Study on thermal performance of semi-transparent building-integrated photovoltaic glazings

This paper presents a one-dimensional transient heat transfer model, the Semi-transparent Photovoltaic module Heat Gain (SPVHG) model, for evaluating the heat gain of semi-transparent photovoltaic modules for building-integrated applications. The energy that is transmitted, absorbed and reflected in each element of the building-integrated photovoltaic (BIPV) modules such as solar cells and glass layers were considered in detail in the SPVHG model. Solar radiation model for inclined surface has been incorporated into the SPVHG model. The model is applicable to photovoltaic (PV) modules that have different orientations and inclinations. The annual total heat gain was evaluated by using the SPVHG model. The impacts of different parameters of the PV module were investigated. It was found that solar heat gain is the major component of the total heat gain. The area of solar cell in the PV module has significant effect on the total heat gain. However, the solar cell energy efficiency and the PV module's thickness have only a little influence on the total heat gain. The model was also validated by laboratory tests by using a calorimeter box apparatus and an adjustable solar simulator. The test results showed that the simulation model predicts the actual situation well.

[1]  Kamal Abdel Radi Ismail,et al.  U-values, optical and thermal coefficients of composite glass systems , 1998 .

[2]  Ha Herbert Zondag,et al.  The yield of different combined PV-thermal collector designs , 2003 .

[3]  C. O. Pedersen,et al.  An evaluation of inside surface heat balance models for cooling load calculations , 1997 .

[4]  Kamal Abdel Radi Ismail,et al.  Modeling and simulation of a simple glass window , 2003 .

[5]  Hongxing Yang,et al.  Energy performance simulation and experiments of different BIPV facades , 2003 .

[6]  R. Furler Angular Dependence of Optical Properties of Homogeneous Glasses , 1991 .

[7]  M. J. Palacios,et al.  A test method to evaluate the thermal performance of window glazings , 2000 .

[8]  C. H. Cox,et al.  Design considerations for flat-plate-photovoltaic/thermal collectors , 1985 .

[9]  D. Loveday,et al.  Convective heat transfer coefficients at a plane surface on a full-scale building facade , 1996 .

[10]  Takahiko Miyazaki,et al.  Energy savings of office buildings by the use of semi-transparent solar cells for windows , 2005 .

[11]  W. Beckman,et al.  Transmission of diffuse radiation through CPC and flat plate collector glazings , 1980 .

[12]  Tady Y Y Fung BEng MEng,et al.  Study on Optimum Inclination Angle of Solar Collecting Surface in Hong Kong , 2005 .

[13]  P. Lund,et al.  Daylight measurements and calculations with an a-Si photovoltaic solar facade , 2000 .

[14]  R. H. Marshall,et al.  Validation of heat transfer coefficients on interior building surfaces using a real-sized indoor test cell , 1990 .

[15]  Claudio A. Estrada,et al.  The thermal response of laminated glass with solar control coating , 1998 .

[16]  A. D. Jones,et al.  A thermal model for photovoltaic systems , 2001 .

[17]  W. L. Wong,et al.  Selection of an example weather year' for Hong Kong , 1993 .

[18]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[19]  Zahari Ibarahim,et al.  A validated model of naturally ventilated PV cladding , 2000 .

[20]  Ewa Radziemska,et al.  Thermal performance of Si and GaAs based solar cells and modules: a review , 2003 .