Development of Wearable Sheet-Type Shear Force Sensor and Measurement System that is Insusceptible to Temperature and Pressure

A sheet-type shear force sensor and a measurement system for the sensor were developed. The sensor has an original structure where a liquid electrolyte is filled in a space composed of two electrode-patterned polymer films and an elastic rubber ring. When a shear force is applied on the surface of the sensor, the two electrode-patterned films mutually move so that the distance between the internal electrodes of the sensor changes, resulting in current increase or decrease between the electrodes. Therefore, the shear force can be calculated by monitoring the current between the electrodes. Moreover, it is possible to measure two-dimensional shear force given that the sensor has multiple electrodes. The diameter and thickness of the sensor head were 10 mm and 0.7 mm, respectively. Additionally, we also developed a measurement system that drives the sensor, corrects the baseline of the raw sensor output, displays data, and stores data as a computer file. Though the raw sensor output was considerably affected by the surrounding temperature, the influence of temperature was drastically decreased by introducing a simple arithmetical calculation. Moreover, the influence of pressure simultaneously decreased after the same calculation process. A demonstrative measurement using the sensor revealed the practical usefulness for on-site monitoring.

[1]  C J Snijders,et al.  Shear stress measured on beds and wheelchairs. , 1997, Scandinavian journal of rehabilitation medicine.

[2]  L. Bennett,et al.  Shear vs pressure as causative factors in skin blood flow occlusion. , 1979, Archives of physical medicine and rehabilitation.

[3]  Wei-Hao Liao,et al.  Integrated ionic liquid-based electrofluidic circuits for pressure sensing within polydimethylsiloxane microfluidic systems. , 2011, Lab on a chip.

[4]  István Bársony,et al.  Three-dimensional force sensor by novel alkaline etching technique , 2005 .

[5]  L. Bennett,et al.  Skin blood flow in seated geriatric patients. , 1981, Archives of physical medicine and rehabilitation.

[6]  Emile Martincic,et al.  Flexible 3D Force Tactile Sensor for Artificial Skin for Anthropomorphic Robotic Hand , 2011 .

[7]  Chih-Ming Ho,et al.  A micromachined flow shear-stress sensor based on thermal transfer principles , 1999 .

[8]  W. Heerens Multi-terminal capacitor sensors , 1982 .

[9]  Chang Liu,et al.  Super flexible sensor skin using liquid metal as interconnect , 2007, 2007 IEEE Sensors.

[11]  I. Shimoyama,et al.  A shear stress sensor for tactile sensing with the piezoresistive cantilever standing in elastic material , 2006 .

[12]  Jan Vanfleteren,et al.  Two axis optoelectronic tactile shear stress sensor , 2012 .

[13]  D. Childress,et al.  Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. , 1993, Journal of rehabilitation research and development.

[14]  R. Patterson,et al.  Sitting forces and wheelchair mechanics. , 1990, Journal of rehabilitation research and development.

[15]  Taekeon Jung,et al.  Highly Stable Liquid Metal-Based Pressure Sensor Integrated with a Microfluidic Channel , 2015, Sensors.

[16]  Hongyu Yu,et al.  MEMS shear stress sensors for microcirculation , 2005 .

[17]  Yutaka Nonomura,et al.  Integration and packaging technology of MEMS-on-CMOS capacitive tactile sensor for robot application using thick BCB isolation layer and backside-grooved electrical connection , 2012 .

[18]  C. D. Mote,et al.  Development and calibration of a sub-millimeter three-component force sensor , 1997 .

[19]  J. Frenkel The Viscosity of Liquids. , 1930, Nature.

[20]  S M Dinsdale,et al.  Decubitus ulcers: role of pressure and friction in causation. , 1974, Archives of Physical Medicine and Rehabilitation.

[21]  Wen J. Li,et al.  An integrated MEMS three-dimensional tactile sensor with large force range , 2000 .

[22]  P. Dario,et al.  Characterization of a novel hybrid silicon three-axial force sensor , 2005 .

[23]  S M REICHEL,et al.  Shearing force as a factor in decubitus ulcers in paraplegics. , 1958, Journal of the American Medical Association.

[24]  Nan-Chyuan Tsai,et al.  Development of tactile sensors for simultaneous, detection of normal and shear stresses , 2010 .

[25]  Yong Xu,et al.  IC-integrated flexible shear-stress sensor skin , 2003 .

[26]  Susumu Watanabe,et al.  Effect of Rotational Axis Position of Wheelchair Back Support on Shear Force when Reclining , 2014, Journal of physical therapy science.

[27]  Isao Shimoyama,et al.  Stretchable liquid tactile sensor for robot-joints , 2010, 2010 IEEE International Conference on Robotics and Automation.