Monitoring performance and efficiency of photovoltaic parks

An approach allowing the on-target computation of efficiency and yield of large (hundreds of kW), grid-connected photovoltaic (PV) parks is presented. An efficiency metric is used to trigger alarms and to plan maintenance interventions. An accurate simulation model of the system, that is capable of taking into account all relevant environmental variables, has been used to precisely determine the expected baseline performances. Measured and simulated power together with string current data are constantly updated and monitored and then processed by using a novel figure of merit (FOM), to define aggregate efficiency indices both at the overall park level and at single string level. Aggregate indices on strings narrow down the search for sub-performing elements and allow the determination, possibly in one day, of whether the entire PV system or one of its components is not performing as expected. A workflow based on this approach is introduced along with some case studies attesting its effectiveness.

[1]  E. Skoplaki,et al.  A simple correlation for the operating temperature of photovoltaic modules of arbitrary mounting , 2008 .

[2]  J. Michalsky,et al.  Modeling daylight availability and irradiance components from direct and global irradiance , 1990 .

[3]  F. Bizzarri,et al.  Model of Photovoltaic Power Plants for Performance Analysis and Production Forecast , 2013, IEEE Transactions on Sustainable Energy.

[4]  B. Lehman,et al.  Decision tree-based fault detection and classification in solar photovoltaic arrays , 2012, 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[5]  Angelo Brambilla,et al.  Perturb and Observe Digital Maximum Power Point Tracker for Satellite Applications , 2002 .

[6]  Bin-Juine Huang,et al.  Solar cell junction temperature measurement of PV module , 2011 .

[7]  F. Pai,et al.  Performance Evaluation of Parabolic Prediction to Maximum Power Point Tracking for PV Array , 2011, IEEE Transactions on Sustainable Energy.

[8]  A. D. Jones,et al.  A thermal model for photovoltaic systems , 2001 .

[9]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[10]  B. Lehman,et al.  Outlier detection rules for fault detection in solar photovoltaic arrays , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[11]  Ruchi Singh,et al.  Incorporation of NREL Solar Advisor Model Photovoltaic Capabilities with GridLAB-D , 2012 .

[12]  P. Pinceti,et al.  Innovative solutions for photovoltaic plants remote monitoring , 2012, 2012 9th International Conference on Remote Engineering and Virtual Instrumentation (REV).

[13]  Michel Journée,et al.  Improving the spatio-temporal distribution of surface solar radiation data by merging ground and satellite measurements , 2010 .

[14]  R. A. Shayani,et al.  A New Index for Absolute Comparison of Standalone Photovoltaic Systems Installed at Different Locations , 2011, IEEE Transactions on Sustainable Energy.

[15]  Soumitro Banerjee,et al.  Simulation of Real World Circuits: Extending Conventional Analysis Methods to Circuits Described by Heterogeneous Languages , 2014, IEEE Circuits and Systems Magazine.

[16]  F. Bizzarri,et al.  Modeling and estimating yield and efficiency of photovoltaic solar parks , 2013, 2013 IEEE International Conference on Industrial Technology (ICIT).

[17]  H. G. Beyer,et al.  Data sets for energy rating of photovoltaic modules , 2013 .

[18]  Gilles Notton,et al.  Calculation of the polycrystalline PV module temperature using a simple method of energy balance , 2006 .

[19]  J. L. Balenzategui,et al.  Estimation of photovoltaic module yearly temperature and performance based on Nominal Operation Cell Temperature calculations , 2004 .

[20]  Emmanuel Kymakis,et al.  Performance analysis of a grid connected photovoltaic park on the island of Crete , 2009 .

[21]  E. Skoplaki,et al.  Operating temperature of photovoltaic modules: A survey of pertinent correlations , 2009 .

[22]  G. Schubert,et al.  Modeling hourly electricity generation from PV and wind plants in Europe , 2012, 2012 9th International Conference on the European Energy Market.

[23]  A. Premoli,et al.  Electrothermal oscillations of a PN junction operating in avalanche breakdown region , 1999, IEEE Electron Device Letters.

[24]  Miguel Brito,et al.  Modeling the performance of low concentration photovoltaic systems , 2010 .

[25]  Detlev Heinemann,et al.  Monitoring and remote failure detection of grid-connected PV systems based on satellite observations , 2007 .

[26]  H. Beyer,et al.  Mapping the performance of PV modules, effects of module type and data averaging , 2010 .

[27]  Doron Shmilovitz,et al.  On the control of photovoltaic maximum power point tracker via output parameters , 2005 .

[28]  Michal Tutsch,et al.  Using automated evaluation of efficiency for photovoltaic power plant , 2011, ETFA2011.