Sulfur recirculation for increased electricity production in Waste-to-Energy plants.

Sulfur recirculation is a new technology for reducing boiler corrosion and dioxin formation. It was demonstrated in full-scale tests at a Waste to Energy plant in Göteborg (Sweden) during nearly two months of operation. Sulfur was recirculated as sulfuric acid from the flue gas cleaning back to the boiler, thus creating a sulfur loop. The new technology was evaluated by extensive measurement campaigns during operation under normal conditions (reference case) and operation with sulfur recirculation. The chlorine content of both fly ash and boiler ash decreased and the sulfur content increased during the sulfur recirculation tests. The deposit growth and the particle concentration decreased with sulfur recirculation and the dioxin concentration (I-TEQ) of the flue gas was reduced by approximately 25%. Sulfuric acid dew point measurements showed that the sulfuric acid dosage did not lead to elevated SO3 concentrations, which may otherwise induce low temperature corrosion. In the sulfur recirculation corrosion probe exposures, the corrosion rate decreased for all tested materials (16Mo3, Sanicro 28 and Inconel 625) and material temperatures (450 °C and 525 °C) compared to the reference exposure. The corrosion rates were reduced by 60-90%. Sulfur recirculation prevented the formation of transition metal chlorides at the metal/oxide interface, formation of chromate and reduced the presence of zinc in the corrosion products. Furthermore, measured corrosion rates at 525 °C with sulfur recirculation in operation were similar or lower compared to those measured at 450 °C material temperature in reference conditions, which corresponds to normal operation at normal steam temperatures. This implies that sulfur recirculation allows for higher steam data and electricity production without increasing corrosion.

[1]  J. Svensson,et al.  The Effects of KCl, K2SO4 and K2CO3 on the High Temperature Corrosion of a 304-Type Austenitic Stainless Steel , 2011 .

[2]  J. Svensson,et al.  Is KCl(g) Corrosive at Temperatures Above its Dew Point? Influence of KCl(g) on Initial Stages of the High Temperature Corrosion of 11% Cr Steel at 600°C , 2004 .

[3]  B. Steenari,et al.  Two strategies to reduce gaseous KCl and chlorine in deposits during biomass combustion — injection of ammonium sulphate and co-combustion with peat , 2013 .

[4]  Peter Arendt Jensen,et al.  The Effects of Ca-based Sorbents on Sulfur Retention in Bottom Ash from Grate-fired Annual Biomass , 2006 .

[5]  Larry L. Baxter,et al.  Boiler deposits from firing biomass fuels , 1996 .

[6]  J. Aurell Effects of Varying Combustion Conditions on PCDD/F Formation , 2008 .

[7]  J. Svensson,et al.  KCl-induced high temperature corrosion of the austenitic Fe–Cr–Ni alloys 304L and Sanicro 28 at 600 °C , 2006 .

[8]  Peter Glarborg,et al.  Mechanism and modeling of the formation of gaseous alkali sulfates , 2005 .

[9]  K. Iisa,et al.  Sulfation of potassium chloride at combustion conditions , 1999 .

[10]  B. Leckner,et al.  Countermeasures against alkali-related problems during combustion of biomass in a circulating fluidized bed boiler , 2008 .

[11]  J. Svensson,et al.  The high temperature oxidation of 11% chromium steel: Part I - Influence of pH2O , 2002 .

[12]  Mikko Hupa,et al.  Fouling tendency of ash resulting from burning mixtures of biofuels. Part 1: Deposition rates , 2006 .

[13]  J. Svensson,et al.  Fireside Corrosion of Stainless and Low Alloyed Steels in a Waste-Fired CFB Boiler; The Effect of Adding Sulphur to the Fuel , 2008 .

[14]  P. A. Jensen,et al.  Alkali/chloride release during refuse incineration on a grate: Full-scale experimental findings , 2008 .

[15]  Roger D. Griffin,et al.  A new theory of dioxin formation in municipal solid waste combustion , 1986 .

[16]  M. Hupa,et al.  Fouling tendency of ash resulting from burning mixtures of biofuels. Part 2: Deposit chemistry , 2006 .

[17]  Jan-Erik Svensson,et al.  KCl Induced Corrosion of a 304-type Austenitic Stainless Steel at 600°C; The Role of Potassium , 2005 .

