Prospective gating control for highly efficient cardio-respiratory synchronised short and constant TR MRI in the mouse

Purpose Cardiac and respiratory motion derived image artefacts are reduced when data are acquired with cardiac and respiratory synchronisation. Where steady state imaging techniques are required in small animals, synchronisation is most commonly performed using retrospective gating techniques but these invoke an inherent time penalty. This paper reports the development of prospective gating techniques for cardiac and respiratory motion desensitised MRI with significantly reduced minimum scan time compared to retrospective gating. Methods Prospective gating incorporating the automatic reacquisition of data corrupted by motion at the entry to each breath was implemented in short TR 3D spoiled gradient echo imaging. Motion sensitivity was examined over the whole mouse body for scans performed without gating, with respiratory gating, and with cardio-respiratory gating. The gating methods were performed with and without automatic reacquisition of motion corrupted data immediately after completion of the same breath. Prospective cardio-respiratory gating, with acquisition of 64 k-space lines per cardiac R-wave, was used to enable whole body DCE-MRI in the mouse. Results Prospective cardio-respiratory gating enabled high fidelity steady state imaging of physiologically mobile organs such as the heart and lung. The automatic reacquisition of data corrupted by motion at the entry to each breath minimised respiratory motion artefact and enabled a highly efficient data capture that was adaptive to changes in the inter-breath interval. Prospective cardio-respiratory gating control enabled DCE-MRI to be performed over the whole mouse body with the acquisition of successive image volumes every 12–15 s at 422 μm isotropic resolution. Conclusions Highly efficient cardio-respiratory motion desensitised steady state MRI can be performed in small animals with prospective synchronisation, centre-out phase-encode ordering, and the automatic reacquisition of data corrupted by motion at the entry to each breath. The method presented is robust against spontaneous changes in the breathing rate. Steady state imaging with prospective cardio-respiratory gating is much more efficient than with retrospective gating, and enables the examination of rapidly changing systems such as those found when using DCE-MRI.

[1]  Nikola Cesarovic,et al.  Isoflurane and sevoflurane provide equally effective anaesthesia in laboratory mice , 2010, Laboratory animals.

[2]  S. Neubauer,et al.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields , 2004, Journal of magnetic resonance imaging : JMRI.

[3]  Mark Griswold,et al.  Rapid T1 mapping of mouse myocardium with saturation recovery look‐locker method , 2010, Magnetic resonance in medicine.

[4]  Christakis Constantinides,et al.  Effects of isoflurane anesthesia on the cardiovascular function of the C57BL/6 mouse. , 2011, ILAR journal.

[5]  M. L. Wood,et al.  Spoiling of transverse magnetization in steady‐state sequences , 1991, Magnetic resonance in medicine.

[6]  Jun Dazai,et al.  Retrospective gating for mouse cardiac MRI , 2006, Magnetic resonance in medicine.

[7]  Kieran Clarke,et al.  Fast, high‐resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system , 2003, Journal of magnetic resonance imaging : JMRI.

[8]  Raphael Sablong,et al.  An Optical Fiber-Based Gating Device for Prospective Mouse Cardiac MRI , 2014, IEEE Transactions on Biomedical Engineering.

[9]  Maher Sabbah,et al.  Real‐time gating system for mouse cardiovascular MR imaging , 2007, Magnetic resonance in medicine.

[10]  H. Hricak,et al.  Magnetic resonance imaging with respiratory gating: techniques and advantages. , 1984, AJR. American journal of roentgenology.

[11]  Stuart Gilchrist,et al.  A resistive heating system for homeothermic maintenance in small animals , 2015, Magnetic resonance imaging.

[12]  Klaas Nicolay,et al.  High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function , 2013, Magnetic resonance in medicine.

[13]  Brian J. Nieman,et al.  Three‐dimensional, in vivo MRI with self‐gating and image coregistration in the mouse , 2009, Magnetic resonance in medicine.

[14]  Klaas Nicolay,et al.  Comparison between prospective and retrospective triggering for mouse cardiac MRI , 2007, NMR in biomedicine.

[15]  Sean Smart,et al.  Whole body T1 mapping of small animals using prospective gating and variable flip angle imaging , 2016 .

[16]  Daniel R Thedens,et al.  Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance , 2009, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[17]  R. Kreis,et al.  Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences , 1999, Magnetic resonance in medicine.

[18]  Pierre Croisille,et al.  Cardiac and respiratory double self‐gated cine MRI in the mouse at 7 T , 2006, Magnetic resonance in medicine.