanning thermal microscopy , 1999 .
[16] Jean-Jacques Greffet,et al. Radiative heat transfer at the nanoscale , 2009 .
[17] Wolfgang Müller-Hirsch,et al. Near-field heat transfer in a scanning thermal microscope. , 2005, Physical review letters.
[18] Andrea Irace,et al. Measurement of thermal conductivity and diffusivity of single and multilayer membranes , 1999 .
[19] T. Tanaka,et al. Infrared focal plane array incorporating silicon IC process compatible bolometer , 1996 .
[20] C. M Hargreaves,et al. Anomalous radiative transfer between closely-spaced bodies , 1969 .
[21] R. A. Smith,et al. Book Reviews: The Detection and Measurement of Infra-Red Radiation , 1957 .
[22] Lu Hu,et al. Near-field Thermal Radiation Between Two Closely Spaced Glass Plates Exceeding Planck’s Blackbody Radiation Law , 2008 .
[23] Jinfeng Li,et al. A MicroPirani Pressure Sensor Based on the Tungsten Microhotplate in a Standard CMOS Process , 2009, IEEE Transactions on Industrial Electronics.
[24] J. Meseguer,et al. Thermal radiation heat transfer , 2012 .
[25] R. Carminati,et al. Surface electromagnetic waves thermally excited: Radiative heat transfer, coherence properties and Casimir forces revisited in the near field , 2005, physics/0504068.
[26] Rolf Möller,et al. Heat transfer between two metallic surfaces at small distances , 1994 .
[27] Li-Tian Liu,et al. Study on new structure uncooled a-Si microbolometer for infrared detection , 2007, Microelectron. J..
[28] Robert E. Higashi,et al. Monolithic two-dimensional arrays of micromachined microstructures for infrared applications , 1998, Proc. IEEE.
[29] C. L. Tien,et al. MEASUREMENTS OF THERMAL RADIATION OF SOLIDS AT LIQUID-HELIUM TEMPERATURES , 1969 .
[30] C. L. Tien,et al. Experimental Investigation of Radiative Transfer Between Metallic Surfaces at Cryogenic Temperatures , 1970 .