Non-invasive temperature profile estimation in a lossy medium based on multi-band radiometric signals sensed by a microwave dual-purpose body-contacting antenna

Microwave radiometry has during the past two decades been investigated as a non-invasive scheme for measurement of subcutaneous tissue temperatures, basically for monitoring and control in hyperthermic treatment of cancer. In this effort, we test a contact-type, dual-purpose antenna with integral water bolus. To overcome conflicting optimization criteria in the integration of this thermometry technique with heat applicators exhibiting a large effective field size during superficial hyperthermia, a stacked configuration design is proposed, where the radiometer receive antenna (Archimedean spiral) is located on the front (skin) surface of the water bolus and the heating antenna (Dual-Concentric Conductor aperture) is placed on the bolus back surface. The motivation is to achieve homogeneous tissue heating simultaneously with non-invasive thermography of the target tissue under the applicator. This paper addresses the feasibility of predicting one-dimensional depth temperature profiles from multi-band brightness temperatures. The performance is investigated statistically by a Monte Carlo technique on both simulated and real heated-phantom data using up to six radiometric bands. Analysis of measured data shows that during the transient heating period in a solid lossy phantom, the inversion technique exhibits a precision (2 † T ) and skewness (bias) of estimated compared to actual temperature profiles of better than - 0.38°C and - 0.55°C, respectively.

[1]  T L Phillips,et al.  Combining hyperthermia and radiation: how beneficial? , 1991, Oncology.

[2]  Paul R. Stauffer,et al.  Multifrequency radiometric determination of temperature profiles in a lossy homogeneous phantom using a dual-mode antenna with integral water bolus , 2002 .

[3]  Piero Tognolatti,et al.  Temperature Reconstructions in a Dielectric Cylinder by Multi-Frequency Microwave Radiometry , 1993 .

[4]  T. Samulski,et al.  Spiral microstrip hyperthermia applicators: technical design and clinical performance. , 1990, International journal of radiation oncology, biology, physics.

[5]  A. Edwards,et al.  Feasibility of noninvasive measurement of deep brain temperature in newborn infants by multifrequency microwave radiometry , 2000 .

[6]  B. Bocquet,et al.  Non-invasive microwave radiometry thermometry , 1998, Physiological measurement.

[7]  Chris J. Diederich,et al.  Dual Concentric Conductor Radiator for Microwave Hyperthermia with Improved Field Uniformity to Periphery of Aperture , 1995 .

[8]  Michimasa Ito,et al.  Multifrequency Microwave Radiometry for Non-Invasive Thermometry Using a New Temperature Profile Model Function , 1995 .

[9]  Y Zhang,et al.  On the accuracy of noninvasive thermometry using molecular diffusion magnetic resonance imaging. , 1992, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[10]  A. Guy,et al.  Formulas for preparing phantom muscle tissue at various radiofrequencies. , 1984, Bioelectromagnetics.

[11]  J Crezee,et al.  Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometry. , 1993, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[12]  R. Kaul,et al.  Microwave engineering , 1989, IEEE Potentials.

[13]  D. Kapp,et al.  Efficacy of adjuvant hyperthermia in the treatment of superficial recurrent breast cancer: confirmation and future directions. , 1996, International journal of radiation oncology, biology, physics.

[14]  P. Stauffer,et al.  Radiation patterns of dual concentric conductor microstrip antennas for superficial hyperthermia , 1998, IEEE Transactions on Biomedical Engineering.

[15]  F. Hamprecht Introduction to Statistics , 2022 .

[16]  P. Fessenden,et al.  Body conformable 915 MHz microstrip array applicators for large surface area hyperthermia , 1992, IEEE Transactions on Biomedical Engineering.

[17]  R. Seip,et al.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound , 1995, IEEE Transactions on Biomedical Engineering.

[18]  P R Stauffer,et al.  Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia, a theoretical investigation. , 2000, Medical physics.

[19]  Paul R. Stauffer,et al.  Transceiving antenna for homogeneous heating and radiometric thermometry during hyperthermia , 2000 .

[20]  Robert N. McDonough,et al.  Detection of signals in noise , 1971 .

[21]  Svein K. Jacobsen,et al.  Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease , 2000, IEEE Transactions on Biomedical Engineering.

[22]  P. Stauffer,et al.  Performance Evaluation of Various Antenna Configurations for Microwave Thermography During Superficial Hyperthermia , 2001 .

[23]  Paul R. Stauffer,et al.  Improved Spatial Resolution in Thermography Obtained By a Two-Layered Structure of Microstrip Spirals , 1999 .

[24]  Svein Jacobsen Statistics of Leakage-Influenced Squared Coherence Estimated by Bartlett's and Welch's Procedures , 1993, IEEE Trans. Signal Process..

[25]  Jordi Joan Mallorquí Franquet,et al.  Non-invasive active thermometry with a microwave tomographic scanner in hyperthermia treatments in hyperthermia treatments , 1992 .

[26]  Stephen A. Dyer,et al.  Digital signal processing , 2018, 8th International Multitopic Conference, 2004. Proceedings of INMIC 2004..

[27]  J. van der Zee,et al.  Comparison of the clinical effectiveness of the 433 MHz Lucite cone applicator with that of a conventional waveguide applicator in applications of superficial hyperthermia. , 1999, International journal of radiation oncology, biology, physics.

[28]  Paul R. Stauffer,et al.  Characterization of a Tranceiving Antenna Concept for Microwave Heating and Thermometry of Superficial Tumors - Abstract , 1998 .

[29]  D Machin,et al.  Radiotherapy with or without hyperthermia in the treatment of superficial localized breast cancer: results from five randomized controlled trials. International Collaborative Hyperthermia Group. , 1996, International journal of radiation oncology, biology, physics.

[30]  Toshifumi Sugiura,et al.  Retrieval of temperature-depth profiles in biological objects from multi-frequency microwave radiometric data , 1993 .