Noninvasive measurement of rodent intraocular pressure with a rebound tonometer.

PURPOSE The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in conscious Wistar rats and in four different strains of mice. The effects of anesthesia on IOP were evaluated in two different strains of mice. RESULTS The IOP readings generated by the rebound tonometer correlated very well with the actual pressure in the eye. In rats, this linear correlation had a slope of 0.96 +/- 0.05 (mean +/- SEM, n = 4) and a Y-intercept of -2.1 +/- 1.2. In mice, the slope was 0.99 +/- 0.05 (n = 3), and the Y-intercept was 0.8 +/- 1.4. Using this method, the resting IOP of conscious male Wistar rats was observed to be 18.4 +/- 0.1 mm Hg (n = 132). In mice, strain differences in IOP were detected. Baseline IOP values in Balb/c, C57-BL/6, CBA, and 11- to 12-month-old DBA/2J mice were 10.6 +/- 0.6, 13.3 +/- 0.3, 16.4 +/- 0.3, and 19.3 +/- 0.4 mm Hg (n = 12), respectively. In separated studies, anesthesia lowered IOP from 14.3 +/- 0.9 to 9.2 +/- 0.5 mm Hg (n = 8) in C57-BL/6 mice, and from 16.6 +/- 0.4 to 9.4 +/- 0.6 mm Hg (n = 10) in CBA mice. CONCLUSIONS The rebound tonometer was easy to use and accurately measured IOP in rats and mice. This technique, together with advances in genetic and other biological studies in rodents, will be valuable in the further understanding of the etiology and pathology of glaucoma.

[1]  I. Pang,et al.  Measurement of mouse intraocular pressure with the Tono-Pen. , 2005, Experimental eye research.

[2]  I. Pang,et al.  Acute effects of glaucoma medications on rat intraocular pressure. , 2005, Experimental eye research.

[3]  Richard S. Smith,et al.  Genetically Increasing Myoc Expression Supports a Necessary Pathologic Role of Abnormal Proteins in Glaucoma , 2004, Molecular and Cellular Biology.

[4]  S. Thanos,et al.  Correlation between retinal ganglion cell death and chronically developing inherited glaucoma in a new rat mutant. , 2004, Experimental eye research.

[5]  Joseph M Harrison,et al.  Tonopen measurement of intraocular pressure in mice. , 2004, Experimental eye research.

[6]  Ronald L Gross,et al.  A mouse model of elevated intraocular pressure: retina and optic nerve findings. , 2003, Transactions of the American Ophthalmological Society.

[7]  P. Khaw,et al.  Novel anterior segment phenotypes resulting from forkhead gene alterations: evidence for cross-species conservation of function. , 2003, Investigative ophthalmology & visual science.

[8]  Young H. Kwon,et al.  Laser-induced mouse model of chronic ocular hypertension. , 2003, Investigative ophthalmology & visual science.

[9]  R. Weinreb,et al.  Ocular hypertension in mice with a targeted type I collagen mutation. , 2003, Investigative ophthalmology & visual science.

[10]  H. Quigley,et al.  Translimbal laser photocoagulation to the trabecular meshwork as a model of glaucoma in rats. , 2002, Investigative ophthalmology & visual science.

[11]  D. Goldblum,et al.  The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. , 2001, Experimental eye research.

[12]  Randy L. Johnson,et al.  Targeted Disruption of the Myocilin Gene (Myoc) Suggests that Human Glaucoma-Causing Mutations Are Gain of Function , 2001, Molecular and Cellular Biology.

[13]  L. Wheeler,et al.  Neuroprotection of retinal ganglion cells by brimonidine in rats with laser-induced chronic ocular hypertension. , 2001, Investigative ophthalmology & visual science.

[14]  B E Cohan,et al.  Measurement of intraocular pressure in awake mice. , 2001, Investigative ophthalmology & visual science.

[15]  Richard S. Smith,et al.  Intraocular pressure in genetically distinct mice: an update and strain survey , 2001, BMC Genetics.

[16]  M. Civan,et al.  Reliable measurement of mouse intraocular pressure by a servo-null micropipette system. , 2001, Investigative ophthalmology & visual science.

[17]  B E Cohan,et al.  Goldmann applanation tonometry in the conscious rat. , 2001, Investigative ophthalmology & visual science.

[18]  Michael G. Anderson,et al.  Genetic modification of glaucoma associated phenotypes between AKXD-28/Ty and DBA/2J mice , 2001, BMC Genetics.

[19]  J. Morrison,et al.  Effect of general anesthetics on IOP in rats with experimental aqueous outflow obstruction. , 2000, Investigative ophthalmology & visual science.

[20]  D Y Nishimura,et al.  Haploinsufficiency of the transcription factors FOXC1 and FOXC2 results in aberrant ocular development. , 2000, Human molecular genetics.

[21]  A. Kontiola,et al.  A new induction-based impact method for measuring intraocular pressure. , 2000, Acta ophthalmologica Scandinavica.

[22]  K. Yaoeda,et al.  Experimental glaucoma model in the rat induced by laser trabecular photocoagulation after an intracameral injection of India ink. , 1998, Japanese journal of ophthalmology.

[23]  V. Sheffield,et al.  The forkhead transcription factor gene FKHL7 is responsible for glaucoma phenotypes which map to 6p25 , 1998, Nature Genetics.

[24]  T H Roderick,et al.  Essential iris atrophy, pigment dispersion, and glaucoma in DBA/2J mice. , 1998, Investigative ophthalmology & visual science.

[25]  A. Kontiola,et al.  A new electromechanical method for measuring intraocular pressure , 1997, Documenta Ophthalmologica.

[26]  V. Sheffield,et al.  Identification of a Gene That Causes Primary Open Angle Glaucoma , 1997, Science.

[27]  H. Quigley Number of people with glaucoma worldwide. , 1996, The British journal of ophthalmology.

[28]  A. Warbritton,et al.  Glaucoma in food-restricted and ad libitum-fed DBA/2NNia mice. , 1995, Laboratory animal science.

[29]  S. Sharma,et al.  Chronic ocular hypertension following episcleral venous occlusion in rats. , 1995, Experimental eye research.

[30]  J. Morrison,et al.  Noninvasive measurement of rat intraocular pressure with the Tono-Pen. , 1993, Investigative ophthalmology & visual science.

[31]  A. Wurm,et al.  Overexpression and properties of wild-type and Tyr437His mutated myocilin in the eyes of transgenic mice. , 2005, Investigative ophthalmology & visual science.

[32]  S. John,et al.  Intraocular pressure in inbred mouse strains. , 1997, Investigative ophthalmology & visual science.

[33]  C. Meshul,et al.  A rat model of chronic pressure-induced optic nerve damage. , 1997, Experimental eye research.