Quantitative magnetization transfer mapping of bound protons in multiple sclerosis

Quantitative analysis of magnetization transfer images has the potential to allow a more thorough characterization of the protons, both bound and free, in a tissue by extracting a number of parameters relating to the NMR properties of the protons and their local environment. This work develops previously presented techniques to produce estimates of parameters such as the bound proton fraction, f, and the transverse relaxation time of the bound pool, T2B, for the whole brain in a clinically acceptable imaging time. This is achieved by limiting the number of data collected (typically to 10); to collect 28 5‐mm slices with a reconstructed resolution of 0.94 × 0.94 mm. The protocol takes 82 sec per data point. The fitting technique is assessed against previous work and for fitting failures. Maps and analysis are presented from a group of seven controls and 20 multiple sclerosis patients. The maps show that the parameters are sensitive to tissue‐specific differences and can detect pathological change within lesions. Statistically significant differences in parameters such as T2B and f are seen between normal‐appearing white matter, multiple sclerosis lesions, and control white matter. Whole‐brain histograms of these parameters are also presented, showing differences between patients and controls. Magn Reson Med 50:83–91, 2003. © 2003 Wiley‐Liss, Inc.

[1]  G. Barker,et al.  Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times. , 2002, Magnetic resonance imaging.

[2]  Vasily L Yarnykh,et al.  Pulsed Z‐spectroscopic imaging of cross‐relaxation parameters in tissues for human MRI: Theory and clinical applications , 2002, Magnetic resonance in medicine.

[3]  James M Provenzale,et al.  Multiple sclerosis: diffusion tensor MR imaging for evaluation of normal-appearing white matter. , 2002, Radiology.

[4]  Jayaram K. Udupa,et al.  Magnetization Transfer Ratio Histogram Analysis of Normal-Appearing Gray Matter and Normal-Appearing White Matter in Multiple Sclerosis , 2002, Journal of computer assisted tomography.

[5]  G. B. Pike,et al.  Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI , 2001, Magnetic resonance in medicine.

[6]  J. Dehmeshki,et al.  Analysis of MTR histograms in multiple sclerosis using principal components and multiple discriminant analysis , 2001, Magnetic resonance in medicine.

[7]  G J Parker,et al.  Accurate multislice gradient echo T1 measurement in the presence of non‐ideal RF pulse shape and RF field nonuniformity , 2001, Magnetic resonance in medicine.

[8]  R. Henkelman,et al.  Magnetization transfer in MRI: a review , 2001, NMR in biomedicine.

[9]  R Stollberger,et al.  A comparison of magnetization transfer ratio, magnetization transfer rate, and the native relaxation time of water protons related to relapsing-remitting multiple sclerosis. , 2000, AJNR. American journal of neuroradiology.

[10]  G. Barker,et al.  Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis , 2000, Journal of the Neurological Sciences.

[11]  P S Tofts,et al.  Magnetization transfer imaging. , 2000, Neuroimaging clinics of North America.

[12]  E. Tournier-Lasserve CACNA1A mutations , 1999, Neurology.

[13]  David H. Miller,et al.  A multicenter measurement of magnetization transfer ratio in normal white matter , 1999, Journal of magnetic resonance imaging : JMRI.

[14]  M Filippi,et al.  Comparison of MS clinical phenotypes using conventional and magnetization transfer MRI , 1999, Neurology.

[15]  J. McGowan,et al.  The physical basis of magnetization transfer imaging. , 1999, Neurology.

[16]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[17]  M W Weiner,et al.  A serial study of new MS lesions and the white matter from which they arise , 1998, Neurology.

[18]  V. Dousset,et al.  Magnetization transfer imaging in vivo of the rat brain at 4.7 T: Interpretation using a binary spin‐bath model with a superlorentzian lineshape , 1997, Magnetic resonance in medicine.

[19]  天野 康雄,et al.  骨髄病変に対する脂肪抑制法併用 magnetization transfer imaging の検討 , 1997 .

[20]  J K Udupa,et al.  Global volumetric estimation of disease burden in multiple sclerosis based on magnetization transfer imaging. , 1997, AJNR. American journal of neuroradiology.

[21]  A. Mackay,et al.  In vivo measurement of T2 distributions and water contents in normal human brain , 1997, Magnetic resonance in medicine.

[22]  G. B. Pike,et al.  Pulsed magnetization transfer contrast in gradient echo imaging: A two‐pool analytic description of signal response , 1996, Magnetic resonance in medicine.

[23]  J. Chai,et al.  Estimation of in vivo proton intrinsic and cross‐relaxation rates in human brain , 1996, Magnetic resonance in medicine.

[24]  S. Swanson,et al.  A three-component model for magnetization transfer. Solution by projection-operator technique, and application to cartilage. , 1996, Journal of magnetic resonance. Series B.

[25]  G. Barker,et al.  An interleaved sequence for accurate and reproducible clinical measurement of magnetization transfer ratio. , 1996, Magnetic resonance imaging.

[26]  C. Morrison,et al.  A Model for Magnetization Transfer in Tissues , 1995, Magnetic resonance in medicine.

[27]  Scott D. Swanson,et al.  Transient Decay of Longitudinal Magnetization in Heterogeneous Spin Systems under Selective Saturation. IV. Reformulation of the Spin-Bath-Model Equations by the Redfield-Provotorov Theory , 1994 .

[28]  R M Henkelman,et al.  Quantitative interpretation of magnetization transfer , 1993, Magnetic resonance in medicine.

[29]  Bob S. Hu,et al.  Pulsed magnetization transfer spin‐echo MR imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[30]  R I Grossman,et al.  Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging. , 1992, Radiology.

[31]  R. Balaban,et al.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo , 1989, Magnetic resonance in medicine.

[32]  E. Samulski,et al.  The measurement of cross-relaxation effects in the proton NMR spin-lattice relaxation of water in biological systems: Hydrated collagen and muscle☆ , 1978 .

[33]  Brian Ford,et al.  The nag library "machine" , 1977, SGNM.

[34]  S. Forsén,et al.  Study of Moderately Rapid Chemical Exchange Reactions by Means of Nuclear Magnetic Double Resonance , 1963 .