Diffusion imaging with prospective motion correction and reacquisition

A major source of artifacts in diffusion‐weighted imaging is subject motion. Slow bulk subject motion causes misalignment of data when more than one average or diffusion gradient direction is acquired. Fast bulk subject motion can cause signal dropout artifacts in diffusion‐weighted images and results in erroneous derived maps, e.g., fractional anisotropy maps. To address both types of artifacts, a fully automatic method is presented that combines prospective motion correction with a reacquisition scheme. Motion correction is based on the prospective acquisition correction method modified to work with diffusion‐weighted data. The images to reacquire are determined automatically during the acquisition from the imaging data, i.e., no extra reference scan, navigators, or external devices are necessary. The number of reacquired images, i.e., the additional scan duration can be adjusted freely. Diffusion‐weighted prospective acquisition correction corrects slow bulk motion well and reduces misalignment artifacts like image blurring. Mean absolute residual values for translation and rotation were <0.6 mm and 0.5°. Reacquisition of images affected by signal dropout artifacts results in diffusion maps and fiber tracking free of artifacts. The presented method allows the reduction of two types of common motion related artifacts at the cost of slightly increased acquisition time. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

[1]  P. Hagmann,et al.  Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[2]  Jeremy D. Schmahmann,et al.  Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers , 2008, NeuroImage.

[3]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[4]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[5]  Anders M. Dale,et al.  On-line automatic slice positioning for brain MR imaging , 2005, NeuroImage.

[6]  R. Luypaert,et al.  Motion artifacts reduction in DWI using navigator echoes: A robust and simple correction scheme , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[7]  Heidi Johansen-Berg,et al.  Using diffusion imaging to study human connectional anatomy. , 2009, Annual review of neuroscience.

[8]  R W Cox,et al.  Real‐time 3D image registration for functional MRI , 1999, Magnetic resonance in medicine.

[9]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[10]  Robert Turner,et al.  Selective averaging for the diffusion tensor measurement. , 2005, Magnetic resonance imaging.

[11]  Alexander Leemans,et al.  The B‐matrix must be rotated when correcting for subject motion in DTI data , 2009, Magnetic resonance in medicine.

[12]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[13]  Rj Ordidge,et al.  The use of intelligent re-acquisition to reduce scan time in MRI degraded by motion. , 1998 .

[14]  M. Moseley,et al.  Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging , 2004, Magnetic resonance in medicine.

[15]  Wei-Che Tseng,et al.  Optical head tracking for functional magnetic resonance imaging using structured light. , 2008, Journal of the Optical Society of America. A, Optics, image science, and vision.

[16]  Robin M Heidemann,et al.  High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisition , 2009, Magnetic resonance in medicine.

[17]  Karla L Miller,et al.  Nonlinear phase correction for navigated diffusion imaging , 2003, Magnetic resonance in medicine.

[18]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[19]  Bruce Fischl,et al.  Comparison of manual and automatic section positioning of brain MR images. , 2006, Radiology.

[20]  D. Le Bihan,et al.  Artifacts and pitfalls in diffusion MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[21]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[22]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[23]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[24]  Peter Jezzard,et al.  Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images. , 2005, Journal of magnetic resonance.

[25]  Y. Cohen,et al.  Structural information in neuronal tissue as revealed by q‐space diffusion NMR spectroscopy of metabolites in bovine optic nerve , 1999, NMR in biomedicine.

[26]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[27]  J. Dubois,et al.  Optimized diffusion gradient orientation schemes for corrupted clinical DTI data sets , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[28]  Oliver Speck,et al.  Advantages and limitations of prospective head motion compensation for MRI using an optical motion tracking device. , 2006, Academic radiology.

[29]  V. Wedeen,et al.  Halving imaging time of whole brain diffusion spectrum imaging and diffusion tractography using simultaneous image refocusing in EPI , 2009, Journal of magnetic resonance imaging : JMRI.

[30]  Oliver Speck,et al.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system , 2006, NeuroImage.

[31]  S Thesen,et al.  Prospective acquisition correction for head motion with image‐based tracking for real‐time fMRI , 2000, Magnetic resonance in medicine.

[32]  James G Pipe,et al.  Multishot diffusion‐weighted FSE using PROPELLER MRI , 2002, Magnetic resonance in medicine.

[33]  S. Brockstedt,et al.  Triggering in Quantitative Diffusion Imaging with Single-Shot EPI , 1999, Acta radiologica.

[34]  Robin M Heidemann,et al.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi‐slice imaging , 2005, Magnetic resonance in medicine.

[35]  R. Gonzalez,et al.  Diffusion-weighted MR imaging of the brain. , 2000, Radiology.

[36]  S. Skare,et al.  On the effects of gating in diffusion imaging of the brain using single shot EPI. , 2001, Magnetic resonance imaging.

[37]  Eun-Kee Jeong,et al.  Improvement of accuracy of diffusion MRI using real‐time self‐gated data acquisition , 2009, NMR in biomedicine.

[38]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[39]  G J Barker,et al.  Improved reduction of motion artifacts in diffusion imaging using navigator echoes and velocity compensation. , 2000, Journal of magnetic resonance.