Assessment of the inhalation technique in outpatients with asthma or chronic obstructive pulmonary disease using a metered-dose inhaler or dry powder device.

Inhaled medication is commonly prescribed for the treatment of asthma and chronic obstructive pulmonary disease (COPD), but is often not properly used by patients. A total of 316 patients suffering from asthma or COPD took part in a study that evaluated how patients utilized their metered-dose inhaler (MDI) or dry powder inhaler, using a standardized inhaler checklist. Two hundred eighty-one patients (88.9%) made at least one mistake in the inhalation technique. The mistakes were classified into skill and nonskill mistakes. Two hundred patients made one or more skill mistakes and 81 patients only made one or more nonskill mistakes. The most common skill error was "not continuing to inhale slowly after activation of the canister" (69.6%). The nonskill item most patients had difficulties with was "exhale before the inhalation" (65.8%). Patients who used an MDI made significantly fewer nonskill mistakes than patients using a dry powder device. Older patients had more difficulty with the correct use of the inhaler than younger patients. There was no difference in errors between men and women. In this patient sample, most patients failed to use their inhaler correctly. Regular instructions and checkups of inhalation technique are the responsibility of the physician and should be a standard and routine procedure.

[1]  J. J. Klein,et al.  Evaluation of the effectiveness of four different inhalers in patients with chronic obstructive pulmonary disease. , 1995, Thorax.

[2]  S. L. Lawson Medical personnel's knowledge of and ability to use inhaling devices: Hanania NA, Wittman R, Kesten S, et al Chest 105:111–116 Jan 1994 , 1994 .

[3]  P. Zanon Inhalation anti-asthma therapy with spacers: technical aspects. , 1994, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[4]  T. Chinet,et al.  Inhaled therapy in asthma: metered-dose inhaler experience. , 1994, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[5]  A. Cartier,et al.  Patient handling of a multidose dry powder inhalation device for albuterol. , 1994, Chest.

[6]  K. Grathwohl,et al.  Misuse of metered-dose inhalers in hospitalized patients. , 1994, Chest.

[7]  D. M. Williams,et al.  Assessment of interrater and intrarater reliability in the evaluation of metered dose inhaler technique. , 1994, Chest.

[8]  N. Hanania,et al.  Medical personnel's knowledge of and ability to use inhaling devices. Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. , 1994, Chest.

[9]  B. Ekholm,et al.  Evaluation of conventional press-and-breathe metered-dose inhaler technique in 501 patients. , 1994, The Journal of asthma : official journal of the Association for the Care of Asthma.

[10]  N. Hanania,et al.  Medical Personnel's Knowledge of the Ability to Use Inhaling Devices , 1994 .

[11]  Sharp Jt,et al.  Use and acceptance of ventolin Rotacaps and the Rotahaler in 1235 asthmatic patients. , 1993 .

[12]  B. Hilman Aerosol deposition and delivery of therapeutic aerosols. , 1991, The Journal of asthma : official journal of the Association for the Care of Asthma.

[13]  A. Baas,et al.  [Dosage aerosols; problems with the inhalation technic]. , 1989, Nederlands tijdschrift voor geneeskunde.