[18]  J. Fick,et al.  Effects of sulfur on PCDD/F formation under stable and transient combustion conditions during MSW incineration. , 2009, Chemosphere.

[19]  M. Hupa,et al.  Fouling Tendency of Ash Resulting From Burning Mixtures of Biofuels , 2005 .

[20]  C. W. Lee,et al.  Experimental study on the effect of SO2 on PCDD/F emissions: determination of the importance of gas-phase versus solid-phase reactions in PCDD/F formation. , 2006, Environmental science & technology.

[21]  Jan-Erik Svensson,et al.  Indication of Chromium Oxide Hydroxide Evaporation During Oxidation of 304L at 873 K in the Presence of 10% Water Vapor , 1999 .

[22]  J. Svensson,et al.  Investigation of Chromium Volatilization from FeCr Interconnects by a Denuder Technique , 2010 .

[23]  R. L. Lindbauer,et al.  Combustion dioxin supression in municipal solid waste incineration with sulphur additives , 1992 .

[24]  J. Svensson,et al.  The influence of small amounts of KCl(s) on the high temperature corrosion of a Fe‐2.25Cr‐1Mo steel at 400 and 500°C , 2011 .

[25]  J. Svensson,et al.  An ESEM in situ investigation of initial stages of the KCl induced high temperature corrosion of a Fe–2.25Cr–1Mo steel at 400 °C , 2011 .

[26]  J. Svensson,et al.  Influence of SO2 on the Oxidation of 304L Steel in O2 + 40%H2O at 600 °C , 2008 .

[27]  John G. Olsson,et al.  Alkali Metal Emission during Pyrolysis of Biomass , 1997 .

[28]  P. Glarborg,et al.  An exploratory study of alkali sulfate aerosol formation during biomass combustion , 2008 .

[29]  A. Nordin,et al.  Sulfation of corrosive alkali chlorides by ammonium sulfate in a biomass fired CFB boiler , 2007 .

[30]  J. Svensson,et al.  Microstructural investigation of the breakdown of the protective oxide scale on a 304 steel in the presence of oxygen and water vapour at 600 °C , 2006 .

[31]  B. Gullett,et al.  Importance of chlorine speciation on de novo formation of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans. , 2003, Environmental Science and Technology.

[32]  P. Sjövall,et al.  Effect of sulphur containing additive on initial corrosion of superheater tubes in waste fired boiler , 2009 .

[33]  Helmut Seifert,et al.  Formation of PCDD/F during start-up of MSWI , 2003 .

[34]  Johanna Aurell,et al.  Effects of varying combustion conditions on PCDD/F emissions and formation during MSW incineration. , 2009, Chemosphere.

[35]  Moo Been Chang,et al.  Reducing PCDD/F formation by adding sulfur as inhibitor in waste incineration processes. , 2006, The Science of the total environment.

[36]  D. James Continuous monitoring. , 1979, The Urologic clinics of North America.

[37]  J. Svensson,et al.  The Influence of KCl on the Corrosion of an Austenitic Stainless Steel (304L) in Oxidizing Humid Conditions at 600 °C: A Microstructural Study , 2009 .

[38]  James E. Dunn,et al.  Effect of cofiring coal on formation of polychlorinated dibenzo-p-dioxins and dibenzofurans during waste combustion , 2000 .

[39]  A. Robinson,et al.  Pilot-Scale Investigation of the Influence of Coal−Biomass Cofiring on Ash Deposition , 2002 .

[40]  Helmut Seifert,et al.  Reduction of PCDD/F Formation in MSWI by a Process-Integrated SO2 Cycle , 2007 .

[41]  H. Ogawa,et al.  Dioxin reduction by sulfur component addition , 1996 .

[42]  Bo G Leckner,et al.  Properties of Particles in the Fly Ash of a Biofuel-Fired Circulating Fluidized Bed (CFB) Boiler , 2008 .

[43]  J. Svensson,et al.  The Influence of Sulfur Additions on the Corrosive Environments in a Waste-Fired CFB Boiler , 2006 .

[44]  B. Gullett,et al.  Effect of sulfur dioxide on the formation mechanism of polychlorinated dibenzodioxin and dibenzofuran in municipal waste combustors , 1992 .