Conductance probe for the measurement of liquid volume fraction and axial velocity in gas-liquid two phase flow

A conductance probe which can be used to measure parameters of gas-liquid two phase flow is designed and constructed in this paper. The proposed conductance probe consists of ring electrode pairs placed on the internal wall of a cylindrical test duct and can be applied to measure the liquid volume fraction and axial velocity in horizontal pipe simultaneously. The probe electrode geometry is designed based on the method of finite element analysis so that the regions of the gas-liquid mixture that are interrogated by the probe are optimal for the parameters measurement. The performance of the conductance probe is investigated experimentally with reference to stratified, annular and bubble phase distribution. In general, static calibration shows that this geometry of conductance probe has excellent linearity. The designed conductance probe will be further tested through the multiphase flow loop and examine its validity in the future work.

[1]  Marco Fossa,et al.  Design and optimisation of impedance probes for void fraction measurements , 2003 .

[2]  M W E Coney,et al.  The theory and application of conductance probes for the measurement of liquid film thickness in two-phase flow , 1973 .

[3]  Paolo Andreussi,et al.  An impedance method for the measurement of liquid hold-up in two-phase flow , 1988 .

[4]  A. Plaskowski,et al.  Cross Correlation Flowmeters, Their Design and Application , 1987 .

[5]  Gary Lucas,et al.  Measurement of the solids volume fraction and velocity distributions in solids–liquid flows using dual-plane electrical resistance tomography , 1999 .

[6]  Xingbin Liu,et al.  Conductance Sensor for Measurement of the Fluid Watercut and Flowrate in Production Wells , 2007 .

[7]  N. Jin,et al.  Design and geometry optimization of a conductivity probe with a vertical multiple electrode array for measuring volume fraction and axial velocity of two-phase flow , 2008 .

[8]  Margaritis Kostoglou,et al.  A conductance probe for measuring liquid fraction in pipes and packed beds , 1992 .

[9]  Feng Dong,et al.  Application of electrical resistance tomography to two-phase pipe flow parameters measurement , 2003 .

[10]  Feng Dong,et al.  The design of a dual-plane ERT system for cross correlation measurement of bubbly gas/liquid pipe flow , 2001 .

[11]  Marco Fossa,et al.  Design and performance of a conductance probe for measuring the liquid fraction in two-phase gas-liquid flows , 1998 .

[12]  Thomas J. Hanratty,et al.  Interfacial drag and film height for vertical annular flow , 1985 .

[13]  Gary Lucas,et al.  A six-electrode local probe for measuring solids velocity and volume fraction profiles in solids-water flows , 2000 .