Urine particle evaluation: a comparison between the UF-1000i and quantitative microscopy

Abstract Background: The study of urine particles plays a key role in the diagnosis of kidney diseases. In this study, the authors evaluated the correlation between the UF-1000i and quantitative manual microscopy. Methods: A total of 214 untreated urine samples were studied using the Sysmex UF-1000i and compared with results obtained from quantitative manual microscopy using the Fuchs-Rosenthal counting chamber. Results: Using Pearson statistics, we observed satisfactory correlation between the UF-1000i and quantitative microscopy: for red blood cells (RBCs) r was 0.98, for white blood cells (WBCs) r was 1.00, for epithelial cells (EC) r was 0.96, and for casts r was 0.69. Using linear regression statistics, we also observed satisfactory correlation between the UF-1000i and quantitative microscopy: for RBCs R2 was 0.95, for WBCs R2 was 0.99, for EC R2 was 0.92, and for casts R2 was 0.48. Conclusions: In our experience, automated urine particle analysis performed using the Sysmex UF-1000i analyzer is sufficiently precise and improves the workflow in a routine laboratory. Precision was satisfactory and concordance with the reference method is good for RBC, WBC and EC; for casts microscopic observation is required for flagged samples to discriminate hyaline from pathologic casts. Clin Chem Lab Med 2010;48:1107–11.

[1]  M. Ferrian,et al.  Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections. , 2009, Diagnostic microbiology and infectious disease.

[2]  M. Ferrian,et al.  Laboratory diagnosis of renal failure: urine conductivity and tubular function. , 2009, Minerva urologica e nefrologica = The Italian journal of urology and nephrology.

[3]  A. von Eckardstein,et al.  Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting , 2007, Clinical chemistry and laboratory medicine.

[4]  Jau-Tsuen Kao,et al.  Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy. , 2007, Clinica chimica acta; international journal of clinical chemistry.

[5]  Diane E Berry Turnaround time improvement and department-wide benefits of automation in urinalysis. , 2006, Clinical leadership & management review : the journal of CLMA.

[6]  P. Lamchiagdhase,et al.  Urine sediment examination: a comparison between the manual method and the iQ200 automated urine microscopy analyzer. , 2005, Clinica chimica acta; international journal of clinical chemistry.

[7]  A. Butch,et al.  Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers. , 2005, American journal of clinical pathology.

[8]  A. Regeniter,et al.  Standardisierte Partikelzählung im Urin: Ein Vergleich zwischen Durchfluss-Zytometrie, Zählkammer und traditionellem Urinsediment , 2004 .

[9]  G. Piccoli,et al.  Microscopic urinalysis and automated flow cytometry in a nephrology laboratory. , 2003, Clinical chemistry.

[10]  A. Huber,et al.  Quantitative urine particle analysis: integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber. , 2003, Clinical chemistry.

[11]  Z. Zaman,et al.  Safely reducing manual urine microscopy analyses by combining urine flow cytometer and strip results. , 2001, American journal of clinical pathology.

[12]  L. Risch,et al.  Urine analysis performed by flow cytometry: reference range determination and comparison to morphological findings, dipstick chemistry and bacterial culture results--a multicenter study. , 2001, Clinical nephrology.

[13]  W. Guder,et al.  The role of automated urine particle flow cytometry in clinical practice. , 2000, Clinica chimica acta; international journal of clinical chemistry.

[14]  Walter Hofmann,et al.  European Urinalysis Guidelines , 2000, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[15]  G. Filler,et al.  Reference values for neonates and children for the UF-100 urine flow cytometer. , 1999, Clinical chemistry.

[16]  R. Vuento,et al.  Evaluation of Sysmex UF-100 urine flow cytometer vs chamber counting of supravitally stained specimens and conventional bacterial cultures. , 1999, American journal of clinical pathology.

[17]  M. Sancho,et al.  Clinical laboratory automated urinalysis: comparison among automated microscopy, flow cytometry, two test strips analyzers, and manual microscopic examination of the urine sediments , 2008, Journal of clinical laboratory analysis.

[18]  V. Sathiyapriya,et al.  Increased glycation of hemoglobin and plasma proteins in normotensive, non-diabetic obese Indian subjects: putative role of lipid peroxides , 2007, Clinical chemistry and laboratory medicine.

[19]  A. Huber,et al.  [Standardized counting of particles in the urine: a comparison between flow cytometry, cell chamber counting and traditional sediment analysis]. , 2004, Praxis.

[20]  A. Eltom,et al.  Thyroglobulin in serum as an indicator of iodine status during pregnancy. , 2000, Scandinavian journal of clinical and laboratory investigation.